首页 SY-2000N发光定氮说明书(英文版)

SY-2000N发光定氮说明书(英文版)

举报
开通vip

SY-2000N发光定氮说明书(英文版)SY—2000N Chemiluminescent nitrogen detector Instructions for use (V2.0) 泰州市奥普特分析仪器有限公司 TaiZhou City AoPuTe Analysis Instruments Co. Ltd. Recording 1 Foreword : SY-2000N Chemiluminescent nitrogen detector based on principle of chemiluminescence method combined...

SY-2000N发光定氮说明书(英文版)
SY—2000N Chemiluminescent nitrogen detector Instructions for use (V2.0) 泰州市奥普特 分析 定性数据统计分析pdf销售业绩分析模板建筑结构震害分析销售进度分析表京东商城竞争战略分析 仪器有限公司 TaiZhou City AoPuTe Analysis Instruments Co. Ltd. Recording 1 Foreword : SY-2000N Chemiluminescent nitrogen detector based on principle of chemiluminescence method combined with computer technology to develop next-generation precision laboratory instruments. Wide linear range, strong anti-jamming ability, simple, stable and reliable results, and highlight the advantages, which can be widely applied in petroleum, chemical industry, electric power, coal, food, environmental protection and other areas, is now more advanced sulfur analysis instrument. 2 The basic principle : SY-2000N Chemiluminescent nitrogen detector works as follows: 1 : SY-2000N Chemiluminescent nitrogen detector block diagram Instrument by the injector, cracking, ozone generators, reactor micro-current amplifier and, photoelectric conversion device, data processing system consists of several parts. When the sample is introduced after high temperature pyrolysis reactor, mixed with oxygen combustion and quantification of nitrogen compounds into NO, dehydration and carried by carrier gas dryer into the reaction Chamber, from ozone O3 reaction excited NO2cm, Dang NO2 ﹡ When you return to the ground state, issue a photon, the light received by a photomultiplier tube and consists of micro-current amplifier, data processing systems convert the displayed a luminous intensity is proportional to the signal, by measurement of chemiluminescence intensity to derive the total nitrogen content of the sample. The entire reaction can be represented as follows:     High-temperature       R—N+O2 N O+NO 2 + CO 2 +H2O N O+ O3 NO2*+O2 N O2 * NO2 +hγ' 3 Detailed technical parameters 1 Technical parameters: 1.1 Power supply voltage:AC220 v±10% 1.2 Power of the whole machine ≤ 2200 W 1.3 Measuring range: 0.1ppm—1% 1.4 Detection limit: 2 NG 1.5 Repeatability: Content of 0.1 ppm--1.0ppm Shi ±0.1ppm Contents 1 ppm--10ppm Shi <10% Content >10 ppm Shi <5% 1.6 Baseline drift using : < 2uV/72h 1.7 Temperature range : room temperature ~1150 ° c 1.8 Temperature control accuracy: better than ±3° c 1.9 Cooling way: air cooler 4 Performance introduction 4 .1 Wide range of application , Applies to total stability of light hydrocarbon gas, light oil or heavy oil Sulfur Determination of the content of. 4 .2 Introduction of computer control and data processing. 4 .3 Equipped with a printer directly prints analysis, analysis maps. 4 .4 Instrument Dual CPU architecture functional, Performance and stability 、 Measuring accuracy of the results. 4 .5 Combination of single-point calibration and multi-point calibration, automatically generated, save the calibration curve. 4 .6 High measuring range (third gear attenuation). 4 .7 High sensitivity (gain four). 4 .8 Instrument software is simple, convenient, and easy to learn 。 5 System requirements 5.1 Environmental requirements: To ensure that the instruments can work properly, need to have the following environment conditions: 1. Ambient temperature constant and cannot be above 30degrees centigrade. 2. Must not contain corrosive gases in ambient air and dust, so as to avoid corrosion of parts, wiring short circuit. 3. Spacious, airy instrumentation requirements, avoid direct exposure to sunlight. 5.2 Power requirements: 1. Power supply voltage 220V±5%/50HZ . 2. Supply current is greater than 15A. 3. Have a good ground, resistance to ground is not more than 3ω. 5.3 Air source: 1. High purity oxygen: purity ≥ 99.9% 2. High-purity argon gas : purity ≥ 99.9% 6 Equipment composition and installation 6.1 Opening inspection: After receiving the instrument user, against the packing list should be examined case-by-case, see if there are parts shortages or damage occured, if there is a shortage or damage, should get in touch with the company. Note: before using this instrument, carefully read the instructions for all content, are familiar with the various components of the instrument, in order to avoid accidental operation damage the instrument, if service is required, it shall promptly notify the company. 6.2 System composition: 6.2.1 Hosts: 1, response splitting part: Complete sample sulphide is converted S O2 Reaction. By two-stage furnace computer control and display of temperature and the ambient temperature within the host, temperature control accuracy ±1%, flow control unit can control three way adjustment range is as follows: O2(cracked) 50 ~ 500 ml/min O2(gas) 30 ~ 300 ml/min A r (Carrier gas) 30 ~ 300 mL/min Part 2, detector Complete the detection of fluorescence signals, amplification, and accept the computer control, to send the signal to the computer. 6.2.2 Computer system comprising Computer systems including the host, monitor, printer, keyboard, mouse, and the corresponding computer software, dedicated data acquisition and control system. Complete temperature control, signal processing and control, intermediate and final results of the sample analysis. 6.2.3 Injector parts To ensure constant speed sampling, the user can 0.3 ul/sec ≈ 1.2 ul/sec Based on an analysis of requirements within the scope of selected sampling speed. 6.2.4 Pneumatic connections System air flow chart: 5 : System air flow chart Note: the instrument before use, clean all gas lines and fittings require. 1. Flow control valve clockwise, will all flow to a minimum. Note: do not close the flow control valve, you should gently go can feel when there is resistance to, too much force can damage the valve. 2 . Inner diameter of 3mm of stainless steel pipes, copper pipes or Teflon pipe imports argon argon gas source and host connected to source of oxygen and oxygen linked to imports. Note: requires source of oxygen with oxygen inlet connection between gas dryers (5A Molecular sieve). 3. quartz cracked pipe installation (1) Host activities on both sides of the bezel is removed. (2) Saturate a cotton small amounts of solvent such as alcohol or acetone will wipe clean the tube wall, to remove the dirt and fingerprints. (3) Carefully place the Lysis tubes in cracking furnaces, the injector at the right side of the stove. (4) Splitting oxygen pipeline connected to the Lysis tube cracking oxygen imported, gas pipeline connected to the Lysis tube containing gas imports. (5) With four semi-circular ring of insulating ceramic (Lysis tube clips) to the Lysis tube and left end fixed. Note: you should enable the Lysis tube coaxial with the cracking furnace inside as much as possible, to ensure that pipe heat evenly. (6) Crystal cracked fitting the Lysis tube trailer, and connected to the equipment of the gas export and fitting clamp fitting and the Lysis tube end clamp. Note: to ensure the Lysis tube type ball grinding and not leak between the connector, you need to use sealing washers (silicone rubber). (7) Will host activities on both sides of the bezel installed. 3. PTFE back panel of the pipeline will be connected to the gas-exporting and gas dryers, dryer with the host at the other end connected to the rear panel above the gas imports. More than pneumatic connection when the operation is complete, it is necessary to complete gas tightness check, to ensure that the gas leak, air flow has not stopped up, all gases from the exhaust only export outflows. 6.2.5 Electrical connection: 1. In the back panel of the instrument's good ground earth terminal access. 2. Plug the supplied power cord into the power socket on the rear panel corresponds to. 3. Connect the computer power cable in accordance with the operating instructions connect a computer system. Note: ensure all wiring connections and reliable, no loose. 7 Software installation and operating instructions 7.1 Install SY-2000N Program Installing for the first time, follow these steps ∶ 1 . Power boot a computer into windowsXP operating systems 2 . The CD Setup and installation considerations for copying to your hard drive c:\SY in a subdirectory 3. left mouse button double-click CD SETUP. EXEinto SY-2000N Setup. 4. Follow the instructions in Setup, each click (Next) button, and then clicking (Finish) button to complete the installation. Or basis directly from the CD Installation Notes install program. Note: the instrument is to give users in all application software is already installed, if the user is in use for some other reason you need to reinstall the SY-2000N program, you should uninstall the SY-2000N Setup and install SY-2000N Setup. How to uninstall please refer to uninstalling SY-2000N Setup. 7.2 Uninstall SY-2000N Setup Uninstall the SY-2000N Installer, follow these steps: 1 Open the WindowsXP [ Control Panel ], double-click [ add/territory remove programs ] icon, the system opens (adds HK remove programs) the dialog box. 2 In the dialog box list, select the "SY-2000N chemiluminescent nitrogen detector", and then click (add/territory remove) button, prompt box appears, select the "Yes" button to start the delete SY-2000N chemiluminescent nitrogen detector program, then press OK button to complete the uninstall. 8 Start and quit SY-2000N programs Overview Install SY-2000N program Uninstall SY-2000N program Start SY-2000N programs Quit SY-2000N programs SY-3000N Window and basic operation 8.1 Overview This chapter describes how to install the SY-2000N chemiluminescent nitrogen detector program. Prior please make sure Microsoft Windows XP or later is installed. If you do not use Windows menus, edit boxes, scroll bars, or dialog boxes you have questions, please refer to Windows XP operating system user's manual. Note:SY-2000N Installer Before installation, please keep it safe backup just in case. If you receive an upgraded version of the program, uninstall the original program , And then install the upgraded version of the program (See Uninstall SY-2000N programs). 8.2 Start You can select the method to enter: 1 , Double-click windowsXP desktop SY-2000N shortcut icon chemiluminescent nitrogen detector: 2、 Click the windowsXP began , and then move the mouse pointer to point to the program SY-2000N chemiluminescent nitrogen detector and its parent menu item under SY-2000N chemiluminescence nitrogen, and click the left mouse button on the menu. 8.3 Exit You can select the method exit 1. Select from the file menu (exit). 2. Quick on the button bar, click the close button. 9 Power on: In accordance with the instructions for use keep full equipment electricity, gas, ground connection is good, check for leakage, or leakage, make sure that is correct, and then follow these steps to power on the system. (1) Gas purging: To ensure the instrument often work under, power should be gas before blowing to remove water vapour and other impurities in the gas. This is a new instrument and the instrument is not used for a long time is particularly important. Gas purging method: flow control valve counterclockwise, moved three meters are to 15 Notches, purging 10 Minutes or so. ( 2 ) Power up Open the power distribution box, or total power supply distribution Board, reopening the entire instrument, instrument power up, boot the computer, enter the Windows The operating system. Note:  Enter SY-2000N Program cannot run other applications, has exited other applications should be running and shuts down. Windows window then click on Start , and settings , and Control Panel , and power management ,power schemes , and waiting for the State of the system , and turn off the monitor , And turn off hard disks , these four sets for the never option. Otherwise, theSY-2000N program may not run correctly to avoid damage to the instrument, such as over-temperature of cracking furnace, electric wire burned. ( 3 ) Gas flow selection ① Cracking O2 Airflow: This road O2 Gas flow rate directly affects the size of the sample of oxidative pyrolysis, effects samples into sulphide in SO2 conversion rates. Analysis when making cracking o2 gas in excess, to ensure full combustion of samples, Lysis tube does not generate carbon, while traffic also should not be too large, otherwise not conducive to the transformation of sulfides as SO2 responses, sample fluorescence intensity is reduced. General analysis of condition, can be cracked O2 Air flow adjustment to 150~500ml/min Within the scope of. ② Ar Airflow: Ar As the carrier gas, the volatile samples carry into the cracked pipe of high temperature parts, oxidative pyrolysis of samples. General requirements for Ar gas flow in the 60~400ml/min range, users can high and low sulfur content of samples, sample size and cracking of o2 gas flow, such as the size of the selection of suitable Ar gas flows. ③ O2 Airborne gas flow: General analysis of liquid samples of relatively light distillate, gas can be without this road. When the samples are less volatile, and Ar gas by adding a certain amount of o2 gas together as the carrier gas, can promote the gasification of the samples. ( 4 ) SY-2000N Program starts As mentioned earlier, run SY-2000N Program, enter the standard sample, sample analysis. 10 Sample analysis: Analysis of liquid samples, for example the following describes the basic operation of samples and some problems should be noticed. 1 . Sample preparation: Analysis unknown samples by fluorescence analysis of sulfur method, first get the response value of an unknown sample, namely integration area and sulfur content of unknown sample results are based on the same points of reference materials in the condition area, reference materials and sample weight of unknown, unknown score calculated data such as size of the sample. Therefore, prior to the analysis of unknown samples, to pre-select a number of different concentration of standard samples, sample selection should pay attention to the following several points:      (1) With suitable sulfur compounds as solute: (2) With the appropriate solvent, samples, and unknown samples in the sample matrix as close as possible. (3) Use within the warranty period of the standard sample, sample shelf life is one year, so that samples need to be kept. Solutes and solvents are volatile substances the samples should be kept in refrigerated containers, to prolong its service life. 2 . Sample analysis As mentioned before sample analysis, first select the appropriate sample, sample curve, the concentration of the samples in the standard curve, to ensure sample analysis data is accurate and reliable, if the concentration of the samples in the standard curve in addition to and exceed the minimum sample concentration 10%~20% , Or micro-current amplifier saturation (peak shape for flat peak, need to replace the quantum), asked to reselect the sample making standard curves. 11 Shutdown: Subject to the instrument after use, shut down by doing the following: 1 . Turn off the UV lamp power supply, cooling by temperature controller button, turn off the furnace power. 2 . Power down the host, injector, for a few minutes and pneumatic clean after, turn off the gas. 3 . For two hours, after the temperature dropped off fan switch. 4 . By balloon tips quit SY-2000N programs into Windows exit window, power off the computer, monitor, printer. 5 . Distribution box, or power Board total power is off. 12 Reaction chamber-cleaning Because the instrument used for a long time. Reaction indoor residue deposits, resulting in a lower sensitivity, analysis results are not repeated, so users should be based on the use of regular cleaning Chamber. The sediment may be powdered or likely to be oily, its color may be yellow, Brown or black, which mainly depends on the type and operating conditions of the analysis sample, such as material feed speed too high, lack of oxygen, the oven temperature is too low. Cleaning process is as follows: 1 . Turn off all power switches. 2 . Open the cover, unplug the darkroom high voltage power and signal plugs, disconnected lines. 3 . Release the dark base and back panel screws, take out the darkroom later, release the dark end cap fixing screws. (Air road pipelines of end caps). Note: photomultiplier tube-side window shows up, the needs in-side window with a piece of black cloth to block the light. 4 . Remove Chamber cover screws, carefully removing the gland, filters, Quartz. If the "o"-ring broken, replace it with new. 5 . Cleaned the mirrors of wadded paper with high silica film and filters, wipe with clean soft cloth with no hair reaction indoor wall, if necessary, get scrubbed clean with acetone or ethanol, and oxygen blow dry. 6 . Reaction chamber-cleaning is complete, again in order to install. Note: when fixed optical filters, quartz, and action should be smooth, degree of tightening to ensure airtight, beware of filters, quartz plate rupture. Filters, quartz plate location do not install anti-, quartz reaction indoor wall that protects the filter. 7 . Fixed to the Chamber after Chamber, anechoic chamber attached to the detector, and connect all cables and gas pipelines to avoid leaks, leakage phenomenon. 8 . Cover the cover. 13 Instrument maintenance 1 . Long-term use of the system, pneumatic joints leakage may occur, users response to the gas as a whole do not regularly checked. 2 . Users should always check after cracking tube outlet port and with and without the carbon in the gas circuit. If cracking tubes of carbon deposition in, you can access oxygen combustion in high temperature conditions clear. If carbon deposits in the pipeline. The timely replacement of new line. 3 . Users should be required to replace the oxygen desiccant, to ensure that the system is functioning properly. Note:1. Air drier stuffing (5A molecular sieve ) Processing method : 500 Temperatures, activation of 4 Hours. 4 . Check the use of cracked pipes on a regular basis, if the cracked pipe wall becomes white and rough, instructions for quartz tube lifetime had to, it should be replaced immediately. Analysis of low concentration samples usually, demanding to the Lysis tube, cracked pipe inner wall roughness can lead to drop in its signal strength decreases, lower sensitivity, resolution, Lysis tube on low concentration sample analysis does not apply may also apply to the analysis of high content of samples. 5 . Periodic cleaning Chamber, cleaning methods, see the fifth chapter. 6 . Injector regularly driven screw Guide bar and add lubricant to reduce wear and noise.
本文档为【SY-2000N发光定氮说明书(英文版)】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_633423
暂无简介~
格式:doc
大小:59KB
软件:Word
页数:0
分类:生产制造
上传时间:2019-09-20
浏览量:17