GJB151A-97
標準編號 標準名稱 國際標準號
GJB151A-97 MIL-STD-461A 軍用設備和分系統電磁發射和敏感度
要求
对教师党员的评价套管和固井爆破片与爆破装置仓库管理基本要求三甲医院都需要复审吗
RADIOING.com - eEngineer
Overview
MIL-STD-461A: Electromagnetic Interference (EMI) Characteristics Requirements for
Equipment (08/01/68)
Establishes requirements and test limits for the measurement and determination of EMI
emissions and susceptibility characteristics of electronic, electrical and electromechanical
equipment. The requirements are applied for general, multi-service procurements and
single service procurements, as specified in individual equipment specifications, contracts,
and orders.
Conducted Emissions
CE01: 30 Hz - 20 kHz (Power Leads)
CE02: 30 Hz - 20 kHz (Control/Signal Leads)
CE03: 20 kHz - 50 MHz (Power Leads)
CE04: 20 kHz - 50 MHz (Control/Signal Leads)
CE05: 30 Hz - 50 MHz (Inverse Filter Method)
CE06: 10 kHz - 10 GHz (Antenna Terminals)
Conducted Susceptibility
CS01: 20 Hz - 50 kHz (Power Leads)
CS02: 50 kHz - 400 MHz (Power Leads)
CS03: 15 kHz - 10 GHz (Intermodulation)
CS04: 15 kHz - 10 GHz (Undesired Signal Rejection) CS05: 15 kHz - 10 GHz (Cross Modulation)
CS06: N/A (Spikes - Power Leads)
CS07: N/A (Squelch Circuits)
CS08: 30 Hz - 10 GHz (Undesired Signal Rejection)
Radiated Emissions
RE01: 30 Hz - 50k Hz (Magnetic Field)
RE02: 14 kHz - 10 GHz (Electric Field - Power Leads & Cables) RE03: 10 kHz - 40 GHz (Ant. Spurious & Harmonics) RE04: 20 Hz - 15 kHz (Magnetic Field)
RE05: 150 kHz - 1 GHz (Vehicle & Engine Eqpt.)
RE06: 14 kHz - 1 GHz (Overhead Power Lines)
Radiated Susceptibility
RS01: 30 Hz - 30 kHz (Magnetic Field - Eqpt & Cables) RS02: Powerline & Spike (Magnetic Induction - Eqpt & Cables) RS03: 14 kHz - 10 GHz (Electric Field - Eqpt & Cables) RS04: 14 kHz - 30 MHz (Parallel Line Fields)