电除尘高频电源改造节能分析电除尘高频电源改造节能分析 翟永骞 国电荥阳煤电一体化有限公司,450100 The analysis of the reconstruction of the electrostatic precipitator’s high-frequency power Yongqian Zhai Guodian Xingyang Power&Coal co.,LTD,450100 ABSTRACT: As an important part of environmental protection in powe...

电除尘高频电源改造节能分析
电除尘高频电源改造节能 分析 定性数据统计分析pdf销售业绩分析模板建筑结构震害分析销售进度分析表京东商城竞争战略分析 翟永骞 国电荥阳煤电一体化有限公司,450100 The analysis of the reconstruction of the electrostatic precipitator’s high-frequency power Yongqian Zhai Guodian Xingyang Power&Coal co.,LTD,450100 ABSTRACT: As an important part of environmental protection in power station, electrostatic precipitator is high energy-consuming equipment. In today's sustainable development environment, its working condition has an important impact on the unit’s stable and economic operation. In order to achieve higher collection efficiency and lower power consumption, the power plants all take various measures and new technologies, so that the equipment reduces dust emissions and energy consumption. High-frequency power is a power device of the new generation of the electrostatic precipitator. Compared to the currently used frequency power, it can improve the efficiency of electrostatic precipitator. More importantly, it is able to significantly reduce the power consumption. Key words: electrostatic precipitator;high-frequency power;reconstruction;higher efficiency; lower power consumption 摘要:电除尘器作为电厂环保的重要环节之一,是火力发电厂重要的环保设备,属于高耗能的设备。在当今可 持续发展的大环境下,其工作状况的好坏,对机组的稳定运行和经济性有着重要影响。为了达到更高的除尘效率 和更低的电耗,各发电厂皆采取各种措施和新技术,就是为了减少烟尘排放,减少能耗。大功率高频电源是新一 代电除尘器供电装置,与目前使用的工频电源相比,可以提高电除尘器的除尘效率,更重要的是能够大幅减少电 除尘电耗。 关键词:电除尘器;高频电源;设备改造;高效率;低能耗 1引言 是高压电源的特点,利用春节调停机会,对#2 我公司#1、#2机于2010年底先后投运,2电除尘进行了高频电源改造。经过一段时间的 台电除尘能耗偏高,效率未能达到设计要求。运行,通过对电除尘运行中的主要数据进行统 为提高除尘效率、减少污染物排放,更是为了计,对未改造的#1机电除尘和改造后的#2机 降低电除尘能耗,针对电除尘器主要电能消耗电除尘的能耗、厂用电率等指标进行节能效果 比较。 器。高频电源系统原理框图见图1。 三2高频电源的改造 全桥EMI相三相输入输 滤波器逆变整流滤波2.1改造前设备概况 入 我公司一期(2×600MW) 工程 路基工程安全技术交底工程项目施工成本控制工程量增项单年度零星工程技术标正投影法基本原理 每台炉配备 浙江信雅达环保工程有限公司生产的两台高压谐振输出除尘器 网络变压器整流桥负载2SY521-4型双室四电场电除尘器,电场有效 断面积2×520.8m2,单台处理最大烟气量 辅 驱动保护电路温度检测电路助1677280m3/h,设计除尘效率?99.76,。除尘 电DSP信号采样、隔源 控制系统离、调理电路器电源为浙江信雅达环保工程有限公司的 GGAJO2-2.2A/72kV型电除尘器高压电源(12 图1 高频电源系统原理框图 台)和GGAJO2-2.0A/72kV型电除尘器高压电 2.4改造过程 源(4台),控制系统采用大连电子研究所生产 由南京国电环保设备有限公司利用#2机DDL06节能专家系统。电除尘器低压系统采 小修时间,对#2机电除尘进行了高频开关电源用PLC(AB公司)控制。 改造工作,主要包括原16台整流变及电缆的 #1、2机电除尘实际运行中电耗每台大约 拆除,原16台高压控制柜的改造以及16台高在1400kW左右。 频开关电源及动力电缆、通讯电缆的安装敷设2.2改造方案 工作。工期约14天,改造结束后进行了空载1) 高频电源供电装置代替原工频电源的高压 升压试验合格。 #2机组启动后,电除尘投入控制柜、整流变压器。将原除尘器顶部的16 运行,除尘效果良好。 台整流变压器拆除,在整流变压器位置上安装 3效果和效益 上高频电源,并将原先16台高压电源控制柜3.1效果 拆除,在原有位置上增加高频电源配电柜。 1) 2011年2月底,我厂委托南京电力设备质) 将原上位机拆除,重新建立上位机系统。 2量性能检验中心来我厂对#2电除尘进行性能3) 低压系统保持不变。 试验(检测报告 2.3高频电源原理 NICE/P/2011-J10048-04-0207),检测报告显 高频电源是将三相交流电经整流和滤波 示:#2电除尘除尘效率99.8%。 后得到约530V左右的直流电压,经全桥逆变, 2) 由于电除尘每台电场电源处无计量点,电形成20kHz左右的交变电流,再经高频变压器 除尘电耗以主厂房6kV配电室内A、B电除尘升压整流后形成高频高压脉动直流送电除尘 变压器6kV侧的电度读数为依据,电度读数来 自综合保护装置,精度0.5级。为使数据有可电量56.7%。现上网电价为0.4112元/kWh,每 比性,特选取两台机发电量极其接近的月份月可节约757*24*30*0.4112/10000=22.41万 (2011年3月);为使数据有代 关于同志近三年现实表现材料材料类招标技术评分表图表与交易pdf视力表打印pdf用图表说话 pdf 性,选取较元。按设计年运行5500小时计算,一台机电 长的时间段(31天)为 样本 保单样本pdf木马病毒样本下载上虞风机样本下载直线导轨样本下载电脑病毒样本下载 。两台机电除尘电除尘全年节约757*5500*0.4112/10000=171.2 耗数据见表1。 万元。 4.节能原理分析 表1 #1、2机电除尘电耗数据 4.1电场参数 项目 3月 为找出节电原因,选取#1、2机日负荷曲 #1机 29498.062 发电量(万kWh) 线最相似一天(2011年4月26日)的电除尘#2机 29580.804 详细数据进行比较。#1电除尘器A侧1室1、#1机 66.08 负荷率(%) #2机 66.265 2电场参数见表2,#2电除尘器A侧1室1、2 #1机 99.3 电除尘电耗(万kWh) 电场参数见表3。 #2机 43 #1机 0.337 电除尘电耗率(%) 表2 4月26日#1电除尘器A侧1室1、2电场参数 #2机 0.146 由表1可以得出: #1、 2机3月份发电 量相差百分数为(29580.80-29498.06) *100/29580.80=0.28%, 在3月份发电量几乎一样的情况下(仅相项目 A11 A12 时间 负荷MW I1(A) U1(V) I2(mA) U2(kV) 火花率 I1(A) U1(V) I2(mA) U2(kV) 火花率 差0.28%),#2电除尘器比#1电除尘器月节电:0:00 672 54 29 251 166 796 49 0 436 256 194 2:00 640 55 24 273 167 820 47 0 435 213 168 99.304-43.085=56.219万kWh 4:00 652 54 26 270 168 842 47 0 415 179 154 #1电除尘器电耗功率6:00 988 58 28 260 165 816 48 0 501 242 178 8:00 563 57 29 258 168 796 47 0 564 136 140 99.3/31/24*10000=1335kW 10:00 728 60 28 248 170 802 49 0 583 256 168 12:00 664 60 28 254 166 788 49 1 589 251 125 #2电除尘器电耗功率43.0 14:00 277 150 899 58 27 277 189 897 47 0 590 kW /31/24*10000=57816:00 590 242 201 1072 62 28 238 168 796 50 0 18:00 590 217 137 628 60 28 238 169 780 50 0 #2电除尘器比#1电除尘器节电:(1335-578)20:00 580 155 149 900 59 29 259 170 796 48 0 22:00 527 185 167 460 50 29 244 166 786 49 0 *100%/1335=56.7% 3.2效益 由以上数据得出:#2炉电除尘电源改造 后,电除尘功率可减少757kW,比改造前节约 表3 4月26日#2电除尘器A侧1室1、2电场参数 300 250 200 150#1 #2项目 A11 A12 100时间 负荷MW I1(A) U1(V) I2(mA) U2(kV) 火花率 I1(A) U1(V) I2(mA) U2(kV) 火花率 0:00 546 406 41 0 31 534 330 39 0 429 34 50 2:00 534 415 40 0 30 539 336 36 0 407 35 4:00 34 540 414 40 0 30 545 334 37 0 412 0(A)6:00 35 554 413 41 0 31 542 338 38 0 489 0:00 8:00 36 557 409 42 0 32 548 339 38 0 563 2:0010:00 36 555 412 42 0 33 552 338 38 0 593 12:00 37 554 412 43 0 32 544 338 39 1 4:00591 图2 #1、2电除尘1室1电场4月26日一次电流曲14:00 38 540 420 40 0 30 538 327 38 0 583 6:0016:00 37 559 396 45 0 32 546 342 40 0 586 线 8:0018:00 37 554 407 44 0 32 544 337 40 0 590 10:0020:00 36 555 410 44 0 32 544 335 39 0 581 7022:00 36 559 409 42 0 31 545 339 38 0 502 12:00 6014:00 16:0050 18:0040 20:00 30#122:00#2204.2电场参数对比 101) 选取#1、2电除尘1室1电场不同负荷下、 024小时的一次电流进行比较,发现在不同负荷(kV)0:00 下,#2电除尘各电场一次电流波动不明显,而 2:00#1电除尘各电场一次电流波动非常显著,见图4:00图3 #1、2电除尘1室1电场4月26日二次电压曲 线 2; 6:00 8:002) 选取#1、2电除尘1室1电场不同负荷下、3) #2电除尘1电场火花率基本为0, #1电除10:0024小时的二次电压进行比较,发现在不同负荷尘1电场火花率接近30次。 12:00下,#2电除尘各电场二次电压都低于#1电除14:004.3结果分析 16:00尘各对应电场二次电压约10kV,20kV,见图1) 高频电源可增大电晕功率,增加电场粉尘 18:003。 的荷电效果,较好的荷电效果使极板吸附能力20:00 增强,除尘效率提升,不需要过高功耗就可以 22:00 首选高频电源,这样就一劳永逸,避免浪费。 达到效果,因而耗电较少;高频电源在纯直流 参 考 文 献: 供电方式时电压平稳、波动小;两个特点反应 [1] 中国环保产业协会电除尘委员会.瞄准节能减排,积极推 进电除尘电源技术创新[N].中国环境报, 在一次电流上,就是电流值较小,波动较小。 2010-12-20(5) [2] 黎在时.电除尘器的选型安装与运行管理[M].北京:中国2) #1电除尘的火花率较高,是为了保有较高电力出版社. 2005.224-227. [3] 陈颖,郭俊,卢刚等.电除尘高频电源的研制与应用[D]. 电压来保证除尘效率。这样较高的火化率,直石家庄:第12届全国电除尘学术会议论文 集.2007.10.329-332. 接导致高电耗;还有就是调整要在就地电源柜[4] 张谷勋,蒋云峰.电除尘器电源的发展方向—高频化和数 字化[J].电源世界,2007,10(1):1,4. 上进行,不方便运行人员操作。高频电源可以作者简介: 翟永骞(1969-),男,工程师,国电荥阳煤电一体化有限公司电保证除尘高效率情况下控制火花率为0,且调气主管,sdlczyq@163.com。 整可以在DCS上进行,操作简单,使得火花 及时得到控制,火花能量也很小,这样,电场 恢复快从而进一步提高了电场的平均电压,提 高除尘效率,也达到了节电效果。 5.结论 5.1高频电源输出电压为纯直流,电晕放电强 烈,电场强度高,烟尘粒子荷电量大,除尘效 率明显优于传统工频电源。 5.2工频电源改造为高频电源供电后,输出电 压可稳定在火花电压的临界值,可以保持0火 花率;又因为尘粒荷电量大,较低的功耗即可 达到除尘效果,节电效果显著,能够省电50% 以上。 5.3改造后电除尘的调整都是在控制室内微机 上进行,操作简单、直观、方便。 6问题与建议 6.1低压部分未改,阴、阳极振打等仍采用原 程序,原程序设定振打次数是根据原设备除尘 原理来设定的。建议只改造高频电源的,应对 低压部分进行优化,除尘效果会更好,也更能 节约电耗。 6.2由于只改造了高频电源部分,它与低压部 分的控制分别为不同公司提供的系统控制,运 行人员监控的微机数量过多,劳动量大,而且 不利及时发现问题。 6.3高频电源改造是在投产不到2个月进行的, 造成了一定投资浪费。建议新建电除尘器应当
本文档为【电除尘高频电源改造节能分析】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_421808
暂无简介~
格式:doc
大小:25KB
软件:Word
页数:0
分类:建筑/施工
上传时间:2017-10-08
浏览量:48