首页 FSMR_dat-sw_en[1]

FSMR_dat-sw_en[1]

举报
开通vip

FSMR_dat-sw_en[1] Te st & M ea su re m en t Da ta S he et | 09 .0 0R&S®FSMR Measuring Receiver Specifications Version 09.00, July 2011 2 Rohde & Schwarz R&S®FSMR Measuring Receiver CONTENTS Specifications.................................................

FSMR_dat-sw_en[1]
Te st & M ea su re m en t Da ta S he et | 09 .0 0R&S®FSMR Measuring Receiver Specifications Version 09.00, July 2011 2 Rohde & Schwarz R&S®FSMR Measuring Receiver CONTENTS Specifications.................................................................................................................................................................. 3 Frequency ...............................................................................................................................................................................................3 Measuring receiver ......................................................................................................................................................... 3 Frequency counter ..................................................................................................................................................................................3 RF power ................................................................................................................................................................................................4 RF level (tuned receiver).........................................................................................................................................................................5 Modulation ..............................................................................................................................................................................................7 Audio.....................................................................................................................................................................................................10 Spectrum analyzer ........................................................................................................................................................ 12 Frequency .............................................................................................................................................................................................12 Sweep ...................................................................................................................................................................................................13 Resolution bandwidths..........................................................................................................................................................................13 Level .....................................................................................................................................................................................................14 I/Q data .................................................................................................................................................................................................17 Audio demodulation ..............................................................................................................................................................................17 General........................................................................................................................................................................... 18 Trigger functions ...................................................................................................................................................................................18 Inputs and outputs (front panel) ............................................................................................................................................................18 Inputs and outputs (rear panel).............................................................................................................................................................20 General data .........................................................................................................................................................................................21 Options .......................................................................................................................................................................... 22 R&S®FSMR-B2 YIG preselection (for the R&S®FSMR26/43/50), R&S®FSMR-B223 YIG preselection with 20 dB preamplifier (for the R&S®FSMR26 only, requires the R&S®FSU-B25 option).........................................................................................................22 R&S®FSU-B9 tracking generator, R&S®FSU-B12 step attenuator for tracking generator ....................................................................25 R&S®FSMR-B23 RF preamplifier (for the R&S®FSMR26 only, requires the R&S®FSU-B25 option) ...................................................27 R&S®FSU-B24 30 dB RF preamplifier (for the R&S®FSMR26/43/50) ..................................................................................................28 R&S®FSU-B25 electronic attenuator and preamplifier..........................................................................................................................32 Accessories................................................................................................................................................................... 33 R&S®NRP-Z27/-Z37 power sensor modules ........................................................................................................................................33 R&S®FSMR-Z2 attenuation calibration kit.............................................................................................................................................35 Ordering information .................................................................................................................................................... 36 Base unit ...............................................................................................................................................................................................36 Hardware options..................................................................................................................................................................................36 Software options ...................................................................................................................................................................................37 Accessories...........................................................................................................................................................................................37 Recommended extras...........................................................................................................................................................................38 Version 09.00, July 2011 Rohde & Schwarz R&S®FSMR Measuring Receiver 3 Specifications Specifications apply under the following conditions: 30 minutes warm-up time at ambient temperature (60 minutes for RF level), specified environmental conditions met, calibration cycle adhered to, and total calibration performed. Data without tolerance limit is not binding. Data designated 'nominal' applies to design parameters and is not tested. Accuracy does not include mismatch error and errors due to standard deviation of the measurement readings, which are influenced by the number of averages. Frequency R&S®FSMR3: DC-coupled 20 Hz to 3.6 GHz AC-coupled 1 MHz to 3.6 GHz R&S®FSMR26: DC-coupled 20 Hz to 26.5 GHz AC-coupled 10 MHz to 26.5 GHz R&S®FSMR43: DC-coupled 20 Hz to 43 GHz Frequency range R&S®FSMR50: DC-coupled 20 Hz to 50 GHz Internal timebase Reference frequency, internal, nominal standard OCXO Aging per day after 30 days of continuous operation 1 × 10–9 Aging per year after 30 days of continuous operation 1 × 10–7 Temperature drift +5 °C to +45 °C 8 × 10–8 Total error per year 1.8 × 10–7 Reference frequency, internal, nominal R&S®FSU-B4 option Aging per day after 30 days of continuous operation 2 × 10–10 Aging per year after 30 days of continuous operation 3 × 10–8 Temperature drift +5 °C to +45 °C 1 × 10–9 Total error per year 5 × 10–8 External reference frequency 1 MHz to 20 MHz, 1 Hz steps Measuring receiver Frequency counter R&S®FSMR3 20 Hz to 3.6 GHz R&S®FSMR26 20 Hz to 26.5 GHz R&S®FSMR43 20 Hz to 43 GHz Frequency range R&S®FSMR50 20 Hz to 50 GHz Frequency display frequency offset 10 kHz to 26.5 GHz –120 dBm Sensitivity 26.5 GHz to 50 GHz –100 dBm Maximum frequency counter resolution 0.001 Hz Count accuracy S/N > 25 dB ±(frequency × reference accuracy + 0.1 Hz) Version 09.00, July 2011 4 Rohde & Schwarz R&S®FSMR Measuring Receiver RF power The R&S®FSMR performs absolute RF power measurements when the R&S®NRP-Zxx power sensors are connected to the R&S®FSMR. The R&S®NRP-Z27 and R&S®NRP-Z37 power sensor modules include a power splitter. All specifications in this section describe a setup where the RF output of the R&S®NRP-Z27/-Z37 power sensor module is connected to the RF input of the R&S®FSMR. For specifications of the R&S®NRP-Z27/-Z37, see the “Accessories” section and the R&S®NRP2 and R&S®NRP-Zxx data sheet (PD 5213.5539.22). For specifications of the other R&S®NRP-Zxx power sensors, see the R&S®NRP2 and R&S®NRP-Zxx data sheet (PD 5213.5539.22). power sensor type and connector thermoelectric power sensors frequency range level range R&S®NRP-Z27 N male with int. splitter DC to 18 GHz –24 dBm to +26 dBm R&S®NRP-Z37 3.5 mm male with int. splitter DC to 26.5 GHz –24 dBm to +26 dBm R&S®NRP-Z51 N male DC to 18 GHz –30 dBm to +20 dBm R&S®NRP-Z55 2.92 mm male DC to 40 GHz –30 dBm to +20 dBm diode power sensors R&S®NRP-Z11 N male 10 MHz to 8 GHz –67 dBm to +23 dBm R&S®NRP-Z21 N male 10 MHz to 18 GHz –67 dBm to +23 dBm R&S®NRP-Z22 N male, int. attenuator 10 MHz to 18 GHz –57 dBm to +33 dBm R&S®NRP-Z23 N male, int. attenuator 10 MHz to 18 GHz –47 dBm to +42 dBm R&S®NRP-Z24 N male, int. attenuator 10 MHz to 18 GHz –42 dBm to +45 dBm R&S®NRP-Z81 N male 50 MHz to 18 GHz –60 dBm to +20 dBm RF frequency range, level range R&S®NRP-Z91 N male 9 kHz to 6 GHz –67 dBm to +23 dBm R&S®FSMR with R&S®NRP-Z27/-Z37 power sensor module, input level: –10 dBm to +26 dBm temperature range: +15 °C to +35 °C temperature range: 0 °C to +50 °C DC to 4.2 GHz 0.083 dB 0.107 dB > 4.2 GHz to 8 GHz 0.099 dB 0.123 dB > 8 GHz to 12.4 GHz 0.107 dB 0.135 dB > 12.4 GHz to 18 GHz 0.130 dB 0.159 dB > 18 GHz to 26.5 GHz 0.167 dB 0.212 dB without numeric isolation correction (VSWR correction OFF) temperature range: +15 °C to +35 °C temperature range: 0 °C to +50 °C DC to 4.2 GHz 0.120 dB 0.138 dB > 4.2 GHz to 8 GHz 0.166 dB 0.181 dB > 12.4 GHz to 18 GHz 0.187 dB 0.207 dB RF power accuracy > 18 GHz to 26.5 GHz 0.235 dB 0.269 dB RF power resolution 0.001 dB Instrumentation accuracy not applicable RF range-to-range error not applicable 0.5 W (+27 dBm) continuous average 1.0 W (+30 dBm) for max. 10 minutes Max. power pulse energy 30 µWs RF signal output of the R&S®NRP-Z27/-Z37 connected to the R&S®FSMR RF input R&S®NRP-Z27 R&S®NRP-Z37 DC to 2 GHz < 1.15 < 1.15 > 2 GHz to 4.2 GHz < 1.18 < 1.18 > 4.2 GHz to 8 GHz < 1.23 < 1.23 > 8 GHz to 12.4 GHz < 1.25 < 1.25 > 12.4 GHz to 18 GHz < 1.38 < 1.30 Input VSWR > 18 GHz to 26.5 GHz < 1.45 Zero offset expanded uncertainty (k = 2) after zeroing < 400 nW (typ. 160 nW) Zero drift of meter not applicable Display noise two standard deviations, 10.24 s integration time < 240 nW (typ. 120 nW) Zero drift of sensor within 1 hour after zeroing, permissible temperature change ±1 °C, following two-hour warm-up of power sensor < 160 nW Power range of the R&S®FSMR with the R&S®NRP-Z27/-Z37 power sensor module –24 dBm (4 µW) to +26 dBm (400 mW); –24 dBm to +30 dBm (1 W) for max. 10 minutes, one range without subranges Response time 100 ms × number of averages (nom.) absolute mode dBm, W Display units relative mode dB, % Version 09.00, July 2011 Rohde & Schwarz R&S®FSMR Measuring Receiver 5 RF level (tuned receiver) R&S®FSMR3 100 kHz to 3.6 GHz R&S®FSMR26 100 kHz to 26.5 GHz R&S®FSMR43 100 kHz to 43 GHz Frequency range R&S®FSMR50 100 kHz to 50 GHz Display resolution 0.001 dB in absolute and relative mode absolute mode dBm Display units relative mode dB R&S®NRP-Z27/-Z37 connected see “RF power” section Input VSWR base instrument without power sensor module see “Inputs and outputs” section Measurement time 500 ms (nom.) for single measurement Relative level measurement R&S®FSMR3 100 kHz to 3.6 GHz R&S®FSMR26 100 kHz to 26.5 GHz R&S®FSMR43 100 kHz to 43 GHz Frequency range R&S®FSMR50 100 kHz to 50 GHz RF, R&S®FSMR RF input 100 kHz to 10 MHz +30 dBm to –120 dBm 10 MHz to 3.6 GHz without preamplifier +30 dBm to –130 dBm with preamplifier (R&S®FSU-B25 option) +30 dBm to –140 dBm 3.6 GHz to 26.5 GHz +30 dBm to –130 dBm Level range 26.5 GHz to 50 GHz +30 dBm to –120 dBm Linearity input level: +20 dBm to –140 dBm ±0.01 dB ± 0.005 dB per 10 dB step applies to RF range changes; the R&S®FSMR performs RF range changes at input levels of approx. –40 dBm and 0 dBm RF: 100 kHz to 22 GHz 0.005 dB 22 GHz to 40 GHz 0.015 dB Range-to-range error 40 GHz to 50 GHz 0.045 dB Version 09.00, July 2011 6 Rohde & Schwarz R&S®FSMR Measuring Receiver Absolute level measurement The R&S®FSMR performs absolute RF level measurements when the R&S®NRP-Zxx power sensors are connected to the R&S®FSMR. The R&S®NRP-Z27 and R&S®NRP-Z37 power sensor modules include a power splitter. All specifications in this section describe a setup where the RF output of the R&S®NRP-Z27/-Z37 power sensor module is connected to the RF input of the R&S®FSMR. For specifications of the R&S®NRP-Z27/-Z37, see the “Accessories” section and the R&S®NRP2 and R&S®NRP-Zxx data sheet (PD 5213.5539.22). RF, R&S®NRP-Z27/-Z37 RF input 100 kHz to 10 MHz +30 dBm to –110 dBm 10 MHz to 3.6 GHz without preamplifier +30 dBm to –120 dBm with preamplifier (R&S®FSU-B25 option) +30 dBm to –130 dBm 3.6 GHz to 26.5 GHz +30 dBm to –120 dBm Level range 26.5 GHz to 50 GHz +30 dBm to –110 dBm R&S®FSMR with R&S®NRP-Z27/-Z37 power sensor module, temperature range: +15 °C to +35 °C RF: 100 kHz to 4.2 GHz –130 dBm to +26 dBm ±0.083 dB ± 0.005 dB per 10 dB step +26 dBm to +30 dBm ±0.102 dB ± 0.005 dB per 10 dB step RF: 4.2 GHz to 8 GHz –120 dBm to +26 dBm ±0.099 dB ± 0.005 dB per 10 dB step +26 dBm to +30 dBm ±0.144 dB ± 0.005 dB per 10 dB step RF: 8 GHz to 12.4 GHz –120 dBm to +26 dBm ±0.107 dB ± 0.005 dB per 10 dB step +26 dBm to +30 dBm ±0.144 dB ± 0.005 dB per 10 dB step RF: 12.4 GHz to 18 GHz –120 dBm to +26 dBm ±0.130 dB ± 0.005 dB per 10 dB step +26 dBm to +30 dBm ±0.144 dB ± 0.005 dB per 10 dB step RF: 18 GHz to 26.5 GHz –120 dBm to +26 dBm ±0.167 dB ± 0.005 dB per 10 dB step Accuracy +26 dBm to +30 dBm ±0.178 dB ± 0.005 dB per 10 dB step applies to RF range changes; the R&S®FSMR performs RF range changes at input levels of approx. –40 dBm and 0 dBm RF: 100 kHz to 22 GHz 0.005 dB 22 GHz to 40 GHz 0.015 dB Range-to-range error 40 GHz to 50 GHz 0.045 dB Version 09.00, July 2011 Rohde & Schwarz R&S®FSMR Measuring Receiver 7 Modulation Amplitude modulation (AM) Input level range RF: 100 kHz to 50 GHz –40 dBm to +30 dBm Modulation depth range RF: 100 kHz to 50 GHz 0 % to 100 % Modulation depth uncertainty depth of modulation: 5 % to 99 % (residual AM not included) RF modulation rate 100 kHz to 10 MHz 10 Hz to 10 kHz 1 < 1.5 % of reading ≥ 10 MHz 10 Hz to 50 kHz 2 < 1 % of reading 50 kHz to 100 kHz < 1.5 % of reading Absolute 90 Hz to 150 Hz < 0.4 % of reading RF modulation rate 100 kHz to 10 MHz 10 Hz to 10 kHz 1 < 0.3 % of reading ≥ 10 MHz 10 Hz to 50 kHz 2 < 0.3 % of reading Flatness, referenced to 1 kHz 50 kHz to 100 kHz < 0.8 % of reading modulation rate: 400 Hz/1 kHz, measurement bandwidth: 3 kHz RF FM deviation 100 kHz to 10 MHz 5 kHz < 0.2 % (nom.) FM rejection ≥ 10 MHz 50 kHz < 0.2 % (nom.) Residual AM measurement bandwidth: 3 kHz detector: RMS RF ≥ 100 kHz mixer level ≥ –15 dBm < 0.01 % Harmonic distortion measurement bandwidth: 250 kHz or 10th harmonic, whichever is lower; depth of modulation: 5 % to 99 % RF modulation rate Total harmonic distortion of demodulated signal 100 kHz to 10 MHz 50 Hz to 10 kHz < 0.3 % (–50.5 dB) ≥ 10 MHz 50 Hz to 100 kHz < 0.3 % (–50.5 dB) Distortion measurement see “Audio: Distortion and noise” section Detectors +Peak, –Peak, ±Peak/2, RMS, AVG (RMS sine wave calibrated) 1 Modulation rates ≥ 50 Hz with default settings, ≥ 10 Hz with meas. time ≥ 400 ms. 2 Modulation rates ≥ 50 Hz with default settings, ≥ 10 Hz with meas. time = 400 ms and demodulation bandwidth = 800 kHz. Version 09.00, July 2011 8 Rohde & Schwarz R&S®FSMR Measuring Receiver Frequency modulation (FM) Input level range RF: 100 kHz to 50 GHz –40 dBm to +30 dBm RF: 100 kHz to < 10 MHz 10 Hz to 10 kHz 3 Modulation rate range RF: 10 MHz to 50 GHz 10 Hz to 5 MHz 4 RF: 100 kHz to < 10 MHz max. 50 kHz (peak) Modulation deviation range RF: 10 MHz to 50 GHz max. 5 MHz (peak) RF deviation (peak) 200 kHz to 10 MHz 50 kHz ≥ 10 MHz 500 kHz (residual FM not included) RF modulation rate 200 kHz to 10 MHz 10 Hz to 10 kHz < 1 % ≥ 10 MHz 10 Hz to 100 kHz < 1 % FM deviation uncertainty 100 kHz to 200 kHz < 3 % AM rejection modulation rate: 400 Hz/1 kHz measurement bandwidth: 3 kHz AM modulation depth: 50 % RF ≥ 200 kHz < 20 Hz (nom.) measurement bandwidth: 3 kHz, detector: RMS RF: 300 kHz to 1 GHz < 1 Hz Residual FM RF: 1 GHz to 18 GHz < (0.25 + 0.75 × RF/GHz) Hz Harmonic distortion measurement bandwidth: 250 kHz or 10th harmonic, whichever is lower RF: 200 kHz to 10 MHz modulation rate: 50 Hz to 10 kHz < 10 kHz < 0.1 % (–60 dB) deviation < 50 kHz < 0.3 % (–50.5 dB) RF ≥ 10 MHz modulation rate: 50 Hz to 100 kHz < 100 kHz < 0.1 % (–60 dB) Total harmonic distortion of demodulated signal deviation < 500 kHz < 0.3 % (–50.5 dB) Distortion measurement see “Audio: Distortion and noise” section Detectors +Peak, –Peak, ±Peak/2, RMS, AVG (RMS sine wave calibrated) 3 Modulation rates ≥ 50 Hz with default settings, ≥ 10 Hz with meas. time ≥ 400 ms. 4 Modulation rates ≥ 50 Hz with default settings, ≥ 10 Hz with meas. time = 400 ms and demodulation bandwidth = 800 kHz. Version 09.00, July 2011 Rohde & Schwarz R&S®FSMR Measuring Receiver 9 Phase modulation (φM) Input level range RF: 100 kHz to 50 GHz –40 dBm to +30 dBm RF: 100 kHz to < 10 MHz 10 Hz to 10 kHz Modulation rate range RF: 10 MHz to 50 GHz 10 Hz to 5 MHz RF: 200 kHz to 10 MHz max. 1000 rad, depends on mod. rate φM deviation range RF: ≥ 10 MHz max. 10000 rad, depends on mod. rate Maximum phase deviation. RF modulation rate (residual φM not included) 200 kHz to 10 MHz 50 Hz to 10 kHz < 1 % φM deviation uncertainty ≥ 10 MHz 50 Hz to 100 kHz < 1 % AM rejection modulation rate: 400 Hz/1 kHz measurement bandwidth: 3 kHz AM modulation depth: 50 % RF ≥ 200 kHz < 0.02 rad (nom.) Residual φM measurement bandwidth: 100 kHz detector: RMS RF = 1 GHz typ. 0.003 rad Harmonic distortion measurement bandwidth: 250 kHz or 10th harmonic, whichever is lower RF: 200 kHz to 10 MHz modulation rate 50 Hz to 10 kHz < 0.1 % (–60 dB) RF ≥ 10 MHz Total harmonic distortion of demodulated signal modulation rate 50 Hz to 100 kHz <
本文档为【FSMR_dat-sw_en[1]】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_623604
暂无简介~
格式:pdf
大小:645KB
软件:PDF阅读器
页数:0
分类:
上传时间:2012-12-24
浏览量:15