首页 CKD 真空开关

CKD 真空开关

举报
开通vip

CKD 真空开关 2CC-825A DIGITAL PRESSURE SENSOR PPX SERIES Digital pressure sensor PPX series Easy to check with dual digital display! New product New easy-to-use high-function digital pressure sensor PPX series with dual display to check (current value) and (set val...

CKD 真空开关
2CC-825A DIGITAL PRESSURE SENSOR PPX SERIES Digital pressure sensor PPX series Easy to check with dual digital display! New product New easy-to-use high-function digital pressure sensor PPX series with dual display to check (current value) and (set value) of pressure at the same time, 3-color display, copy function of setting details, and 3-mode setting, etc. Compact size of 30 X 25.5 Digi ta l pressure sensor Easy to check with dual digital display!Easy to check with dual digital 30mm 25.5mm Direct setting with dual display The main screen to display "current value" and the sub screen to display "set value" are compactly incorporated. The set value can be adjusted and set with [current value] displayed. The screens turns ON/OFF during setting, so usable as volume type sensor. Key lock is also equipped. Comparison output 1 operational indicator light Mode switchover key Setting DOWN key Setting UP key Current value [Main display section] Set value [Sub-display section] (High function type having analog voltage output operation display) Comparison output 2 operational indicator light 3-mode setting to match applications The operation mode is designed ac- cording to setting applications as daily operation setting "RUN MODE", basic setting "MENU MODE" and high func- tion "PRO MODE". Operation and setting are very easy. PRO MODE High-function setting such as copy function and sub-display section change is possible. MENU SETTING MODE Basic setting such as output mode setting and NO/NC switching is possible. RUN MODE Setting adjustment and key lock, etc. are possible during operation. Easy to check with dual digital display!display! The main display section is changed to green/red in accordance with out- put ON/OFF, and orange during setting. The sensor state is easily read. Output ON/OFF: (green/red) During setting: (orange) The copy of sensor setting details can be quickly made to other sensors with data communication. Problems caused by incorrect in- stallation is prevented if the same setting is applied to several units. Make a copy of details. Setting copy Setting copy Setting copy Setting master Unit switching available (MPa, kPa, kgf/cm2, bar, psi, mmHg, inchHg) Alphabet and number other than the setting can be displayed in the sub-display section. Troubles of putting labels such as normal pressure range and equipment No. are saved. 2 independent comparison outputs are provided, so either detection mode can be selected. [3 detection mode] EASY MODE ON/OFF control of comparison output Hysteresis mode ON/OFF control with hysteresis setting of comparison output Window comparator mode Comparison output ON/OFF control within set pressure range Comparison output Analog voltage output External input Low pressure type: 1 to 5V and high pressure type: 0.6 to 5V Auto-reference/remote zero adjust Selection High-function type to select analog voltage output or external input instead of comparison output in the other side is available to meet different applications. Easy-to-read alpha-numeric display Alpha-numeric with 12-segment is provided. Alphabet and number are easily read. Peak/bottom hold Maximum and minimum values of fl uctuated pressure is displayed with using two screens. Response time change possible with 10 steps (2.5ms to 5000ms) Setting details display possible with code no. Energy saving mode equipped Power consumption reduced by 30 to 40% (with lower brightness of display section and turning off the light) Space saving Contact installation possible 3-color display (red/green/orange) Copy function to reduce man-hours and to prevent mistake Customized sub-display section Model for foreign markets available CE Marked products RoHS directive compliant Independent two outputs are equipped (standard type) High-function type meeting different applications Easy to operate Intro 1 Digital pressure sensor applications Positive pressure and vacuum confi rmation or interlock Leakage inspection (high-function type) VRA2000 RP PPX PPX PPX Easy setting with auto-reference/remote zero adjusting• PPX Manifold Both vacuum pressure and break pressure can be controlled with a single unit. PPX Tension controlling buffer FBU2 PPX Contact confi rmation PPX When designing and manufacturing a device using CKD products, the manufacturer is obligated to check that device safety mechanical mechanism, pneumatic control circuit, or water control circuit and the system operated by electrical control that controls the devices is secured. It is important to select, use, handle, and maintain the product appropriately to ensure that the CKD product is used safely. Observe warnings and precautions to ensure device safety. Check that device safety is ensured, and manufacture a safe device. Always read this section before starting use. Safety precautions WARNING This product is designed and manufactured as a general industrial machine part. It must be handled by an operator having suffi cient knowledge and experience in handling. Use this product in accordance of specifi cations. Contact CKD when using the product outside the unique specifi cations range, when using it outdoors, and when using it under the conditions and environment below. Do not attempt to modify or additionally machine the product. Use for special applications requiring safety including nuclear energy, railroad, aviation, ship, vehicle, medical equipment, equipment, or applications coming into contact with beverage or food, amusement equipment, emergency shutoff circuits, press machine, brake circuits, or for safeguard. Use for applications where life or assets could be adversely affected, and special safety measures are required. Do not handle, pipe, or remove devices before confi rming safety. Inspect and service the machine and devices after confi rming safety of the entire system related to this prod- uct. Note that there may be hot or charged sections even after operation is stopped. When inspecting or servicing the device, turn off the energy source (air supply or water supply), and turn off power to the facility. Discharge any compressed air from the system, and pay enough attention to possible water leakage and leakage of electricity. When starting or restarting a machine or device that incorporates pneumatic components, make sure that the system safety, such as pop-out prevention measures, is secured. Observe warnings and cautions on the pages below to prevent accidents. DANGER: When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries, or when there is a high degree of emergency to a warning. WARNING: When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries. CAUTION: When a dangerous situation may occur if handling is mistaken leading to minor injuries or physical damage. Note that some items described as "CAUTION" may lead to serious results depending on the situa- tion.In any case, important information that must be observed is explained. Intro 2 Observe corporate standards and regulations, etc., related to the safety of device design and control, etc. ISO4414, JIS B 8370 (pneumatic system rules) JPAS 005 (principles for pneumatic cylinder use and selections) Such as High Pressure Gas Maintenance Law and Occupational Safety and Sanitation Laws, other safety rule and corporate standards and regulations The safety cautions are ranked as "DANGER", "WARNING" and "CAUTION" in this section. Care must be taken in not exceeding media and ambient temperature range in cluding pipng area. Do not use the product in locations that water or oil may contact the products. Pneumatic components (electronic pressure switch and sensors) Design & Selection Always read this section before starting use. Refer to "Pneumatic, vacuum and auxiliary components CB-024SA". Safety precautions WARNING Use this product in accordance of specifi cations. Applications, load current, voltage, temperature, shock and working environment, etc. exceeding the specifi cations range could lead to destruction and malfunction of periph- eral equipment. Do not use oxygen, corrosive or combustible gas, or toxic fl uid for this product. The pressure switch is not explosion proof. Do not use this product in fl ammable atmosphere, or explosions could oc- cur. Do not use this product in fl ammable atmo- sphere The internal pressure in the closed chamber could change if the fl uid leaks in an accident. Use this product in the con- trol box with safety device to control internal pressure, or indoors with no pressure differential from the outside. Do not install the product in completely sealed enclosure. Power voltage Use the product within the specifi ed power voltage range. If voltage exceeding specifi ed rage is applied, or alternating cur- rent power (100 V AC) is applied, circuit damage could occur. Load short circuit Do not short-circuit the load, or circuit damage could occur. Incorrect wiring Avoid incorrect wiring such as connecting to the wrong electrode of the power source, etc., or the circuit damage could occur. CAUTION Working fl uid When using working fl uid other than air; nitrogen gas, etc., oxygen defi ciency could be caused. Observe the following in- structions. Use this product in well ventilated location. Ventilate the work area when nitrogen gas is being used. Inspect piping regularly, so nitrogen gas does not leak. If this product is used for vacuum suction confi r- mation, care must be taken for following matters. The pressure exceeding withstanding pressure in the speci- fi cations must not be applied to the product if positive pres- sure of vacuum break is applied. Working environment Avoid use in the place that vibration or shock not less than 100m/s2 is applied. Considering errors, etc. caused by precision/ temperature characteristics, decide the setting. When a pressure switch is used to issue interlock signals, if high reliability is required, provide mechanical guards for a failure, or provide dual interlock as a switch (sensor) other than pressure switch is used. Execute inspection regularly to check that the normal operation is done. Care must be taken when this product is used in an interlock circuit. Responsiveness is adversely affected depended on working pressure and volume of loads. Install a regulator before the sensor if stable repeatabil- ity is required. Use conditions to comply with CE marking PPX series is CE marked products complied with EMC di- rective. EN61000-6-2; regulation matched to immunity ap- plies to this product. Conditions below are necessary to comply with these standards. Conditions Length of power line connected to the sensor is to be less than 10m. Provide a line fi lter in AC power line. Do not share power with an inverter or components causing motor noise, etc. Remove noise from inductive load (such as solenoid valve and relay) with a surge suppressor such as CR or diode in the source side. When using components (such as switching regulator and inverter motor) causing noise around the sensor installation section, ground a frame ground (F.G.) terminal of compo- nents. Keep distance between a line connected to sensors and strong magnetic fi eld. Connect a line connected to sensors with shield wire. Connect shield wire to the ground of power side. Take the following countermeasures to prevent malfunction caused by noise. When the secondary side control pressure is re- leased to atmosphere as air blow, pressure may fl uctuate depended on piping and blow condi- tions. Execute a test under actual working condi- tions or contact to CKD. Select the product whose fl ow is not less than the total of that used for sensors when selecting a dryer, an air fi lter, an oil mist fi lter and a regula- tor. Intro 3 PPXSeries Installation & Adjustment WARNING Avoid incorrect connection. An incorrect connection may cause a fatal error not only to this product but also peripheral devices. DC power not insulated from AC primary side may damage the product and power, so an elec- tric shock could occur. Do not use the product in this case. If a switching regulator at store is used for power, ground a frame ground (F.G.) terminal of power. CAUTION Do not use the product where the product is exposed to direct-sunlight, or may come in contact with water or oil. Avoid use in high steam and dirt environments. Care must be taken to avoid product contact with or- ganic solvents such as thinner, water, oil and fat. Do not put wire, etc. into the pressure port, or diaphragm may be damaged to prevent a normal operation. Performance could not be guaranteed in strong electromagnetic fi eld. Flash air pipe connected to sensors before con- necting. Prevent pipe from catching tips of seal- ing tape when piping. Apply adequate torque when connecting pipes. Tighten by hand at fi rst, then use a tool to prevent screw thread damaged. Set screw Tightening torque N·m M3 0.3 to 0.6 M5 1 to 1.5 Rc1/8 3 to 5 Apply a 12mm spanner (14 mm for PPX-6G type) on the pressure port hexagon head section to fi x, then apply tightening torque 9.8N·m or less if a joint at store is connected to the pressure port. A joint or the pressure port section could be broken if too much torque is ap- plied. Use seal tape to connect joints to prevent air leak. 12mm spanner WARNING Sensor bracket PPX-KL is available. If a sensor is installed with a bracket, etc., tight- ening torque must be 0.5N·m or less. M3 (length 6mm) Cap screw (Included in PPX-KL) Sensor bracket PPX-KL (optional) Panel bracket PPX-KHS (optional) Front cover PPX-KCB (optional) Panel bracket PPX-KHS (optional) and front cov- er PPX-KCB (optional) are available. Intro 4 Piping Installation Precautions PPXSeries Insert cable with connector PPX-C* into the connector section of this product as right when connection. Pull out the connector while pressing the jaw of cable with connector when disconnecting. If the cable section is pulled out without pressing the jaw when disconnecting, the cable or connector could be bro- ken. Installation & Adjustment CAUTION Care must be taken for protection of body and lead wire. Do not apply stress to cable outlet or connector section directly. Cable with connector (PPX-C*) Do not dent or drop the body. Do not apply excessive re- peated bending force and tension to lead wire, or could re- sult in disconnection. Connect an elastic material as a cable bearer to the mov- able part. Connector wiring Connector pin No. Terminal name +V Comparison output 1 Standard type: Comparison output 2 High-function type: Analog voltage output or external input 0V Use an applicable cable and crimp tools for housing and contact if connected with the connector set (PPX-CN). Lead wire diameter Lead wire Conductor cross-section areas Conductor cross- section areas 0.12 to 0.32mm 2 (AWG26 to 22) Lead wire diameter 1.0 to 1.5mm Wire Annealed copper twist wire Housing JST MFG CO. LTD. PAP-04V-S Contact JST MFG CO. LTD. SPHD-001T-P0.5 Recommended crimp tools JST MFG CO. LTD. YC-610R (AWG26 to 24) JST MFG CO. LTD. YC-611R (AWG22) Wiring Connect cable with power turned OFF. Discharge static electricity charged in human body, tool or equipment before and during operation. Use safety power supply with ripple voltage 10% or less without noise. Voltage 24V Ripple ratio 10% =10% of 24V=2.4V 2.4V Time Voltage must rise or fall quickly when power is turned ON or OFF. If the rated voltage is not reached, the sensor could malfunction. In some cases, the sensor could not recover after the rated voltage is reached. Reset the power in that case. Even if the voltage drops temporarily, shout down the power once, then turn ON the power again. Avoid use during the transient state (0.5s) when power turned ON. Install the product and wiring as far as possible from noise source such as a strong electric line, etc. Take other coun- termeasures for the surge from inductive loads on the power line. Do not operate the control unit, machinery or equipment suddenly after wiring. Due to wrong setting, signals not ex- pected could be outputted. First stop control unit, machinery and equipment, while energize these to test. Set the target setting after test. Cable with 0.3mm2 and over can be extended up to 100m. Note that the power line connected to this product must be less than 10m if used as a CE marked product. Stop machinery and equipment, and check safe- ty before setting switch output. Operate the key with a fi ngertip. Knife, screwdriver and other hard tip tods or objects may damage the plastic fi lm over the control. Piping Apply seal tape or sealant to screw-in joint, then screw the joint into the port to avoid excessive torque. Apply a spanner on the metal section to tighten. When winding seal tape, wind the tape leaving 2mm and over open from the thread top. If seal tape extrudes from the thread top, seal tape chips could be created when screwed in. These chips could enter into the circuit, and cause mal- function. Use pipe 1m long, and do not apply tension and impact to the pipe. If longer pipe is used, tension not expected could be created by the pipe weight, vibration or impact. In this case, use an intermediate support to fi x the pipe on the ma- chine or equipment. Do not connect relays, switches or other devic- es to the output of this sensor in parallel at the PLC. Do not short-circuit the PLC input terminal connected to this sensor and (-) side of power to test input devices, neither, or the output circuit of this unit could be damaged. Intro 5 Cable with connector (PPX-C*) Jaw Contact: SPHD-001T-P0.5 Housing: PAP-04V-S [JST MFG CO. LTD.] Solid/ liquid sealant Solid/ liquid sealant PPXSeries During Use & Maintenance When unit is changed If the product for domestic market is used with unit change function, and if unit other than MPa and kPa is used, put the unit label enclosed with the product on the unit display sec- tion in the control. PPX bar Putting seal label kPa MPa kgf/cm3 bar psi mmHg inHg Pressure unit label WARNING Do not apply overcurrent. Due to short-circuit of load, if overcurrent applies to the pres- sure switch, the switch could be damaged or ignite. Install a fuse on output or power line as a overcurrent protective circuit. CAUTION Do not disassemble the product. Disassembling the product could result in damage or deterio- ration of the product. CKD will not guarantee the performance after disassembling. When replacing or moving the product, remove the sensor without disassembling pressurized port. Stop machinery and equipment, then check the safety before operating the product. The case is made of resin. Do not use solvent, alcohol or any other cleaning agent, etc., to remove contamination, etc., or resin could be corroded or damaged. Wipe contaminations with a well wrung rag, etc., after soaked in weakened neutral detergent. Care must be taken for disconnection and reverse current caused by wiring resistance. When components including pressure switches are connected to the same power source of pressure switch, if (-) sides of output and power lines are short-circuited to check input devices of the control panel, or if (-) side of power line is disconnected, reverse current may ap- ply to the output circuit of pressure switch, causing damages. Take countermeasures as followings to prevent damages caused by reverse current. Do n
本文档为【CKD 真空开关】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_115100
暂无简介~
格式:pdf
大小:2MB
软件:PDF阅读器
页数:32
分类:生产制造
上传时间:2012-06-12
浏览量:34