首页 NBR 14136:巴西插头插座尺寸

NBR 14136:巴西插头插座尺寸

举报
开通vip

NBR 14136:巴西插头插座尺寸 NOVEMBER 2002 NBR 14136 ABNT - Brazilian Association of Technical Standards Main office: Rio de Janeiro Av. Treze de Maio, 13 – 28th floor ZIP CODE 20003-900 – P.0.box 1680 Rio de Janeiro - RJ Tel.: (21) 3974-2300 Fax: (21) 2240-8249/2220-6436 Web: www.abnt...

NBR 14136:巴西插头插座尺寸
NOVEMBER 2002 NBR 14136 ABNT - Brazilian Association of Technical Standards Main office: Rio de Janeiro Av. Treze de Maio, 13 – 28th floor ZIP CODE 20003-900 – P.0.box 1680 Rio de Janeiro - RJ Tel.: (21) 3974-2300 Fax: (21) 2240-8249/2220-6436 Web: www.abnt.org.br Copyright © 2002, ABNT – Associação Brasileira de Normas Técnicas Printed in Brazil All rights reserved Plugs and socket-outlets for household and similar purposes up to 20 A/250 Va.c. - Standardization Origin: Project NBR 14136:2001 ABNT/CB-03 - Brazilian Committee of Electricity CE-03:023.02 - Study Commission for Switches, Socket-outlets, Pins and Plates for General Use NBR 14136 - Plugs and socket-outlets for household and similar purposes Standardization Descriptors: Plug. Socket-outlet This Standard has been based on IEC 60906-1:1986 This Standard cancels and replaces NBR 14136:1998 Valid from December 29, 2002 on Key-words: Plug. Socket-outlet 20 pages Summary Foreword 1 Objective 2 Normative references 3 Requirements ANNEX A Figures Foreword ABNT – The Brazilian Association of Technical Standards - is the National Committee of Standardization. The Brazilian standards, which content is responsibility of Brazilian Committees (ABNT/CB) and the Organizations of Sectorial Standardization (ABNT/ONS), are elaborated by Study Commissions (CE), composed by representatives of the involved sections, like: producers, consumers and neutral (universities, laboratories and other). The drafts of Brazilian standards, elaborated in the extent of ABNT/CB and ABNT/ONS, are circulated for Public Consultation among ABNT associates and interested parties. This Standard contains the annex A, it is normative. 1 Scope 1.1 This Standard sets the dimensions for plugs and socket-outlets with nominal characteristics up to 20 A/250 V a.c., intended for household and similar purposes, to be used in the connection to distribution systems with nominal tensions rated between 100 V and 250 V a.c. 1.2 This Standard is applied to the plugs and socket-outlets specified in NBR 6147. 1.3 This Standard is not applied to the plugs and socket-outlets designed to the class 0 equipments. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this Standard. The indicated issues were in force when this Standard was published. As every Standard might suffer revisions, it is recommended to those that accomplish agreements based on this document to verify the convenience of using the most recent issue of the mentioned Standards. ABNT maintains registers of currently valid editions. NBR 6147:2000 - Plugs and socket-outlets for household and similar purposes - Specification NBR 11467:1991 - graphic Symbols for use in equipments - Symbols 3 Requirements 3.1 Dimensions The plugs and socket-outlets shall be in agreement with the dimensions of the appropriate figures of annex A. 3.2 Compatibility The 20 A socket-outlets shall admit the insertion of 10 A and 20 A plugs, and the socket-outlets with earthing-contact shall admit the insertion of plugs with and without earthing-pin. The 10 A socket-outlets shall not admit the insertion of 20 A plugs. / ANNEX A 2 NBR14136:2002 Annex A (normative) Figures Dimensions in millimeters NOTES 1 See explanatory notes on page 9. 2 These figures are not intended to govern the plan, except in the shown dimensions. 3 Several constructions can be used, such as multiple socket-outlets. Figure 1 – Socket-outlet to built-in, two-pole, with earthing contact - 10 A/250 Vc.a. NBR14136:2002 3 Sharp edges slightly rounded Detail of the entrance holes Protecting surface Dimensions in millimeters NOTES 1 See explanatory notes on page 9. 2 These figures are not intended to govern the plan, except in the shown dimensions. 3 Several constructions can be used, such as multiple socket-outlets. Figure 2 – Socket-outlet to built-in, two-pole, with earthing contact - 20 A/250 Vc.a. 4 NBR14136:2002 Protecting surface Sharp edges slightly rounded Detail of the entrance holes Dimensions in millimeters NOTES 1 See explanatory notes on page 9. 2 For the dimensions that were not indicated see figure 1. 3 These figures are not intended to govern the plan, except in the shown dimensions. 4 Several constructions can be used, such as multiple socket-outlets. Figure 3 - Socket-outlet to semi-built-in or to put upon, two-pole, with earthing-contact - 10 A/250 Vc.a. NBR14136:2002 5 Protecting surface With protecting surface Without protecting surface 6 NBR14136:2002 Dimensions in millimeters NOTES 1 See explanatory notes on page 9. 2 For the dimensions that were not indicated see figure 2. 3 These figures are not intended to govern the plan, except in the shown dimensions. 4 Several constructions can be used, such as multiple socket-outlets. Figure 4 – Socket-outlet to semi-built-in or to put upon, two-pole, with earthing-contact - 20 A/250 Vc.a. Protecting surface With protecting surface Without protecting surface NBR14136:2002 7 Dimensions in millimeters NOTES 1 See explanatory notes on page 9. 2 For the dimensions that were not indicated see figure 1. 3 These figures are not intended to govern the plan, except in the shown dimensions. 4 Several constructions can be used, such as multiple socket-outlets. Figure 5 – Portable socket-outlet, two-pole, with earthing contact. - 10 A/250 Vc.a. Protecting surface With protecting surface Without protecting surface With recess With collar 8 NBR14136:2002 Dimensions in millimeters NOTES 1 See explanatory notes on page 9. 2 For the dimensions that were not indicated see figure 2. 3 These figures are not intended to govern the plan, except in the shown dimensions. 4 Several constructions can be used, such as multiple socket-outlets. Figure 6 – Portable socket-outlet, two-pole, with earthing contact. - 20 A/250 Vc.a. Protecting surface With protecting surface Without protecting surface With recess With collar NBR14136:2002 9 Explanatory notes for figures 1, 2, 3, 4, 5 and 6 Î A recess shall be provided for socket-outlets to built-in, a collar for those to put upon or for portable types, or a combination of both for the semi-built-in type. For the semi-built-in socket-outlets, the impossibility of single-pole insertion shall be verified. Ï If those dimensions were not respected, a gauge shall be used for verifying the impossibility of single-pole insertion. Regarding the use of shutters as the only way to prevent single-pole insertion, see NBR 6147. Ð This dimension has been provided for the plate, the guide of the plug pins and for the eventual shutter mechanism. The shutters are optional. It is not necessary to supply a proper space to the shutters in those models without this device. Ñ In the limits of that thickness, the guide for the plug pins shall have at least 1,5 mm with the specified diameter. Ò Small chamfer or radius. Ó The points that first touch the alive contacts and the earthing-contact shall be verified. Ô This dimension is verified using a gauge in the most unfavorable conditions. Õ The contacts shall be elastic. Their shape might be different from the tubular. An entrance in an appropriate way, with a chamfer or a radius, is necessary to prevent damage of the contact when the plug is inserted in the most unfavorable angle. Its convenience is verified by performing all the tests specified in NBR 6147. Ö The earthing-terminal shall be identified with the symbol (3.2.19 of NBR 11467:1991). The identification of the other terminals is optional. The marking shall be put close to the terminals. It is not necessary to mark the terminals in those models that cannot by disassembled. Dimensions in millimeters NOTES 1 See explanatory notes on page 12. 2 These figures are not intended to govern the plan, except in the shown dimensions. 3 The plugs can, or cannot, be disassembled. Figure 7 – Two-pole Plug, with earthing-pin (for class I appliances) up to 10 A/250 Vc.a. 10 NBR14136:2002 Engagement face Earthing-pin and optional construction for the pin that carries current (alive) No sharp edges NBR14136:2002 11 Dimensions in millimeters NOTES 1 See explanatory notes on page 12. 2 These figures are not intended to govern the plan, except in the shown dimensions. 3 The plugs can, or cannot, be disassembled. Figure 8 – Two-pole Plug, with earthing-pin (for class I appliances) above 10 A up to 20 A/250 Vc.a. Engagement face Earthing-pin and optional construction for the pin that carries current (alive) No sharp edges 12 NBR14136:2002 Explanatory notes for figures 7 and 8 Î The earthing-terminal shall be identified with the symbol (3.2.19 of NBR 11467:1991). The identification of the other terminals is optional. The marking shall be made inside the body, close to the terminals. It is not necessary to mark the terminals in those models that cannot be disassembled. Ï The distance between the engagement face and the cord or the exit for the cable or the eventual cord protection shall be of 14 mm, at least. The conformity is verified by measurement. Ð In the limits of this dimension, the outline shall not be smaller than the outline of the engagement face. Ñ In the limits of this dimension, the outline should not be larger than outline of the engagement face. Ò The insulating sleeves of the alive pins are optional. If the insulating sleeves are separated parts, they shall penetrate in the body of the plug in, at least, 3 mm measured from the engagement face. Ó The external diameter of the insulating sleeves shall not overcome the uncovered part of the pins. Ô To avoid the shutters damage, the extremities of the pins shall not present sharp edges or burrs; they shall be rounded, as shown. Õ The angle of 90º sets the maximum area which the flexible cord entrance shall be allowed. NBR14136:2002 13 Dimensions in millimeters NOTES 1 See explanatory notes on page 17. 2 The socket-outlets can, or cannot, be disassembled. 3 These figures are not intended to govern the plan, except in the shown dimensions. 4 Several constructions can be used, such as multiple socket-outlets. Figure 9 – Portable two-pole socket-outlet without earthing-contact - 10 A/250 Vc.a. Detail of the entrance holes 14 NBR14136:2002 Dimensions in millimeters NOTES 1 See explanatory notes on page 17. 2 The socket-outlets can, or cannot, be disassembled. 3 These figures are not intended to govern the plan, except in the shown dimensions. 4 Several constructions can be used, such as multiple socket-outlets. Figure 10 - Portable two-pole socket-outlet without earthing-contact - 20 A/250 Vc.a. Detail of the entrance holes NBR14136:2002 15 Dimensions in millimeters NOTES 1 See explanatory notes on page 17. 2 The socket-outlets can, or cannot, be disassembled. 3 These figures are not intended to govern the plan, except in the shown dimensions. 4 Several constructions can be used, such as multiple socket-outlets. Figure 11 - Portable two-pole socket-outlet without earthing-contact with protecting surface - 10 A/250 Vc.a. Protecting surface With recess With collar 16 NBR14136:2002 Dimensions in millimeters NOTES 1 See explanatory notes on page 17. 2 For the dimensions that were not indicated, see Figure 10. 3 These figures are not intended to govern the plan, except in the shown dimensions. 4 Several constructions can be used, such as multiple socket-outlets. Figure 12 - Portable two-pole socket-outlet without earthing-contact with protecting surface - 20 A/250 Vc.a. Protecting surface With recess With collar NBR14136:2002 17 Explanatory notes for figures 9, 10, 11 and 12. These Figures are equally provided for socket-outlets which are incorporated in appliances. Î A collar shall be provided for the models without protecting surface or a recess, or a combination of a collar and a recess for the socket-outlets with protecting surface. In cases of such combination the impossibility of single-pole insertion shall be verified. Ï If those dimensions were not respected, a gauge shall be used for verifying the impossibility of single-pole insertion. Regarding the use of shutters as the only way to prevent single-pole insertion, see NBR 6147. Ð This dimension has been provided for the plate, the guide of the plug pins and for the eventual shutter mechanism. These shutters are optional. It is not necessary to supply a proper space to the shutters in those models without this device. Ñ In the limits of that thickness, the guide for the plug pins shall have at least 1,5 mm with the specified diameter. Ò Small chamfer or radius. Ó The points that first contact shall be verified with a gauge. Ô The contacts shall be elastic. Their shape might be different from the tubular. An entrance in an appropriate way, with a chamfer or a radius, is necessary to prevent the damage of the contact when the plug is inserted in the most unfavorable angle. Its convenience is verified by performing all the tests specified in NBR 6147. 18 NBR14136:2002 Dimensions in millimeters NOTES 1 See explanatory notes on page 20. 2 These figures are not intended to govern the plan, except in the shown dimensions. 3 This plug can, or cannot, be disassembled. Figure 13 - Two-pole Plug without earthing-pin (for class II appliances) up to 10 A/250 V a.c. Engagement face Optional construction without insulating sleeves NBR14136:2002 19 Dimensions in millimeters NOTES 1 See explanatory notes on page 20. 2 These figures are not intended to govern the plan, except in the shown dimensions. 3 This plug can, or cannot, be disassembled. Figure 14 - Two-pole Plug without earthing-pin (for class II appliances) above 10 A up to 20 A/250 Vc.a. Engagement face Optional construction without insulating sleeves 20 NBR14136:2002 Explanatory notes for figures 13 and 14 Î The distance between the engagement face and the cord or the exit for the cord or the eventual protection of the cord shall be 14 mm, at least. The conformity is verified by measurement. ÏIn the limits of this dimension, the outline shall not be smaller than the outline of the engagement face. Ð In the limits of that dimension, the outline shall not be larger than the outline of the engagement face. Ñ The insulating sleeves of the alive pins are optional. If the insulating sleeves are separated parts, they shall penetrate in the body of the plug in, at least, 3 mm measured from the engagement face. Ò The external diameter of the insulating sleeves shall not overcome the uncovered part of the pins. Ó To avoid the shutters damage, the extremities of the pins shall not present sharp edges or burrs; they shall be rounded, as shown. ÔThe angle of 90º sets the maximum area which the flexible cord entrance shall be allowed.
本文档为【NBR 14136:巴西插头插座尺寸】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_857834
暂无简介~
格式:pdf
大小:411KB
软件:PDF阅读器
页数:20
分类:生产制造
上传时间:2012-01-31
浏览量:108