USP1231Water_Criteria Page 3 of 41 1.3 USP Purified Water and Water for Injection Criteria The criteria presented below are condensed and / or excerpted from sections 643 and 645 of the United States Pharmacopoeia (USP), 25th edition. 1.3.1 Selected Criteria Parameter ...

USP1231Water_Criteria
Page 3 of 41 1.3 USP Purified Water and Water for Injection Criteria The criteria presented below are condensed and / or excerpted from sections 643 and 645 of the United States Pharmacopoeia (USP), 25th edition. 1.3.1 Selected Criteria Parameter PW WFI pH 5.0 - 7.0 5.0 – 7.0 TOC < 500 ppb < 500 ppb Total Bacteria Count ≤ 10 colony forming unit (cfu)/ml, pathogen free ≤ 10 cfu/ 100 ml, pathogen free Endotoxin Not Specified ≤ 0.25 EU/ml Feed Water Potable Water Not Specified, but Health Canada regulations demand that PW be used 1.3.2 Conductivity / Resistivity Stage 1 Procedure and Criteria: Conductivity criteria for PW and WFI are the same. The conductivity criteria measured in-line, uncompensated for temperature, are listed below and are referred to as Stage 1 Criteria. If the Stage 1 Criteria are not met, a Stage 2 should be conducted, and then if necessary (Stage 2 failure) a Stage 3 test may be conducted. Temperature (°C) Conductivity (µS/cm) Resistivity (MΩ-cm) Temperature (°C) Conductivity (µS/cm) Resistivity (MΩ-cm) 0 0.6 1.67 45 1.8 0.56 5 0.8 1.25 50 1.9 0.53 10 0.9 1.11 55 2.1 0.48 15 1.0 1.00 60 2.2 0.45 20 1.1 0.91 65 2.4 0.42 25 1.3 0.77 70 2.5 0.40 30 1.4 0.71 75-90 2.7 0.37 35 1.5 0.67 95 2.9 0.34 40 1.7 0.59 100 3.1 0.32 Note that the USP defines the quality in terms of conductivity. Page 4 of 41 Stage 2 Procedure and Criteria: Take a 100 ml (or more) sample, and vigorously stir in an open beaker maintaining the temperature at 25±1°C. Periodically observe the conductivity. When the change in conductivity (due to uptake of atmospheric CO2) is less than a net of 0.1 µS/cm per 5 minutes, note the conductivity. If the conductivity is not greater than 2.1 µS/cm the water meets the requirements of the test for conductivity. If the conductivity is greater, proceed to Stage 3. Stage 3 Procedure and Criteria: This test is to be carried out within 5 minutes of the Stage 2 test on the same sample, while continuing to maintain the sample temperature at 25±1°C. Add 0.3 ml of saturated potassium chloride solution per 100 ml of sample to the sample and determine the pH to the nearest 0.1 pH unit as directed under USP section 791. If the pH is outside the range of 5.0 - 7.0 or if the end point conductivity measured in Stage 2 is greater than the conductivity criteria summarized in the table below, the water does not meet the criteria of the test for conductivity. Stage 3 pH Stage 2 Conductivity Limit (µS/cm) Stage 3 pH Stage 2 Conductivity Limit (µS/cm) 5.0 4.7 6.1 2.4 5.1 4.1 6.2 2.4 5.2 3.6 6.3 2.4 5.3 3.3 6.4 2.3 5.4 3.0 6.5 2.2 5.5 2.8 6.6 2.1 5.6 2.6 6.7 2.6 5.7 2.5 6.8 3.1 5.8 2.4 6.9 3.8 5.9 2.4 7.0 4.6 6.0 2.4
本文档为【USP1231Water_Criteria】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_466477
暂无简介~
格式:pdf
大小:84KB
软件:PDF阅读器
页数:2
分类:
上传时间:2012-02-27
浏览量:22