The product family ST with the new spring cage system
"mini spring" is extremely space-saving. Space is
saved thanks to a clearly smaller spring system without
having to give up such familiar quality features as the
large insertion space.
The outstanding feature of the feed-through terminals is
their space-saving design, the generous labeling
options and a flexible bridging system.
The insertion space of the ST terminal blocks is
designed in such a way that flexible conductors with the
rated cross section with ferrule can also be wired up
without difficulty.
The ground terminal blocks with the same shape as the
feed-through terminal blocks make contact via simple
snapping on the mounting rail and thus take over the
ground conductor function.
The housings are made of unbreakable polyamide 6.6
of the inflammability class V0 acc. to UL 94.
Marking
A clear assignment of the
connection lines is a pre-
requisite for unambiguous
and correct installation of
terminal strips.
The ST series is ideally
suited to these requirements.
The generous labeling option
using ZB standard Zack
("quick") strip in the terminal
center is always easily accessible and readily
recognizable, even when wired.
Moreover, each termination point can also be labeled
for special applications.
Plug-in bridging system FBS
The ST terminal block has
dual channels for handling
all types of bridging
possibilities. By means of
plug-in bridges the chain
bridging can be achieved
either with a 2-pos. standard
jumper or with multi-position
bridges. The multi-position
version is especially useful
for fast bridging of multi-position terminal strips. The
bridging between non-adjacent terminals can also be
handled with this version. The plug-in bridges are
Spring Cage Feed-Through Terminal Blocks ST
Phoenix Contact GmbH & Co. KG • 32823 Blomberg, Germany
Phone +49 52 35 3-00 • Fax +49 52 35 3-4 12 00 • www.phoenixcontact.com
available in the number of position 2, 3, 4, 5 and 10.
20-pos. bridges can also be delivered for the 4, 5 and
6 mm terminal block pitches which can be cut to suit
your requirements.
There is also the possibility of a practical test
connection in the bridge shaft of the terminal block.
Generous wire entrance
The ST series has large
conductor openings, which
eliminate the need to move
up to a large terminal block
when ferrules are required.
Technical data
Type Order No. Pcs.
Pkt.
Spring cage terminal block,
for mounting on 3 gray terminal width 4.2
blue terminal width 4.2
orange terminal width 4.2
red terminal width 4.2
black terminal width 4.2
ST 1,5 30 31 07 6 50
ST 1,5 BU 30 31 08 9 50
ST 1,5 OG 30 37 01 2 50
ST 1,5 RD 30 37 03 8 50
ST 1,5 BK 30 37 06 7 50
(1) End cover gray D-ST 2,5 30 30 41 7 50
(2) Insulating stop sleeve, prevents unintentional clamping
of the insulation in the case of smaller cross sections
Cross section range: 0.08-0.2 mm2 white
0.25-0.5 mm2 gray
ISH 1,5/0,2 32 06 13 1 50
ISH 1,5/0,5 30 31 03 4 50
(3) Plug-in bridge, for 2-pos.
cross-connections in the 3-pos.
terminal center 4-pos.
5-pos.
10-pos.
20-pos.
FBS 2-4 Imax.: 17.5 A 30 30 11 6 50
FBS 3-4 17.5 A 30 30 12 9 50
FBS 4-4 17.5 A 30 30 13 2 50
FBS 5-4 17.5 A 30 30 14 5 50
FBS 10-4 17.5 A 30 30 15 8 10
FBS 20-4 17.5 A 30 30 35 2 10
(4) Partition plate, for
visual and electrical separation
of terminal groups, 2 mm thick
ATP-ST 4 30 30 72 1 50
(5) Test adapter, for 4 mm ∅ test connector PS
and 4 mm ∅ safety test connectors,
making contact in the bridge shaft
PAI 4 30 30 92 5 10
(6) Modular test connector, for individual
assembly of test connector strips,
can be labeled with ZBF 4
PS-4 30 30 97 0 10
(7) Warning cover, for the
operating shafts of the “mini-spring”
ST spring cage terminal blocks
WST 1,5 30 30 95 8 10
(8) Screwdriver, for
actuating the tension spring SZF 0 - 0,4 x 2,5 12 04 50 4 10
(9) Zack strip, flat,
for labeling the outer marker grooves white ZBF 4:UNPRINTED 08 08 58 7 10
(10) Zack strip, 10-section, for
labeling in the terminal center white ZB 4:UNPRINTED 08 05 00 1 10
Dimensions
Width / length / end cover width [mm] 4.2 / 48.5 / 2.2
Height (NS 35/7.5 / NS 35/15) [mm] 36.5 / 44
Technical data in accordance with IEC/ DIN VDE
Maximum load current / cross section [A] / [mm2] 17.5 / 1.5
Rated surge voltage / contamination class [kV] / – 6 / 3
Surge voltage category / insulation material group – / – III / I
Connection capacity
Stranded with ferrule with plastic sleeve [mm2] 0.25 - 1.5
Stranded with ferrule without plastic sleeve [mm2] 0.25 - 1.5
Stranded with TWIN ferrule with plastic sleeve [mm2] 0.5
Stripping length [mm] 10
Internal cylindrical gauge (IEC 60 947-1) A 1
Insulating material PA
Inflammability class in acc. with UL 94 V0
Approval data (UL and CSA/CUL)
Nom. voltage / nom. current / conduc. sizes UL: [V] / [A] / AWG –
CSA/CUL: [V] / [A] / AWG –
Feed-Through Terminal Block
ST 1,5
Phoenix Contact page 2 of 15
(IEC) rigid flexible I U
[mm2] solid stranded AWG [A] [V]
IEC 60 947-7-1 0.08-1.5 0.08-1.5 28-16 17.5 500
EN 50 019* 0.08-1.5 0.08-1.5 28-16 17.5 420
* EC Prototype certificate no.: KEMA 01ATEX2129U
For information on installation and usage of accessories for EEx e applications,
see www.clipline.phoenixcontact.com.
u P F KEMA
Technical data
Type Order No. Pcs.
Pkt.
Spring cage terminal block,
for mounting on 3 green-yellow terminal width 4.2 ST 1,5-PE 30 31 51 3 50
(1) End cover gray D-ST 2,5 30 30 41 7 50
(2) Insulating stop sleeve, prevents unintentional clamping
of the insulation in the case of smaller cross sections
Cross section range: 0.08-0.2 mm2 white
0.25-0.5 mm2 gray
ISH 1,5/0,2 32 06 13 1 50
ISH 1,5/0,5 30 31 03 4 50
(3) Screwdriver, for
actuating the tension spring SZF 0 - 0,4 x 2,5 12 04 50 4 10
(4) Zack strip, flat,
for labeling the outer marker grooves white ZBF 4:UNPRINTED 08 08 58 7 10
(5) Zack strip, 10-section, for
labeling in the terminal center white ZB 4:UNPRINTED 08 05 00 1 10
Dimensions
Width / length / end cover width [mm] 4.2 / 48.5 / 2.2
Height (NS 35/7.5 / NS 35/15) [mm] 36.5 / 44
Technical data in accordance with IEC/ DIN VDE
Maximum load current / cross section [A] / [mm2] –
Rated surge voltage / contamination class [kV] / – 6 / 3
Surge voltage category / insulation material group – / – III / I
Connection capacity
Stranded with ferrule with plastic sleeve [mm2] 0.25 - 1.5
Stranded with ferrule without plastic sleeve [mm2] 0.25 - 1.5
Stranded with TWIN ferrule with plastic sleeve [mm2] 0.5
Stripping length [mm] 10
Internal cylindrical gauge (IEC 60 947-1) A 1
Insulating material PA
Inflammability class in acc. with UL 94 V0
Approval data (UL and CSA/CUL)
Nom. voltage / nom. current / conduc. sizes UL: [V] / [A] / AWG –
CSA/CUL: [V] / [A] / AWG –
Ground Terminal Block
ST 1,5-PE
Phoenix Contact page 3 of 15
(IEC) rigid flexible
[mm2] solid stranded AWG
IEC 60 947-7-2 0.08-1.5 0.08-1.5 28-16
EN 50 019* 0.08-1.5 0.08-1.5 28-16
* EC Prototype certificate no.: KEMA 01ATEX2129U
For information on installation and usage of accessories for EEx e applications,
see www.clipline.phoenixcontact.com.
Observe the current carrying capacity of mounting rails.
u P F KEMA
Technical data
Type Order No. Pcs.
Pkt.
Spring cage terminal block,
for mounting on 3 gray terminal width 5.2
blue terminal width 5.2
orange terminal width 5.2
red terminal width 5.2
black terminal width 5.2
ST 2,5 30 31 21 2 50
ST 2,5 BU 30 31 22 5 50
ST 2,5 OG 30 37 07 0 50
ST 2,5 RD 30 37 09 6 50
ST 2,5 BK 30 37 12 2 50
(1) End cover gray D-ST 2,5 30 30 41 7 50
(2) Insulating stop sleeve, prevents unintentional clamping
of the insulation in the case of smaller cross sections
Cross section range: 0.08-0.2 mm2 white
0.25-0.5 mm2 gray
0.75-1 mm2 black
ISH 2,5/0,2 30 02 84 3 50
ISH 2,5/0,5 30 02 85 6 50
ISH 2,5/1 30 02 86 9 50
(3) Plug-in bridge, for 2-pos.
cross-connections in the 3-pos.
terminal center 4-pos.
5-pos.
10-pos.
20-pos.
FBS 2-5 Imax.: 24 A 30 30 16 1 50
FBS 3-5 24 A 30 30 17 4 50
FBS 4-5 24 A 30 30 18 7 50
FBS 5-5 24 A 30 30 19 0 50
FBS 10-5 24 A 30 30 21 3 10
FBS 20-5 24 A 30 30 22 6 10
(4) Partition plate, for
visual and electrical separation
of terminal groups, 2 mm thick
ATP-ST 4 30 30 72 1 50
(5) Test adapter, for 4 mm ∅ test connector PS
and 4 mm ∅ safety test connectors,
making contact in the bridge shaft
PAI 4 30 30 92 5 10
(6) 2.3 mm ∅ test connector1), consisting of
metal part and red insulating sleeve
(7) Modular test connector, can be labeled with ZBF 5
MPS-RD 02 01 55 3 10
PS 5 30 30 98 3 10
(8) Warning cover, for the
operating shafts of the “mini-spring”
ST spring cage terminal blocks
WST 2,5 30 30 94 1 10
(9) Screwdriver, for
actuating the tension spring SZF 1 - 0,6 x 3,5 12 04 51 7 10
(10) Zack strip, flat,
for labeling the outer marker grooves white ZBF 5 :UNPRINTED 08 08 64 2 10
(11) Zack strip, 10-section, for
labeling in the terminal center white ZB 5:UNPRINTED 10 50 00 4 10
Dimensions
Width / length / end cover width [mm] 5.2 / 48.5 / 2.2
Height (NS 35/7.5 / NS 35/15) [mm] 36.5 / 44
Technical data in accordance with IEC/ DIN VDE
Maximum load current / cross section [A] / [mm2] 31 / 4
Rated surge voltage / contamination class [kV] / – 8 / 3
Surge voltage category / insulation material group – / – III / I
Connection capacity
Stranded with ferrule with plastic sleeve [mm2] 0.25 - 2.5
Stranded with ferrule without plastic sleeve [mm2] 0.25 - 2.5
Stranded with TWIN ferrule with plastic sleeve [mm2] 0.5
Stripping length [mm] 10
Internal cylindrical gauge (IEC 60 947-1) A 3
Insulating material PA
Inflammability class in acc. with UL 94 V0
Approval data (UL and CSA/CUL)
Nom. voltage / nom. current / conduc. sizes UL: [V] / [A] / AWG 600 / 20 / 26 - 12
CSA/CUL: [V] / [A] / AWG 600 / 20 / 26 - 12
Feed-Through Terminal Block
ST 2,5
Phoenix Contact page 4 of 15
(IEC) rigid flexible I U
[mm2] solid stranded AWG [A] [V]
IEC 60 947-7-1 0.08-4 0.08-2.5 28-12 31 800
EN 50 019* 0.08-4 0.08-2.5 28-12 25/21 550
* EC Prototype certificate no.: KEMA 00ATEX2052U
For information on installation and usage of accessories for EEx e applications,
see www.clipline.phoenixcontact.com.
u P F KEMA
1) Further colors on request.
Technical data
Type Order No. Pcs.
Pkt.
Spring cage terminal block,
for mounting on 3 green-yellow terminal width 5.2 ST 2,5-PE 30 31 23 8 50
(1) End cover gray D-ST 2,5 30 30 41 7 50
(2) Insulating stop sleeve, prevents unintentional clamping
of the insulation in the case of smaller cross sections
Cross section range: 0.08-0.2 mm2 white
0.25-0.5 mm2 gray
0.75-1 mm2 black
ISH 2,5/0,2 30 02 84 3 50
ISH 2,5/0,5 30 02 85 6 50
ISH 2,5/1 30 02 86 9 50
(3) Screwdriver, for
actuating the tension spring SZF 1 - 0,6 x 3,5 12 04 51 7 10
(4) Zack strip, flat,
for labeling the outer marker grooves white ZBF 5 :UNPRINTED 08 08 64 2 10
(5) Zack strip, 10-section, for
labeling in the terminal center white ZB 5:UNPRINTED 10 50 00 4 10
Dimensions
Width / length / end cover width [mm] 5.2 / 48.5 / 2.2
Height (NS 35/7.5 / NS 35/15) [mm] 36.5 / 44
Technical data in accordance with IEC/ DIN VDE
Maximum load current / cross section [A] / [mm2] –
Rated surge voltage / contamination class [kV] / – 8 / 3
Surge voltage category / insulation material group – / – III / I
Connection capacity
Stranded with ferrule with plastic sleeve [mm2] 0.25 - 2.5
Stranded with ferrule without plastic sleeve [mm2] 0.25 - 2.5
Stranded with TWIN ferrule with plastic sleeve [mm2] 0.5
Stripping length [mm] 10
Internal cylindrical gauge (IEC 60 947-1) A 3
Insulating material PA
Inflammability class in acc. with UL 94 V0
Approval data (UL and CSA/CUL)
Nom. voltage / nom. current / conduc. sizes UL: [V] / [A] / AWG – / – / 26 - 12
CSA/CUL: [V] / [A] / AWG – / – / 26 - 12
Ground Terminal Block
ST 2,5-PE
Phoenix Contact page 5 of 15
(IEC) rigid flexible
[mm2] solid stranded AWG
IEC 60 947-7-2 0.08-4 0.08-2.5 28-12
EN 50 019* 0.08-4 0.08-2.5 28-12
* EC Prototype certificate no.: KEMA 00ATEX2052U
For information on installation and usage of accessories for EEx e applications,
see www.clipline.phoenixcontact.com.
Observe the current carrying capacity of mounting rails.
u P F KEMA
Technical data
Type Order No. Pcs.
Pkt.
Spring cage terminal block,
for mounting on 3 gray terminal width 6.2
blue terminal width 6.2
orange terminal width 6.2
red terminal width 6.2
black terminal width 6.2
ST 4 30 31 36 4 50
ST 4 BU 30 31 37 7 50
ST 4 OG 30 37 13 5 50
ST 4 RD 30 37 15 1 50
ST 4 BK 30 37 18 0 50
(1) End cover gray D-ST 4 30 30 42 0 50
(2) Insulating stop sleeve, prevents unintentional clamping
of the insulation in the case of smaller cross sections
Cross section range: 0.25-0.5 mm2 gray
0.75-1 mm2 black
ISH 4/0,5 30 02 88 5 50
ISH 4/1 30 02 89 8 50
(3) Plug-in bridge, for 2-pos.
cross-connections in the 3-pos.
terminal center 4-pos.
5-pos.
10-pos.
20-pos.
FBS 2-6 Imax.: 32 A 30 30 33 6 50
FBS 3-6 32 A 30 30 24 2 50
FBS 4-6 32 A 30 30 25 5 50
FBS 5-6 32 A 30 30 34 9 50
FBS 10-6 32 A 30 30 27 1 10
FBS 20-6 32 A 30 30 36 5 10
(4) Partition plate, for
visual and electrical separation
of terminal groups, 2 mm thick
ATP-ST 4 30 30 72 1 50
(5) Test adapter, for 4 mm ∅ test connector PS
and 4 mm ∅ safety test connectors,
making contact in the bridge shaft
PAI 4 30 30 92 5 10
(6) 2.3 mm ∅ test connector1), consisting of
metal part and red insulating sleeve
(7) Modular test connector, can be labeled with ZBF 6
MPS-RD 02 01 55 3 10
PS-6 30 30 99 6 10
(8) Warning cover, for the
operating shafts of the “mini-spring”
ST spring cage terminal blocks
WST 4 30 30 95 4 10
(9) Screwdriver, for
actuating the tension spring SZF 1 - 0,6 x 3,5 12 04 51 7 10
(10) Zack strip, flat,
for labeling the outer marker grooves white ZBF 6:UNPRINTED 08 08 71 0 10
(11) Zack strip, 10-section, for
labeling in the terminal center white ZB 6:UNPRINTED 10 51 00 3 10
Dimensions
Width / length / end cover width [mm] 6.2 / 56 / 2.2
Height (NS 35/7.5 / NS 35/15) [mm] 36.5 / 44
Technical data in accordance with IEC/ DIN VDE
Maximum load current / cross section [A] / [mm2] 40 / 6
Rated surge voltage / contamination class [kV] / – 8 / 3
Surge voltage category / insulation material group – / – III / I
Connection capacity
Stranded with ferrule with plastic sleeve [mm2] 0.25 - 4
Stranded with ferrule without plastic sleeve [mm2] 0.25 - 4
Stranded with TWIN ferrule with plastic sleeve [mm2] 0.5 - 1
Stripping length [mm] 10
Internal cylindrical gauge (IEC 60 947-1) A 4
Insulating material PA
Inflammability class in acc. with UL 94 V0
Approval data (UL and CSA/CUL)
Nom. voltage / nom. current / conduc. sizes UL: [V] / [A] / AWG 600 / 30 / 20 - 10
CSA/CUL: [V] / [A] / AWG 600 / 30 / 20 - 10
Feed-Through Terminal Block
ST 4
Phoenix Contact page 6 of 15
(IEC) rigid flexible I U
[mm2] solid stranded AWG [A] [V]
IEC 60 947-7-1 0.08-6 0.08-4 28-10 40 800
EN 50 019* 0.08-6 0.08-4 28-10 34/30 550
* EC Prototype certificate no.: KEMA 00ATEX2129U
For information on installation and usage of accessories for EEx e applications,
see www.clipline.phoenixcontact.com.
u P F KEMA
1) Further colors on request.
Technical data
Type Order No. Pcs.
Pkt.
Spring cage terminal block,
for mounting on 3 green-yellow terminal width 6.2 ST 4-PE 30 31 38 0 50
(1) End cover gray D-ST 4 30 30 42 0 50
(2) Insulating stop sleeve, prevents unintentional clamping
of the insulation in the case of smaller cross sections
Cross section range: 0.25-0.5 mm2 gray
0.75-1 mm2 black
ISH 4/0,5 30 02 88 5 50
ISH 4/1 30 02 89 8 50
(3) Screwdriver, for
actuating the tension spring SZF 1 - 0,6 x 3,5 12 04 51 7 10
(4) Zack strip, flat,
for labeling the outer marker grooves white ZBF 6:UNPRINTED 08 08 71 0 10
(5) Zack strip, 10-section, for
labeling in the terminal center white ZB 6:UNPRINTED 10 51 00 3 10
Dimensions
Width / length / end cover width [mm] 6.2 / 56 / 2.2
Height (NS 35/7.5 / NS 35/15) [mm] 36.5 / 44
Technical data in accordance with IEC/ DIN VDE
Maximum load current / cross section [A] / [mm2] –
Rated surge voltage / contamination class [kV] / – 8 / 3
Surge voltage category / insulation material group – / – III / I
Connection capacity
Stranded with ferrule with plastic sleeve [mm2] 0.25 - 4
Stranded with ferrule without plastic sleeve [mm2] 0.25 - 4
Stranded with TWIN ferrule with plastic sleeve [mm2] 0.5 - 1
Stripping length [mm] 10
Internal cylindrical gauge (IEC 60 947-1) A 4
Insulating material PA
Inflammability class in acc. with UL 94 V0
Approval data (UL and CSA/CUL)
Nom. voltage / nom. current / conduc. sizes UL: [V] / [A] / AWG – / – / 20 - 10
CSA/CUL: [V] / [A] / AWG – / – / 20 - 10
Ground Terminal Block
ST 4-PE
Phoenix Contact page 7 of 15
(IEC) rigid flexible
[mm2] solid stranded AWG
IEC 60 947-7-2 0.08-6 0.08-4 28-10
EN 50 019* 0.08-6 0.08-4 28-10
* EC Prototype certificate no.: KEMA 00ATEX2129U
For information on installation and usage of accessories for EEx e applications,
see www.clipline.phoenixcontact.com.
Observe the current carrying capacity of mounting rails.
u P F KEMA
Technical data
Type Order No. Pcs.
Pkt.
Spring cage terminal block,
for mounting on 3 gray terminal width 8.2
blue terminal width 8.2
ST 6 30 31 48 7 50
ST 6 BU 30 31 49 0 50
(1) End cover gray D-ST 6 30 30 43 3 50
(2) Plug-in bridge, for 2-pos.
cross-connections in the 3-pos.
terminal center 4-pos.
5-pos.
10-pos.
FBS 2-8 Imax.: 41 A 30 30 28 4 10
FBS 3-8 41 A 30 30 29 7 10
FBS 4-8 41 A 30 30 30 7 10
FBS 5-8 41 A 30 30 31 0 10
FBS 10-8 41 A 30 30 32 3 10
(3) Reducing bridge, for connection of one
ST 6 with ST 2,5 or ST 4 RB ST 6-(2,5/4) Imax.: 48 A 30 30 86 0 10
(4) Partition plate, for
visual and electrical separation
of terminal groups, 2 mm thick
ATP-ST 6 30 24 48 1 50
(5) Test adapter, for 4 mm ∅ test connector PS
and 4 mm ∅ safety test connectors,
making contact in the bridge shaft
PAI 4 30 30 92 5 10
(6) 2.3 mm ∅ test connector1), consisting of
metal part and red insulating sleeve
(7) Modular test connector, can be labeled with ZBF 8
MPS-RD 02 01 55 3 10
PS 8 30 31 00 5 10
(8) Warning cover, for the
operating shafts of the “mini-spring”
ST spring cage terminal blocks
WST 6 30 30 96 7 10
(9) Screwdriver, for
actuating the tension spring SZF 2 - 0,8 x 4,0 12 04 52 0 10
(10) Zack marker sheet, flat,
for labeling the outer marker grooves white ZBF 8:UNPRINTED 08 08 78 1 10
(11) Zack strip, 10-section, for
labeling in the terminal center white ZB 8:UNPRINTED 10 52 00 2 10
Dimensions
Width / length / end cover width [mm] 8.2 / 69.5 / 2.2
Height (NS 35/7.5 / NS 35/15) [mm] 43.5 / 51
Technical data in accordance with IEC/ DIN VDE
Maximum load current / cross section [A] / [mm2] 52 / 10
Rated surge voltage / contamination class [kV] / – 8 / 3
Surge voltage category / insulation material group – / – III / I
Connection capacity
Stranded with ferrule with plastic sleeve [mm2] 0.25 - 6
Stranded with ferrule without plastic sleeve [mm2] 0.25 - 6
Stranded with TWIN ferrule with plastic sleeve [mm2] 0.5 - 1.5
Stripping length [mm] 12
Internal cylindrical gauge (IEC 60 947-1) A 5
Insulating material PA
Inflammability class in acc. with UL 94 V0
Approval data (UL and CSA/CUL)
Nom. voltage / nom. current / conduc. sizes UL: [V] / [A] / AWG 600 / 50 / 20 - 8
CSA/CUL: [V] / [A] / AWG 600 / 50 / 20 - 8
Feed-Through Terminal Block
ST 6
Phoenix Contact page 8 of 15
(IEC) rigid flexible I U
[mm2] solid stranded AWG [A] [V]
IEC 60 947-7-1 0.2-10 0.2-6 24-8 52 800
EN 50 019* 0.2-10 0.2-6 24-8 45/36 550
* EC Prototype certificate no: KEMA 00ATEX2129U
For information on installation and usage of accessories for EEx e applications,
see www.clipline.phoenixcontact.com.
u P F KEMA
1) Further colors on request.
Technical data
Type Order No. Pcs.
Pkt.
Spring cage terminal block,
for mounting on 3 green-yellow terminal width 8.2 ST 6-PE 30 31 50 0 50
(1) End cover gray D-ST 6 30 30 43 3 50
(2)