首页 emc79101 - How to break out of an endless reboot loop on a CX-Series array

emc79101 - How to break out of an endless reboot loop on a CX-Series array

举报
开通vip

emc79101 - How to break out of an endless reboot loop on a CX-Series arrayemc79101 - How to break out of an endless reboot loop on a CX-Series array How to break out of an endless reboot loop on a CX-Series array How to force the reboot count to greater than four to break out of an endless reboot loop on a CX-Series array Produ...

emc79101 - How to break out of an endless reboot loop on a CX-Series array
emc79101 - How to break out of an endless reboot loop on a CX-Series array How to break out of an endless reboot loop on a CX-Series array How to force the reboot count to greater than four to break out of an endless reboot loop on a CX-Series array Product: CLARiiON CX200 Product: CLARiiON CX200LC Product: CLARiiON CX400 Product: CLARiiON CX600 CX-Series array appears stuck in endless reboot. Endless reboot loop From time to time, a CX-Series array can get stuck in a seemingly endless reboot loop. Although the software has failsafe mechanisms to protect against this, occasionally the timing of certain panics may occur after the reboot count has been cleared, thus defeating the failsafe mechanisms. Contact your support provider for assistance. Support personnel can use a procedure to break out of the reboot loop so the problem can be debugged. The procedure requires logging in to the storage processor (SP). For Technical Support Personnel. This procedure works on all CX arrays, but there is an easier procedure starting in r12.: 1. Bring up a HyperTerminal window to the SP in question. 2. Break into the power-on self test (POST) by hitting when the alphabetic portion starts displaying. 3. Enter the POST password ("GO_sox" or "DB_key" - depending on your revision of POST). 4. Select "Enter Debugger" from the Debugger prompt and enter: "mm ffe80004" 5. Type "5 ." Note: After you enter "mm address" to modify a memory address in Step 4, you must enter a value. The value in this case is any number greater than 4. When you enter 5, ("5 ."), the dot terminates the line. 6. Type: menu 7. From the menu, select "reboot SP." 8. The SP should come up in degraded mode. 1. The POST password should be SHIP_it (R12 or newer) or DB_key (R11 or older) 2. The only problem with this method is that it may not work if you are in the middle of an NDU. Beginning in R13, you can modify a different address to explicitly "force degraded mode". TS2 may contact engineering for this information.
本文档为【emc79101 - How to break out of an endless reboot loop on a CX-Series array】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_219945
暂无简介~
格式:doc
大小:35KB
软件:Word
页数:0
分类:生活休闲
上传时间:2019-01-09
浏览量:11