WS6.3-1
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
July 2009
Inventory #002663
Chapter 6
Introduction to Hexa –
Workshop 3
3D Pipe Junction
O-grid Creation
ICEM CFD Introductory
Course
Introduction to Hexa – Workshop 3
WS6.3-2
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
July 2009
Inventory #002663
Training Manual3D Pipe Junction- Ogrid
3D Pipe Junction
– In this workshop, we will
import already created
blocking on 3D Pipe geometry.
– After checking the quality of
first mesh, we will create an O-
grid in the blocking to improve
mesh quality.
– Save the blocking.
Introduction to Hexa – Workshop 3
WS6.3-3
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
July 2009
Inventory #002663
Training ManualSet Working Directory
Set Working Directory
– File > Change Working Directory
– This will pop up a window. Select
the directory 3DPipeJunct where
initial project file has been saved.
• It provides access to selected
directory directly
• All output files will be saved in
same folder until user change the
location
Introduction to Hexa – Workshop 3
WS6.3-4
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
July 2009
Inventory #002663
Training ManualOpen Geometry
Open Geometry
– File > Open Geometry
– Choose “3DPipeJucnt.tin” file
– Click Open
Introduction to Hexa – Workshop 3
WS6.3-5
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
July 2009
Inventory #002663
Training ManualOpen Blocking
Open Blocking
– File > Open Blocking
– Choose “3DPipeJucnt.blk” file
– Click Open
Introduction to Hexa – Workshop 3
WS6.3-6
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
July 2009
Inventory #002663
Training ManualBlocking Strategy
Blocking strategy
– We have created Cartesian grid
in 3D pipe junction in previous
workshop.
– To improve the mesh quality and
capture the geometry we will be
creating the Ogrid in this
workshop and compare both the
Introduction to Hexa – Workshop 3
WS6.3-7
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
July 2009
Inventory #002663
Training ManualCompute Mesh
Compute Mesh
– Select Pre-Mesh in tree
– This will pop up and window
asking for re-compute mesh
– Click on Yes
– This will generate and
display Pre-Mesh
Mesh with 3.5 size
Introduction to Hexa – Workshop 3
WS6.3-8
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
July 2009
Inventory #002663
Training ManualQuality Check
Quality Check
– Select Blocking > Pre-Mesh
Quality Histogram
– Select Quality in Criterion
– Click Apply
– Right click on Histogram
and select Show. This will
display the selected
elements.
Elements
selected to show
Bad quality elements
are displayed
Introduction to Hexa – Workshop 3
WS6.3-9
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
July 2009
Inventory #002663
Training Manual
#1
#2
#3
#4
#5
O-Grid Creation
– Select Split Block > OGrid block
• Select highlighted two Blocks and
middle click to confirm.
• Select faces highlighted in blue color
to end ogrid there. Middle click to
confirm.
– Define Offset value
– Click Apply
• OGrid
– removes bad elements
– Captures geometry very well
– Generates high quality mesh
OGrid Creation
Introduction to Hexa – Workshop 3
WS6.3-10
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
July 2009
Inventory #002663
Training ManualPre-Mesh Params setting
Update Meshing Parameters
– Select Pre-Mesh Params >
Meshing Parameters
• Select Update All
• Click Apply
– This will update all the parameters
for Hex Meshing
– After modifying the blocking, it is
good practice to update meshing
parameters to get good mesh.
#1
#2
#3
#4
Pre-mesh without updating
meshing parameters
Pre-mesh after
parameter update
Introduction to Hexa – Workshop 3
WS6.3-11
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
July 2009
Inventory #002663
Training ManualQuality compare
Mesh Quality
– Mesh quality is improved
after ogrid creation
Initial
Determinant 2*2*2
Improved
Determinant 2*2*2
Initial Quality
Improved Quality
After Ogrid Creation
Before Ogrid Creation
Introduction to Hexa – Workshop 3
WS6.3-12
ANSYS, Inc. Proprietary
© 2009 ANSYS, Inc. All rights reserved.
July 2009
Inventory #002663
Training ManualSave Blocking
Save Blocking As…
– Select File > Save Blocking
As..
– Instead of saving project file
for each stage after few
operation user can save
blocking file only.
– Optimize the memory usage.
– Save modified blocking as
„3DPipeJunct_ogrid.blk‟
– Click Save.
本文档为【F3_WS3-3DPipeJunction_OgridV12】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑,
图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。