首页 德国E+H温度仪表:温度变送器 iTEMP HART TMT122

德国E+H温度仪表:温度变送器 iTEMP HART TMT122

举报
开通vip

德国E+H温度仪表:温度变送器 iTEMP HART TMT122 TI090R/09/en 51003953 Temperature transmitter iTEMP® HART® DIN rail TMT122 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage transmitters, incorporating HART® protocol Application areas • Tempera...

德国E+H温度仪表:温度变送器 iTEMP HART TMT122
TI090R/09/en 51003953 Temperature transmitter iTEMP® HART® DIN rail TMT122 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage transmitters, incorporating HART® protocol Application areas • Temperature transmitter with HART® protocol for converting various input signals into a scalable 4 to 20 mA analogue output signal • Input: Resistance thermometer (RTD) Thermocouple (TC) Resistance transmitter (Ω) Voltage transmitter (mV) • HART® protocol for front end unit or panel unit operation using the hand operating module (DXR275, DXR375) or PC (e.g. ReadWin® 2000 or FieldCare) • Installation on DIN rail according to IEC 60715 Features and benefits • Universal settings with HART® protocol for various input signals • 2-wire technology, 4 to 20 mA analogue output • High accuracy in total ambient temperature range • Fault signal on sensor break or short circuit, presettable to NAMUR NE 43 • EMC to NAMUR NE 21, CE • UL recognized component to UL 3111-1 • Ex-Certification: - ATEX Ex ia - CSA IS - FM IS • Ship building approval GL • Galvanic isolation • Output simulation • Min./max. process value indicator function • Customer-specific linearisation • Linearisation curve match • Customer-specific measurement range settings or expanded SETUP (see Questionnaire, page 7) 0 2 1 â Ó TMT122 2 Endress+Hauser Operation and system construction Measurement principle Electronic measurement and conversion of input signals in industrial temperature measurement. Measurement system The iTEMP® HART® DIN rail TMT122 temperature transmitter is a 2-wire transmitter with an analogue output. It has measurement input for resistance thermometers (RTD) in 2-, 3- or 4-wire connection, thermo- couples and voltage transmitters. Setting up of the TMT122 is done using the HART® protocol with hand operating module (DXR275, DXR375) or PC (e.g. configuration software ReadWin® 2000 or FieldCare). Input Measured variable Temperature (temperature linear), resistance and voltage. Measuring range Depending upon the sensor connection and input signal. The transmitter evaluates a number of different meas- urement ranges. Type of input Resistance thermometer (RTD) Type Measurement ranges Min. measurement range Pt100 Pt500 Pt1000 acc. to IEC 751 (α = 0.00835) Pt100 acc. to JIS C 1604-81 (α = 0.003916) -200 to 850 °C (-328 to 1562 °F) -200 to 250 °C (-328 to 482 °F) -200 to 250 °C (-238 to 482 °F) -200 to 649 °C (-328 to1200 °F) 10 K 10 K 10 K 10 K Ni100 Ni500 Ni1000 acc. to DIN 43760 (α = 0.006180) -60 to 250 °C (-76 to 482 °F) -60 to 150 °C (-76 to 302 °F) -60 to 150 °C (-76 to 302 °F) 10 K 10 K 10 K • Connection type: 2-, 3- or 4-wire connection • Software compensation of cable resistance possible in the 2-wire system (0 to 30 Ω) • Sensor cable resistance max. 40 Ω per cable • Sensor current: ≤ 0.2 mA Resistance transmitter Resistance Ω 10 to 400 Ω 10 to 2000 Ω 10 Ω 100 Ω Thermocouples (TC) B (PtRh30-PtRh6) C (W5Re-W26Re)a D (W3Re-W25Re)a E (NiCr-CuNi) J (Fe-CuNi) K (NiCr-Ni) L (Fe-CuNi)b N (NiCrSi-NiSi) R (PtRh13-Pt) S (PtRh10-Pt) T (Cu-CuNi) U (Cu-CuNi)b 0 to +1820 °C (32 to 3308 °F) 0 to +2320 °C (32 to 4208 °F) 0 to +2495 °C (32 to 4523 °F) -270 to +1000 °C (-454 to 1832 °F) -210 to +1200 °C (-346 to 2192 °F) -270 to +1372 °C (-454 to 2501 °F) -200 to +900 °C (-328 to 1652 °F) -270 to +1300 °C (-454 to 2372 °F) -50 to +1768 °C (-58 to 3214 °F) -50 to +1768 °C (-58 to 3214 °F) -270 to +400 °C (-454 to 752 °F) -200 to +600 °C (-328 to 1112 °F) 500 K 500 K 500 K 50 K 50 K 50 K 50 K 50 K 500 K 500 K 50 K 50 K • Cold junction internal (Pt100) • Cold junction accuracy: ± 1 K Voltage transmitters Millivolt transmitter -10 to 75 mV 5 mV a. According to ASTM E988 b. According to DIN IEC 584 part 1 TMT122 Endress+Hauser 3 Output Output signal Analogue 4 to 20 mA, 20 to 4 mA Signal on alarm • Measurement range undercut: Linear drop to 3.8 mA • Exceeding measurement range: Linear rise to 20.5 mA • Sensor breakage; Sensor short circuit1: ≤ 3.6 mA or ≥ 21.0 mA (if setting ≥ 21.0 mA the output is > 21.5 mA) Load Max. (VPower supply - 12 V) / 0.022 A (Current output) Linearisation / transmission behaviour Temperature linear, resistance linear, voltage linear Filter Digital filter 1. degree: 0 to 100 s Galvanic isolation U = 2 kV AC (Input/output) min. current consumption ≤ 3.5 mA Current limit ≤ 23 mA Switch on delay 4 s (during power up Ia ≈ 3.8 mA) Auxiliary energy Electrical connection Temperature transmitter terminal connections For the unit operation via HART® communication sockets a minimum load resistance of 250 Ω is necessary in the signal circuit! Power supply Ub = 12 to 35 V, polarity protected Residual ripple Allowable ripple Uss ≤ 3 V at Ub ≥ 15 V, f max. = 1 kHz 1. Not for thermocouple T0 9- TM T1 22 -0 4- 10 -X X- en -0 01 .e ps TMT122 4 Endress+Hauser Performance characteristics Response time 1 s Reference operating conditions Calibration temperature: +23 °C ± 5 K (73.4 °F ± 9 °F) Maximum measured error Influence of power supply ≤ ± 0.01%/V deviation from 24 V1 Influence of ambient temperature (temperature drift) • Resistance thermometer (RTD): Td = ± (15 ppm/K * max. meas. range + 50 ppm/K * preset meas. range) * ∆ ϑ • Resistance thermometer Pt100: Td = ± (15 ppm/K * (range end value + 200) + 50 ppm/K * preset meas. range) * ∆ ϑ • Thermocouple (TC): Td = ± (50 ppm/K * max. meas. range + 50 ppm/K * preset meas. range) * ∆ ϑ ∆ ϑ = Deviation of the ambient temperature according to the reference condition (+23 °C ± 5 K or 73.4 °F ± 9 °F). Long term stability ≤ 0.1K/Year2 or ≤ 0.05%/Year2 3 Influence of load ≤ ±0.02%/100 Ω1 Influence of cold junction Pt100 DIN IEC 751 Cl. B (internal reference junction for thermocouples TC) Installation conditions Installation instructions Orientation No limit Type Measurement accuracy3 Resistance thermometer RTD Pt100, Ni100 Pt500, Ni500 Pt1000, Ni1000 0.2 K (0.36 °F) or 0.08% 0.5 K (0.9 °F) or 0.20% 0.3 K (0.54 °F) or 0.12% Thermocouple TC K, J, T, E, L, U N, C, D S, B, R typ. 0.5 K (0.9 °F) or 0.08% typ. 1.0 K (1.8 °F) or 0.08% typ. 2.0 K (3.6 °F) or 0.08% Measurement range Measurement accuracy3 Resistance transmitter (Ω) 10 to 400 Ω 10 to 2000 Ω ± 0.1 Ω or 0.08% ± 1.5 Ω or 0.12% Voltage transmitter (mV) -10 to 75 mV ± 20 µV or 0.08% 1. All data is related to a measurement end value 2. According to reference conditions 3. % is related to the adjusted measurement range (the value to be applied is the greater one). TMT122 Endress+Hauser 5 Environment conditions Ambient temperature range Preferably reference conditions Ambient temperature limits −40 to +85 °C (-40 to +185 °F) for Ex-area, see Ex-certification Storage temperature -40 to +100 °C (-40 to +212 °F) Climate class According to EN 60 654-1 (IEC 60654-1), Class C Ingress protection IP 20 Electromagnetic compatibility (EMC) Interference immunity and interference emission according to EN 61 326-1 (IEC 1326) and NAMUR NE 21 Condensation Permitted Shock and vibration resistance 4g / 2 to 150 Hz as per IEC 60 068-2-6 Mechanical construction Design, dimensions Housing for DIN rail mounting according to IEC 60715; Dimensions in mm (inches) Weight Approx. 90 g (3.2 oz) Material Housing: Plastic PC/ABS, UL 94V0 Terminals Keyed plug-in screw terminals, core size max. 2.5 mm² (16 AWG) solid, or strands with ferrules T0 9- TM T1 22 -0 6- 10 -X X- en -0 02 .e ps TMT122 8 Endress+Hauser Product structure Accessories Commubox FXA191, PC operating software ReadWin® 2000 or FieldCare Certification A Version for non Ex areas B ATEX II 2(1) G EEx ia IIC T4/T5/T6 C FM IS, Class I, Div. 1+2, Group A, B, C, D D CSA IS, Class I, Div. 1+2, Group A, B, C, D E ATEX II3G EEx nA IIC T4/T5/T6 I FM+CSA IS, NI, Class I, Div. 1+2, Group A, B, C, D J CSA General Purpose Configuration transmitter connection A Standard factory configuration 1 Configuration connection TC 2 Configuration connection RTD 2-wire 3 Configuration connection RTD 3-wire 4 Configuration connection RTD 4-wire Configuration temperature sensor A Standard factory configuration B Config. Typ B (0 to 1820 °C min. span 500 K) C Config. Typ C (0 to 2320 °C min. span 500 K) D Config. Typ D (0 to 2495 °C min. span 500 K) E Config. Typ E (-200 to 1000 °C min. span 50 K) J Config. Typ J (-200 to 1200 °C min. span 50 K) K Config. Typ K (-200 to 1372 °C min. span 50 K) L Config. Typ L (-200 to 900 °C min. span 50 K) N Config. Typ N (-270 to 1300 °C min. span 50 K) R Config. Typ R (-0 to 1768 °C min. span 500 K) S Config. Typ S (-0 to 1768°C min. span 500 K) T Config. Typ T (-200 to 400 °C min. span 50 K) U Config. Typ U (-200 to 600 °C min. span 50 K) 1 Config. Pt100 acc. to IEC751 (-200 to 850 °C min. span 10 K) 2 Config. Ni100 (-60 to 180 °C min. span 10 K) 3 Config. Pt500 (-200 to 250 °C min. span 10 K) 4 Config. Ni500 (-60 to 150 °C min. span 10 K) 5 Config. Pt1000 (-200 to 250 °C min. span 10 K) 6 Config. Ni100 (-60 to 150 °C min. span 10 K) 9 Config. Pt100 acc. to JIS C1604-81 (-200 to 649 °C min. span 10 K) Setup A Standard factory configuration (Pt100/3-wire/0 to 100 °C) B Customised measurement range C Customised expanded configuration for TC (see questionnaire) D Customised expanded configuration for RTD (see questionnaire) Model A Standard model B Works calibration certificate 6 test points TMT122- ⇐ Order code iTEMP HART TMT122 1 iTEMP HART TMT122 2 iTEMP HART TMT122 3 iTEMP HART TMT122 4 iTEMP HART TMT122 5 iTEMP HART TMT122 6 iTEMP HART TMT122 7
本文档为【德国E+H温度仪表:温度变送器 iTEMP HART TMT122】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_864384
暂无简介~
格式:pdf
大小:463KB
软件:PDF阅读器
页数:0
分类:生产制造
上传时间:2012-03-03
浏览量:45