首页 京瓷1087所有代码(KYOCERA 1087 all the code)

京瓷1087所有代码(KYOCERA 1087 all the code)

举报
开通vip

京瓷1087所有代码(KYOCERA 1087 all the code)京瓷1087所有代码(KYOCERA 1087 all the code) 京瓷1087所有代码(KYOCERA 1087 all the code) KYOCERA 1087 collection Dong Zhihui @ 2006-08-29 10:14:41 Analog function access: boot 10871087 code copy key operation stop / clear 01 COPY key exit Simulation function Componen...

京瓷1087所有代码(KYOCERA 1087 all the code)
京瓷1087所有代码(KYOCERA 1087 all the code) 京瓷1087所有代码(KYOCERA 1087 all the code) KYOCERA 1087 collection Dong Zhihui @ 2006-08-29 10:14:41 Analog function access: boot 10871087 code copy key operation stop / clear 01 COPY key exit Simulation function Component code function, default value, part code function, default value U01 cancel analog operation, U54 adjuster, whole side blank edge The whole machine U02 not feeding, copying, U82 setting, optical components, fan control U03 copies the standard rate by U83, setting the temperature correction value of halogen exposure light U04 copies in different exposure proofs U97 the focal length of the lens set Paper and paper feed, U10 start, drive motor, drum charging and cleaning parts, U30 switch on main charging U11 check with paper transfer switch U31 to transfer the charge Exposure level switch U32 detects drum surface potential 5 carton lifting switch U40, adding powder to clean scraper, replacing scraper 4.5 mirror original position U42 light exposure light 4 Lens original position, U77 initialization drum drive time count, replace drum 3.5 the original position of the scanner is fixed, U46 is adjusted and the fusing temperature is adjusted 3 panel operation, U50 panel light is all bright 2.5 row of paper development, U60 initialize toner control voltage, replace carrier The U12 2 is forced to supply powder to the U61 Check clutch U62 related to paper and set control potential of each inspection toner Digital key paper clutch U80 detected AP powder voltage, select copy operation 1 initialize the U70 memory by initializing the bit memory 2 carton paper counting device, U71 setting maintenance counter preset value 3 manual paper exposure level description U15 adjusts the 1 maintenance counters of the copy paper at the counter roller, predetermined values 100 thousand and 10 thousand, 03 Exposure level instructions 1.5. Maintenance counters preset values 1000 and 10000 1 cartons 702 maintenance counters preset values 10 and 100 1.5 manual feeding 70 U72 setting maintenance count U16 pass test copy. Check paper twist, exposure level description The light halogen exposure lamp 1 on the optical system U20 maintains the counter predetermined values 100 thousand and 10 thousand, 00 U21 check scan operations 1.5 maintenance counters preset values 1000 and 10000 The U23 startup lens drives the electric 2 maintenance counter with predetermined values of 10 and 100 Exposure level description U74 card setting 1 move the lens to the set magnification position, exposure level instructions 1.5 move the lens in order to the standard magnification position. 1 cartons are 0 without paper U24 adjust exposure 1.5, manual paper feeding, no paper 0 Exposure level description 2 paper road jam 0 1 adjust manual exposure (EXP.1) 2.5 row of paper jams 0 4 adjust manual exposure (EXP.4) U76 set paper count 6 adjust manual exposure (EXP.6) exposure level instructions U25 adjust the lateral magnification cartons 1.0100000 and 1000000 Exposure levels are illustrated in 1.51000 and 10000 1 adjust the original position 2.010 and 100 of the lens 1.5 enlarge and copy, adjust lens position, hand feed 2.5100000 and 1000000 2 reduce the copy, lens position 3.01000 and 10000 2.5 zoom in and out, adjust the focal plane 3.510 and 100 3 reduce the copy, adjust the focal plane, copy mode, U84 settings, automatic cleaning time 3 U26 adjust the vertical magnification U85, set the automatic holding time of 0 U27 adjust the alignment of the guide edge Exposure level description U86 set automatic shutdown time 0 1 carton U93 setting memory switch 1 U29 adjust exposure / exposure level instructions on / off copying Exposure level description 1 total count for double count / single count 1 One 0 adjust, enlarge, copy (200%) exposure 1.5 1.5 adjust and reduce exposure (250%) when copying (2) exposure level (level 13) 0 Fault code Code function, content code, function content C01 is prepared from memory data U70, motherboard C64 fuser thermistor / temperature too high C21 drive motor U10, motor, control panel, C72 drum thermistor C31 scanning system steel wire, connector, sensor, C73 drum thermistor circuit breaker C41 lens, motor, motor, connector, sensor OP front door cover is not closed C42 Mirror Motors, motors, connectors, sensors, U1 options, key counter, incorrect installation C51 main charge / high voltage transformer electrode wire leakage, AP began to replenish toner C52 transfer / high voltage transformer leakage...... The copier is in thermal insulation C61 fix heater, UF (flashing), put in toner bottle, not to us C63 fixing thermistor Entry mode is 10871087 U000 output self status report- U001 quit maintenance mode- U004 check machine numbers- U005 no paper copy- U019 displays the ROM version- U020 initializes all data- U021 initializes memory- U030 check motor operation- U031 checks the paper transfer switch- U032 check clutch operation- U034 sets the image print alignment Adjust front end alignment 5.1/0/0/0/0/0 Adjust midline -1.2/0/0/0/0/0 U035 sets the folio size Length 330 Width 210 U051 adjust paper tightness 20/0/70/80/80/0 U053 trim motor speed Drive motor speed regulation 0 Multilateral motor speed regulation 0 Paper motor speed regulation 0 Speed regulation of the counter roller motor 0 Motor speed adjustment (for hand feed paper feed) 0 Motor speed adjustment (for the purchase of paper supplied in the carton) 0 Motor speed regulation (double sided mode) 0 U060 adjust scanner input characteristic 12 U061 turn on the exposure light- U063 adjust the shade position 0 U065 adjust scanner magnification Main scan direction 0 Sub scanning direction -12 U066 adjust the front end alignment to the manuscript 10 on the scanner glass U067 adjust the center line to scan the manuscript on the stage glass. 0 U068 adjusts the scanning position of the manuscript of the manuscript feeder 0 U070 adjust the magnification of the manuscript feeder 0 U071 adjusts the scanning position of the send writer Adjust front end alignment 0 Adjust rear end alignment 0 U072 adjust the feeder line 0 U073 check scanner operation- U074 adjust the input brightness of the manuscript feeder 1 U087 turn on / off the scanner position adjustment mode 35 U088 sets the input filter (moire fringe reduction mode) off U089 output MIP-PG pattern- U091 check the shading- U092 automatic adjustment scanner- U093 sets the exposure concentration level Text / text and picture / picture mode 0/0/0 U099 check manuscript size check- U100 sets the main charging high voltage The grid control voltage is 135 The copy interval is 60 Copy number 50 Correction number 10 U101 sets other high voltage Development bias clock frequency 27 Development bias clock duty 45 Transfer control voltage (larger size) 168 Transfer control voltage (smaller size) 179 The transfer charge output closes off timing 38 Transfer charge output open timing 34 Separation control voltage 1 Separate charge output open timing 33 The separation charge output closes off timing 43 U110 check / clear drum count- U130 toner mount mode- U144 set toner loading operation 0 U158 check / clear development count- U161 sets the fuser control temperature The primary stabilizing temperature is 140 The two stable fusing temperature is 160 Copy operation temperature 1170 Copy operation temperature 2180 The number of paper used for fixing control 5 ? for fixing control paper (paper) number 20 U162 forced stable fixation- U163 resets the data for fixing faults- U167 check / clear fixing count- U199 check the fusing temperature- U200 opens all LED- U202 sets the KMAS master monitor system- U203 operates the manuscript feeder individually- U204 sets whether there is a key count card or a key counter U207 check the operation panel key- U243 inspect the manuscript, the motor and the electromagnet- U244 check each switch for the manuscript feeder- U250 set maintenance cycle 150000 U251 check / wipe count 0 U252 setting the region of Japan U253 switches between single and double counts A3 U254 on / off automatic start function U255 set auto clearing time 90 When U258 detects that the toner is exhausted, switch the copy operation sheet mode U260 change copy count time after paper out U265 setting geographical specifications 0 U332 set size conversion factor 1 U342 sets the paper limit to open U345 sets maintenance expiration indication value- U402 adjust the reserved edge of the image printing- U403 adjust the manuscript scanning on the stage glass and reserve the binding edges- U404 adjust the manuscript scanning in the manuscript sending device and reserve the binding edge- U407 adjust memory, image print, front alignment- U901 check / clear the copy count of each paper position- U903 check / clear card count- U904 check / clear fault display count- U905 check / clear the send writer count- U908 check total count- U910 clear coverage data- U911 check / clear copies of various paper sizes- U927 clear counter- U928 check / clear machine running count- U990 check / clear the time of the exposure light- U991 check scanner count- U993 output VTC-PG pattern-
本文档为【京瓷1087所有代码(KYOCERA 1087 all the code)】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_037433
暂无简介~
格式:doc
大小:33KB
软件:Word
页数:10
分类:生活休闲
上传时间:2018-02-04
浏览量:57