Get the whole picture
TM
FirstMap™ Specifications
www.imperiuminc.com
5901-F Ammendale Road, Beltsville, MD
301/431-2900
sales@imperiuminc.com
Page 1
General
Dimensions
(W x H x D)
Camera: 7.8” x 3.5” x 3.0” (19.8 cm x 8.8 cm x 7.6 cm)
Controller: 12.5” x 8.0” x 3.5” (31.7 cm x 20.3 cm x 8.8 cm)
Weight
Camera: 1.3 lbs. (0.6 kg)
Controller: 6.0 pounds (3.2 kg)
Camera Cable 8.0’ (2.4 m) length
Focus Range
Steel:0” to 2.0” (0 to 5.0 cm)
Composites:0” to 2.0” (0 to 5.0 cm)
Aluminum: 0” to 3.0” (0 to 7.5 cm)
Data Storage 500 megabytes RAM; 80 gigabyte hard drive
Battery Rechargeable14.4 volt lithium-ion;90 minute battery life; built-in charger
Power Requirements 110/240 VAC; 50/60Hz
System Hardware &Software Intel Celeron 1.6 gigahertz processor; Microsoft Windows XP
Test Modes
C-scan: pulse-echo, through transmission
A-scan: pulse-echo, through transmission, dual element
FirstMap™ Specifications
www.imperiuminc.com
5901-F Ammendale Road, Beltsville, MD
301/431-2900
sales@imperiuminc.com
Page 2
Inputs/Outputs
Display
high brightnessTFT color LCD; SVGA; 800W x 600H;
6.75” W x 5.25” H; 8.4” diagonal (17 cm x 13 cm; 21.6 cm)
Sunlight readable
Display Modes C-scan, A-scan, combined C/Ascans Normal & full screen
Software AcoustoVision™ Touchscreen GUI
Ethernet 100 BaseT (1) RJ45, F jack
Wireless 802.11 a/b/g (supports remote NDI system) (1) 4.25” antenna
VGA Controller VGA 800W x 600H (1) 15-pin HD D-sub, F
USB USB 2.0 (2) USB jacks
C-scan
Acoustic Lenses Threeelement F/1 lens set
Acoustic Field of View 1.0” x 1.0” (2.5 cm x 2.5 cm) instantaneous
Imaging ASIC Array Patented Digital Acoustic Video™ Version 6.0
Array Elements 120 x 120 (14,400 pixels)
Pixel Size 100 microns
C-scan Video Rate 30 frames per second
X/Y Spatial Resolution 600 microns (0.6 mm) @ 5 MHz
Dynamic Range 60 dBinstantaneous
Depth Resolution 10 ns
Image Acquisition Range Variable delay from0 µs to 250 µs
Image Acquisition Length Variable detection window from 0 ns to end of range in 10 ns increments
Match Gates C-scan gate start/width can match to A-scan gate start/width
X,Y Defect Sizing User calibrated grid orpoint-to-point manual sizing
Image Capture C-scan, A-scan, combined C/A scans
Image Capture Type JPEG;on-board storage up to 1 million image capture files
Video Capture Type MPEG-3; 60 s max. recordtime/file;on-board storage up to 100,000 files
FirstMap™ Specifications
www.imperiuminc.com
5901-F Ammendale Road, Beltsville, MD
301/431-2900
sales@imperiuminc.com
Page 3
A-scan
Gain 0 to 83dB
Maximum Input Signal 5 Vp-p
Receiver Input Impedance 10 MΩ ± 5%
Receiver Bandwidth 0.2 to 120 MHz @ -3 dB
A-scan Rectification Full, half, none
Receiver Delay 0 to 0.2 µs
Digital Filter Settings Yes
Reject Variable from 0% to 100% FSH
Time Corrected Gain Up to 5 reflected peaks can be used for calibrating TCG
Amplitude Measurement 0% to 110% full screen height with 0.125% resolution
Measurement Rate 250 Hz (equivalent to PRF)
A-scan Gate Start Variable over entire displayed range
A-scan Gate Width Variable from gate start to end of displayed range
A-scan Gate Height Variable from 1% to 100% FSH
Reference Cursors 2 reference cursors
Alarms Alarmfeature for 2nd reference cursor
Acoustic Velocities Pre-installed, editable library of 40commonly inspected materials
Pulser
Pulses per Burst Up to 20 square wave pulses
Pulser Voltage 0 V to 1500 V
Pulse Repetition Frequency 250 Hz
Pulser Rise Time < 15 ns
Bandwidth Adjustable from 0.5 MHz to 7.5 MHz
External Transducer Dual-element, adjustable frequency
FirstMap™ Specifications
www.imperiuminc.com
5901-F Ammendale Road, Beltsville, MD
301/431-2900
sales@imperiuminc.com
Page 4
2-Dimensional Scanning & Stitching
Encoders Two 1.0” (2.5 cm) diameter wheels; 20 steps/mm resolution
Scanning/Stitching Software AcoustoVision™ add-on module
Scanned Imaging Features real-time scan display; automatic image correction; scans stored as JPEGs
Scan Area 12.0” x 12.0” (50 cm x 50 cm) per image
Attachments User removable encoders and external transducer
Certifications and Environmental Qualifications
ASTM E317-06a
Standard Practice for Evaluating Performance Characteristics of Ultrasonic
Pulse-Echo Testing Instruments and Systems
ASTM 1324-11
Standard Guide for Measuring Some Electronic Characteristics of Ultrasonic
Testing Instruments
Operating Temperature 0° C to 50° C (32° F to 122° F); camera head contact to 400 °F (205 °C)
General
Inputs/Outputs
C-scan
A-scan
Pulser
2-Dimensional Scanning & Stitching
Certifications and Environmental Qualifications
本文档为【FirstMap-SPEC-SHEET-2012L】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑,
图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。