下载

1下载券

加入VIP
  • 专属下载特权
  • 现金文档折扣购买
  • VIP免费专区
  • 千万文档免费下载

上传资料

关闭

关闭

关闭

封号提示

内容

首页 SYT 5922-2003天然气管道运行规范

SYT 5922-2003天然气管道运行规范.pdf

SYT 5922-2003天然气管道运行规范

wuhanhua
2012-01-06 0人阅读 举报 0 0 暂无简介

简介:本文档为《SYT 5922-2003天然气管道运行规范pdf》,可适用于经济金融领域

ICS一E备案号:中华人民共和国石油天然气行业标准SY'代替SY',SYI',SYI',SY'天然气管道运行规范Runcriterionofnaturalgaspipeline一一发布一一实施国家经济贸易委员会发布wwwegascnSY`C目次前言···················································································································一II范围········································。················································⋯⋯规范性引用文件···························································································⋯⋯术语和定义··⋯⋯总则···············································································。······························⋯⋯气质要求·········································································································⋯⋯工程预验收·······································································‘········‘·············二试运投产······································································································⋯⋯运行管理·······附录A(资料性附录)管道干燥方法············。······································。···‘····。······⋯⋯附录B(规范性附录)管道运行工艺计算···············。·····································。············⋯⋯附录C(规范性附录)管道试压工艺计算·wwwegascnSY'T前言本标准是对SYI'(天然气输送管道运行管理规范》、SYT心天然气运行管线试压技术规范》、SYI'《天然气管道试运投产规范》和SYI'《长输天然气管道清管作业规程》的修订。本标准与SYI',SYr,SYI'和SY'相比除了将四项标准整合成一项标准外还将已不能满足现实需要的原有标准部分内容作了修订对部分标准之间相互冲突的相关内容做了一致性修改。本标准的附录A为资料性附录附录B和附录C为规范性附录。本标准由油气储运专业标准化技术委员会提出并归口。本标准起草单位:中国石油天然气股份有限公司管道分公司、西南油气田分公司、北京华油天然气有限公司。本标准主要起草人:张城、路小峰、舒昌成、张增强、廖强、张湘平、张鹏。本标准所代替标准的历次版本发布情况为:SY'SYI'SYI',SYI'SYI',wwwegascnSY'f天然气管道运行规范范围本标准规定了输送净化天然气的管道的投产验收、试运投产、运行管理和维护方面的技术要求和规定。本标准适用于输送经净化后的天然气的管道。规范性引用文件下列文件中的条款通过本标准的引用而成为本标准的条款。凡是注日期的引用文件其随后所有的修改单(不包括勘误的内容)或修订版均不适用于本标准然而鼓励根据本标准达成协议的各方研究是否可使用这些文件的最新版本。凡是不注日期的引用文件其最新版本适用于本标准。GBT天然气中硫化氢含量的测定碘量法GBC天然气中总硫量的测定、氧化微库仑法GBC天然气发热量、密度、相对密度和沃泊指数的计算方法GBC天然气取样导则GBC天然气的组成分析气相色谱法GBC天然气水露点的测定冷却镜面凝析湿度计法GB输气管道工程设计规范SYC油气田地面管线和设备涂色标准SYC埋地钢质管道外壁涂敷有机覆盖层技术规定SY输油输气管道线路工程施工及验收规范SY石油天然气站内工艺管道工程施工及验收规范SYNC埋地钢质管道石油沥青防腐层技术标准SY石油天然气管道跨越工程施工及验收规范SYJ长输管道阴极保护工程施工及验收规范SYJ油气田集输工艺管道动火安全技术规程SYNC石油天然气管道穿越工程施工及验收规范SYNC埋地钢质管道沥青防腐层大修理技术规定SY'天然气输送企业计量器具配备规范SYNC油气管道架空部分及其附属设施维护保养规程SYNC天然气流量的标准孔板计量方法SYNC输油输气管道仪表及自动化设施管理规定SYNC输油输气管道电气设备技术管理规定SYNC输油气管道通用阀门操作、维护、检修规程石油天然气管道保护条例国务院第号令年月日发布术语和定义下列术语和定义适用于本标准。wwwegascnSYFf水露点waterdewpoint气体在一定压力下析出第一滴水时的温度。烃露点hydrocarbondewpoint气体在一定压力下析出第一滴液态烃时的温度。压缩因子compressionfactor在规定的压力和温度下任意质量气体的体积与该气体在相同条件下按理想气体定律计算的气体体积的比值:Z=Vm(真实)V彩理想)········⋯⋯Vm(理想)=RTPZ(P,T,妇二PV(真实)ART)式中:P绝对压力T热力学温度Y表征气体的一组参数(原则上Y可以是摩尔全组成或是一组特征的相关物化性质或者是两者的结合)Vm一气体的摩尔体积R摩尔气体常数与单位无关压缩因子。输气站gastransmissionstation输气管道起讫点及沿线按输送工艺需要而设立的站场。一般包括首站、末站、中间清管站、压气站、分输站及配气站等。压气站。impressorstation在输气管道沿线用压缩机对管道天然气增压的站。喘振surging是离心式压缩机特有的一种现象。任何结构尺寸的离心式压缩机在某一转速下都有一个流量的低限和压比的高限。低于流量低限和超过压比高限时机组开始激烈振动并伴有异常吼叫声。过盈量surplusquantum清管球(器)外径大于管道内径的值与管道内径的百分比。SCADA系统supervisorycontrolanddataacquisitionsystem监控与数据采集系统无论规模大小都由三部分组成:位于调度控制中心的主端调度装置(MTL)、位于各站场的远程终端装置(RTU)和连接它们的通信系统。使用SCADA系统可对指定设施提供连续监测并从控制中心对这些设施进行操作控制。wwwegascnSY汀地下储气库undergroundgasstorage利用天然地质构造(如枯竭的油气田、含水层和盐层等)将天然气以气态形式储存的设施。总则输气管道每年宜有dd的检修期。管道吹扫、试压、干燥、置换、投产、清管、管道干线内(外)壁检测等生产活动应编制详细的方案方案内容应包含:a)生产活动组织机构、职责、协议等b)管道历史情况记录和现状c)详细的操作(运行)程序和步骤d)安全、环保措施e)事故预案。管道各项生产活动应记录、分析整理后存档。管道的各项生产活动都应符合国家和地方安全、环境保护法规的要求。气质要求气质指标管输天然气气质指标见表to表管输天然气气质指标项目质量指标高位发热量v>总硫(以硫计)mgmG硫化氢mgm二氧化碳(体积分数)<氧气(体积分数)成水露点℃在最高操作压力下水露点应比最低输送环境温度低℃烃露点℃在最高操作压力下烃露点应不大于最低输送环境温度注:本标准中气体体积的标准参比条件是kPa,C。天然气中固体颗粒含量应不影响天然气的输送和利用固体颗粒的直径应小于mma试验方法和检测规则进气点(包括地下储气库中所储天然气进人管道的人口)应配有微水分析仪、硫化氢和二氧化碳分析仪进行监测。天然气高位发热量、压缩因子、气质组分分析应每季度一次高位发热量的计算应按GBT执行其所依据的天然气组成的测定应按GB'执行。天然气中总硫含量的测定应按GBT执行。天然气硫化氢的测定应每月一次硫化氢含量的测定及仲裁应按GBT执行。天然气二氧化碳的测定应每月一次二氧化碳含量的测定应按GBT执行。wwwegascnSY'天然气中氧含量的测定应按GBF执行。天然气水露点的测定应每天一次水露点的测定应按GBF执行。天然气烃露点的测定宜每月一次烃露点的测定可参照GBF执行。天然气的取样应按GBF执行取样点应在合同规定的天然气交接点。当气源组成或气体性质发生变化时应及时取样分析。气质分析和气质监测资料应及时整理、汇集、存档。工程预验收投产前的工程预验收管道线路工程应符合SY的规定。线路跨越工程应钧合SY的规定。线路穿越工程应符合SYF的规定。输气管道站内工艺管道工程验收应符合SY的规定。输气管道干线及站内工艺管网和设施的阴极保护应符合SY)的规定。干燥管道在投人使用前应进行干燥干燥宜在严密性试验结束之后进行。应利用清管器干燥清出管道内的游离水应保证清管器的密封性清管器运行速度宜控制在为mslmso干燥后应保证管道末端管内气体在最高输送压力下的水露点比最低环境温度低℃。管道干燥方法参见附录Ao试运投产翰气站试运试运条件:输气站试运应在站内工艺管线试压合格后进行。单体试运:压缩机组、工艺设备等试运应按设计及设备操作手册执行。在规定时间达到设计指标。变配电系统、消防系统、通信系统应执行国家和行业相关标准试运调试合格。供热、压缩空气、水等辅助系统试运合格。仪表及监控系统单独调试合格。整体试运:按设计工况进行各流程试运站内工艺管线、设备、仪表、站控、SCADA系统调试合格系统连续平稳运行h为合格。置换管道内空气的置换应在强度试压、严密性试验、吹扫清管、干燥合格后进行。管道内空气应采用氮气或其他无腐蚀、无毒害性的惰性气体作为隔离介质。置换过程中不同气体间界面宜采用隔离球或清管器隔离。置换空气时氮气或惰性气体的隔离长度应保证到达置换管线末端空气与天然气不混合。置换过程中管道内气流速度不应大于mso置换过程中混合气体应排至放空系统放空。放空口应远离交通线和居民点应以放空口为中心设立半径为m的隔离区。放空隔离区内不允许有烟火和静电火花产生。置换管道末端应配备气体含量检测设备当置换管道末端放空管口气体含氧量不大于时即可认为置换合格。利用管道内气体置换输气站工艺管线及设备内气体。wwwegascnSY邝投产天然气置换完成后即可投产。开启用户阀门调节供气压力直至正常。投产后按规定进行巡检测取各种参数填写报表。运行管理基本要求管道运行工艺计算见附录氏管道运行压力不应大于管道最高允许工作压力。管道内天然气温度应小于管线、站场防腐材料最高允许温度并保证管道热应力符合设计要求。管道宜采用SCADA系统对管线生产运行实现监控。应根据管道运行压力、温度、全线设备状况和季节特点通过优化运行进行调峰。a)地下储气库是天然气管道的组成部分对因季节性用气量波动较大地区宜设置地下储气库进行调峰b)在不具备建设地下储气库的天然气消费地区应考虑采用其他设施和方法调峰。应建立各种原始记录、台账、报表要求格式统一、数据准确并有专人负责。调度管理调度指令:调度指令只能在同一输气调度指挥系统中自上而下下达。调整运行参数由值班调度负责下达。变更天然气运销计划、输气生产流程、运行方式及特殊情况下的调度指令由调度长批准后下达。紧急调度指令由值班调度决定和传达用于管道事故状态或管道运行受到事故威胁的情况下。现场人员应及时采取应急措施防止事态扩大并及时向上级汇报。调度指令可以书面或电话形式下达。接受调度指令的单位应及时反馈执行情况。在运行管道进行作业性试验或检测时管道运行参数或运行方式的调整必须由调度统一指挥。调度通信除正常的专用通信外还应备有应急通信信道保证通信畅通。运行分析:应定期分析管道的输送能力和生产能力利用率。应及时分析设备、管道运行效率下降的原因并提出改进方案。应分析全线和压缩机组之间负载分配优化运行确保输送定量气体的动力消耗(总能耗费用)最小实现在稳定输量下压缩机组的最优匹配。当输气工况发生变化后应及时分析使输气管道从初始状态尽快转换到新的稳定状态并使新工况的实际运行参数与规定的运行参数的偏差最小和输气费用最小。应对清管效果和管道输送效率下降的因素进行及时分析。应定期对管道水力及温度、气质参数进行分析及时掌握管道泄漏和可能造成的堵塞等异常现象并及时确定泄漏或堵塞位置。管线在技术改造后应对管线运行进行全面分析。应根据管道内检测、外防腐层调查、管输介质组成、管材特性、管道沿线自然和社会状况等定期对管道的安全可靠性进行分析与评价。气量调配:wwwegascnSYT根据输供气合同应制定合理的输供气计划和运行方案。当输供气计划发生变化时应根据管输系统现状和用户类别及时调整运行方案。当运行方案发生变化时应提前与上游供气方和下游用户协调做好气量调配工作。自动化管理各种仪表及自动化设施管理应符合SYI'的规定确保现场检测仪表性能完好和正确设置。应配备专业人员对SCADA系统进行日常维护。管道维护与管理管道保护:管道保护应执行《石油天然气管道保护条例》。管道保护应由专业人员管理。定期进行巡线雨季或其他灾害发生时要加强巡线检查。巡线检查内容应包括:a)埋地管线无裸露防腐层无损坏b)跨越管段结构稳定构配件无缺损明管无锈蚀c)标志桩、测试桩、里程桩无缺损d)护堤、护坡、护岸、堡坎无垮塌e)管道两侧各m线路带内禁止种植深根植物禁止取土、采石和构建其他建筑物等f)管道两侧各m线路带内禁止开山、爆破和修筑大型建筑物、构筑物工程。穿越管段应在每年讯期过后检查每年一年应进行一次水下作业检查。检查穿越管段稳管状态、裸露、悬空、移位及受流水冲刷、剥蚀损坏情况等。检查和施工宜在枯水季节进行。跨越管段及其他架空管段的保护按SY'执行。管道内防护:根据输送天然气气质情况可使用缓蚀剂保护管道内壁。天然气在输送过程中宜再次分离、除尘、排除污物。当管道内有积水或污物时要及时进行清管作业。冬季要防止水化物堵塞管道可向管道内加注防冻剂。管道防腐:管道阴极保护率开机率大于管道外防腐应采用绝缘涂层与阴极保护相结合的方法。阴极保护极化电位应控制在一V一一V站场绝缘、阴极电位、沿线保护电位应每月测次管道防腐涂层、沿线自然电位应每年检测次。石油沥青防腐涂层破损、检修按SYT和SY'的规定执行。其他类型的外防腐层破损、检修按SYT的规定执行。管道检测:新建管线应在年内进行一般性检测以后根据管道运行安全状况每年一年检测次。新建管线应在年内进行全面性检测以后根据管道运行安全状况确定全面检测周期最多不应超过年。应分析检测结果建立管道检测档案原始数据及数据分析结果应存档。定期对管道年龄、等级位置、应力水平、泄漏历史、阴极保护、涂层状况、输送介质和环境因素的影响进行评价确定管道修理类型和使用寿命。站场管理一般要求:wwwegascnSYT站场管网和钢质设备必须采取防腐保护措施站场地面管网及设备涂色按SY'的规定执行。站内电气设备管理应符合SYiI'的规定。站场管网、设备的改造动火应符合设备管理要求和SYJ的规定。应根据气温对管线、站场设备采取防冻措施站场操作应避免产生静电和火花。站场应配备可燃气体检测仪。站场管线、阀件应严密无泄漏。站场设备、仪表应按规定进行接地接地电阻应符合要求并定期检测。应按规定配备消防器材。应根据运行压力对管道和设备配置安全泄放装置并定期进行校验。定期测试压力调节器、限压安全切断阀、安全泄放阀参数设置。设备管理:应配备足够的设备配件。管道通用阀门的操作、维护和检修应符合SYNC的规定。压缩机组等重要设备的操作、维护、修理应制定相应的操作规程建立设备档案。设备运行应按有关规定不得超温、超压、超速、超负荷运行重要设备应有安全保护装置。设备保养做到清洁、润滑、紧固、调整、防腐。离心式压缩机应避免喘振。管线、站场设置的截断阀、球阀、放空阀、排污阀、快速开关盲板等重要设备应定期操作作好记录。设备修理应实行计划预防修理、保养修理、预防维修相结合。设备修理前要对设备的运行情况、工作精度、磨损或腐蚀程度进行检查和监测。设备修理应实行运检双方交接制按有关质量标准和安全规定执行。计量管理天然气计量必须遵守国家计量法律、法规和检验、检定规程。计量器具的配备应符合SYT的规定。孔板流量计计量方法按SYT的规定执行其他类型流量计的使用应符合设备使用要求每月对孔板流量计进行一次检测。应定期检定、校准计量仪器、仪表保证量值准确。清管运行管道的清管周期:根据管道输送的气质组成、管道的输送效率和输送压差确定合理的清管周期。当管道输送效率。小于。时宜进行清管。历次清管记录:清管前应掌握管道历次清管记录如管道输气流量、管道输送压差、输送效率等。清管设施:首次清管应进行管道状况调查对于不符合清管要求的设施进行整改。清管前和清管过程应进行水力学计算预测和掌握清管器的位置(参见附录B)o清管器运行速度一般宜控制在msmso应根据清管器运行速度、推球平均压力、管径估算清管所需的推球输气流量。如果管道内污物、积液较多高程差较大应注意气量的储备。应估算清管器所需总运行时间。清管器的选择:wwwegascnSYP清管器宜安装发讯装置便于跟踪定位。根据管道状况和清管器特性选择清管器。可选择清管球、皮碗清管器、直板清管器或结合使用。选择清管器过盈量:a)清管球注满水过盈量为一b)皮碗、直板清管器过盈量为一‘清管器运行监测:应以管道的全面调查资料和实际情况为依据设置监听点。在中间阀室、支线、穿跨越、高程差较大管段等特殊地点应设监听点。监听点应配备信号接收装置和通过指示仪。清管末站放空与排污:放空、排污应符合安全、环保要求。应估算放空气量做好准备。应估算排污量做好污物、污液处理准备。对硫化物含量较高的天然气管道在打开收球筒前应对收球筒喷水湿式作业防止硫化亚铁自燃。清管过程注意事项及问题处理:清管过程中应随时掌握清管压差及变化情况。清管器被卡后可根据运行情况采取发第二清管器或提高清管器后运行压力及降低清管器前压力的办法。以上方法均无法解卡时采取割管取清管器的办法处理。管道维(抢)修天然气管道应根据所输介质的物理和化学组成管道沿线自然、社会情况和事故类型编制泄漏、断裂等事故预案。应根据事故预案配备维(抢)修设备和器材设置维(抢)修机构。管道维修(抢修)工程完毕后应按规定组织现场验收并将全部修理、验收资料存档。运行管道试压一般要求:管道所经过地区的等级划分应按照GB中执行。在压力条件下工作的管线应进行强度试压随后进行严密性试验。强度试压介质:a)试压用水不应有腐蚀性不应含有机或无机脏物水的允许pH值应为水中有害盐类的含量特别是氯化物应低于mgLob)如果最低环境温度不大于'C应允许使用含有结冰抑制剂的水。c)可采用水或空气及其他非易燃、无毒气体做强度试压介质。严密性试验宜采用气体作为试验介质。试压仪表:a)试压用仪表必须校验合格后才允许使用。b)试压用压力表的精度不应低于级量程为被测最大压力的倍一倍分度值不应大于MPa表盘直径不应小于rnmoc)每段试压管线安装的压力表不应少于只管线两端应各安装只对试压段高程差较大的管段应在管段最高点和最低点各安装只压力表。d)试压用温度计的分度值应不大于C,测量范围应满足测量要求。e)试压温度计应安装在无阳光照射的地方否则应采取遮阳措施每段试压管线安装的温度计wwwegascnSYT不应少于支管线两端应各安装支。试压压力值的测量应以管道最高点测出的压力值为准且低点处管道的环向应力不得超过管材本身的屈服强度与焊缝系数的乘积。强度试压、严密性试验中管线如有泄漏应泄压后修补修补合格后应重新试压(验)。预制件、地上管路或完全暴露的但尚未埋地的管线在强度试压稳压期间此系统中的试验介质会受热膨胀应采取措施避免超压。分段强度试压合格的管线间相互连接的焊缝应进行射线或其他无损探伤检验并合格在全线贯通后可不再进行强度试压。严密性试验可在分段强度试压合格后进行也可在全线贯通后进行。穿(跨)越管线强度试压、严密性试验:穿(跨)越管线应单独进行强度试压。强度试压宜采用洁净水做试压介质试压压力不应小于最大工作压力的倍应在试压压力下稳压h严密性试验压力不应小于最大工作压力应在试验压力下稳压ho穿(跨)越管线与全线连通后宜再进行一次严密性试验。线路强度试压、严密性试验:应按不同地区级别的管线并结合地形分段进行强度试压。同一地区级别管线也应分段进行强度试压分段长度根据试压介质不同而不同。一、二级地区的管线可采用空气或水做试压介质。三、四级地区的管线宜采用水做试压介质。水试压:a)用水做试压介质的管段每段长度不宜超过km并且试压管段高差不应超过mb)试压充水应加人密封性良好的隔离球或皮碗清管器防止空气存于管内应尽可能避免在管线高点开孔排气。隔离球或皮碗清管器可在试压后取出。c)试压压力应均匀缓慢上升当压力升至试验压力时应停止升压min进行检查然后升压至试验压力时再停止min进行检查最后升至试压压力并稳压。停止升压期间应检查管线压力有无异常现象。d)架空输气管道采用水试压前应核算管道及其支撑结构的强度必要时应临时加固防止管道及支撑结构受力变形。e)在试压压力下稳定h压降值不大于试压压力且不大于MPa为合格。f)试压合格后应将管段内积水清扫干净。气体试压:a)用气体做试压介质的管段每段长度不宜超过kmob)试压压力应均匀缓慢上升每小时升压不超过MPaoc)当试压压力低于MPa时分两次升压:在压力为试压压力时稳压min若未发现问题继续升压至试压压力。d)当试压压力大于MPa时分三次升压:在压力为试压压力时稳压min进行检查然后继续升压至试压压力时再停止znin进行检查最后升至试压压力并稳压。停止升压期间应检查管线压力有无异常现象。e)在试压压力下稳定h以管道不破裂、无渗漏为合格。最大强度试压压力:a)一级地区内的管线不应小于最大工作压力的倍。b)二级地区内的管线不应小于最大工作压力的倍。wwwegascnS、一Tc)三级地区内的管线不应小于最大工作压力的倍。d)四级地区内的管线不应小于最大工作压力的倍。严密性试验:a)严密性试验压力为管道的最大工作压力。b)进行严密性试验的管线在试验压力下应稳压h并且压降不大于试验压力值为合格(压降率计算见附录c)输气站强度试压、严密性试验:站内工艺管线应按压力等级、设备、管件、阀门等的不同压力要求分段或单独进行强度试压和严密性试验强度试压:a)站内的工艺管线宜采用水做强度试压介质。b)采用水试压时升压应缓慢达到强度试压压力后应稳压min检查无泄漏、无压降为合格。c)采用气体试压时应分段进行并用发泡剂检漏。升压应缓慢系统可先升到强度试压压力进行稳压检漏无泄漏无异常时再按强度试压压力的逐级升压每级应稳压并检漏合格直至升至强度试压压力并稳压至少min。每次稳压时间应根据所用发泡剂检漏工作需要的时间而定但不应少于lmin}d)站内阀门等设备的强度试压应单独进行试压压力应按设备(或设计)要求进行。e)强度试压压力不应小于最大工作压力的倍且不低于MPao严密性试验:a)宜采用气体为试验介质当达到试验压力后应稳压min经检查无泄漏为合格。b)当用天然气做试验介质时应在完成干燥和置换了管内空气后进行。c)严密性试验压力应按最大工作压力进行且不低于MPao安全要求:试压(验)期间管线两侧各loom应设为隔离区非工作人员应远离该区域。采用气体做强度试压介质时当管线环向应力首次从钢材规定的最低屈服强度的提高到最高试压压力直到压力降至最大工作压力这段时间内不允许工作人员沿管线检查。如必须进行检查应考虑降低强度试压压力。如采用天然气做严密性试验介质隔离区内还应严禁烟火和静电火花。wwwegascnSYT附录A(资料性附录)管道干燥方法A干燥空气脱水干燥法(干空气加清管器组成清管干燥列车)A利用干空气推动清管干燥列车沿管道运行当清管干燥列车的最后一个清管器到达干燥管段的终端后将管道中压力降到一定值。A利用干空气进行低压干燥吹扫直到达到所需标准。A氮气干燥法A氮气干燥法与干燥空气脱水干燥方法相同(由于氮气露点更低故干燥效果更好)。A氮气干燥后可免去置换作业实现管道的直接投产。A大型管道干燥用氮气量很大应对制备氮气的经济性进行分析。A真空干燥法A降压(抽空)阶段:将压力从管道的初始压力降低到管壁温度下水蒸气的饱和压力。A沸腾(蒸发)阶段:重复抽真空和隔离过程保持管道内压力为降压阶段末的压力值。A干燥阶段:用真空泵将管道内压力降低到与所需露点(干燥指标通常为一`C)相对应的水蒸气饱和压力。将管道密封隔离检测管道内压力重复抽真空直至检测到管内压力没有明显上升为止:一:可在真空条件下直接引人天然气实现管道的投产。干燥所需时间取决于抽真空时间和蒸发过程所需时间。理论抽真空时间按式(Al)计算:」,‘抽一Q排‘‘p二(A)式中:t抽理论抽真空时间单位为小时(h)、一干燥管段的管容单位为立方米(m)Q排真空泵排量(Po二MPa,To=K)单位为立方米每小时(m小)Po抽真空前管道内压力单位为千帕(kPa)p抽真空结束管道内压力单位为千帕(kPa)o理论蒸发时间按式(A)计算:W。t,j=lesl侧排、N(A)式中:t理论蒸发时间单位为小时(h)w干燥管段的含水量单位为千克(kg)P管壁温度和蒸发压力下水蒸气的饱和密度单位为千克每立方米(kgm)wwwegascnSYlAAAA质。脱水清管列车干燥法用天然气驱动甲醇(或乙二醇等)脱水清管列车实现。一次实现清管、脱水、干燥、置换、投产作业缩短了管道投产时间。凝胶结合脱水清管列车法可减轻清管器磨损防止密封性能不佳收集管壁铁锈等机械杂wwwegascnSYT附录B{规范性附录)管道运行工艺计算B输气f计算当管段起点与终点的相对离差Ah镇m时的计算式Q=Ed"pi一pzZTLGo·“““·‘·············⋯⋯(B)式中:Q气体流量(p=MPa,T=K)单位为立方米每天(md)d输气管内直径单位为厘米(cm)p,p输气管段内起点、终点气体压力(绝)单位为兆帕(MPa)Z气体的压缩系数T气体的平均温度单位为开尔文(K)L输气管计算段长度单位为千米(km)G气体的相对密度E输气管的效率系数当DN为时E=当。N>时E=一B当管段起点与终点的相对高差Ah>m时的计算式QEd叫赢丁p,p(aAh)石石ZTLGOfaf',(hh,)L、二)、L‘七二一Ja=(GZT)式中:a系数单位为米一'(m')Ah输气管终点和起点的标高差单位为米(m)输气管沿线高差变化所划分的计算段数h,h‘一各分管段终点和起点的标高单位为米(m)L各分管段长度单位为千米(km)BB管道运行压力计算管道内平均压力计算式(不考虑节流效应)Pm二了PiPPiP·‘’‘’“‘’‘二“················⋯⋯(B)式中:Pm管道内气体平均压力(绝)单位为兆帕Pi,P管道计算段内起点、终点气体压力MPa)(绝)单位为兆帕(MPawwwegascnSYPB管道沿线任意点气体压力计算式PX一丫:一(:一。XL······························⋯⋯(B)式中:PX一管道沿线任意娜体压力(绝)单位为兆帕(MPa)X管道计算段起点全沿线任意点的长度单位为千米(km)B管道内气体温度计算(不考虑节流效应)B管道内气体平均温度计旅式‘土兰」二生ot,一山‘m一‘。‘Q乙、几一‘。xKD‘详p式中:t,一管道计算段内气体的平均温度单位为摄氏度(℃)to管道埋设处的土坡温度单位为摄氏度(℃)t管道计算段内起点气体温度单位为摄氏度(℃)二自然对数底数e=。一计算常数K管道内气体到土壤的总传热系数单位为瓦每平方米摄···························⋯⋯(B)氏度【W(mz"'C)D管道外直径单位为米(m)Cp气体的定压比热单位为焦耳每千克摄氏度J(kgB管道沿线任意点气体盆度计算式tx=to(t一to)e'c式中:tX管道沿线任意点气体沮度单位为摄氏度沈℃)。BA管道的储气f计算式Qu*黔不夸一赞}·价“·······⋯⋯(B)tu}、},z式中:QM管道的储气量(po=MPa,To=K)单位为立方米(m)V管道容积单位为立方米(m)ToKPO一一MPaT气体的平均温度单位为开尔文(K)pm一一管道计算段内气体的最高平均压力(绝)单位为兆帕(MPa)wwwegascnSY月Pm管道计算段内气体的最低平均压力(绝)单位为兆帕(MPaZ对应p九m时的气体压缩系数。B输差计算式B输气且差值计算式Q差=(V,Q,)一(QQQ砚)式中:Q差某一时间输气管道内平衡输气量之差值单位为立方米(m)Qt同一时间内的输人气量单位为立方米(m)Q同一时间内的输出气量单位为立方米(m)Q同一时间内输气单位的生产、生活用气量单位为立方米(m)Q同一时间内放空气量单位为立方米(m)V,计算时间开始时管道计算段内的储存气量单位为立方米(m)V计算时间终了时管道计算段内的储存气量单位为立方米〔m)注:气体体积的标准参比条件是po=MPa,To=KB相对翰差计算式·一(B)认几QxVlQl⋯⋯(B)式中:I相对输差。B管道输送能力利用率计算式:一R}x(B夕式中:I管道年输送能力利用率Q}管道实际输送气量(po=MPa,To=K),单位为立方米每年(m年)Qaw道设计输送气童(po=MPa,To=K)单位为立方米每年(m'Y)oB管道输送效率计算式一念式中:一一管道输送效率Q计在同一运行工况下管道计算输送气量(p。二。MPa,立方米每天(md)o几=K),(B)单位为wwwegascnSY汀BB管道清管计算式清管大压差估算公式p二p广十p犷p犷·····。······················一(B)式中:p最大压差单位为兆帕(MPa)p犷清管器的启动压差单位为兆帕(MPa)P当前收、发站之间输气压差单位为兆帕(MPa)P估算管内最大的积液高程压力(绝)单位为兆帕(MPaB清管气f估算公式B清管推球输气流f估算公式Qft二OF·歹·v······························⋯⋯(B)式中:Q估输气流量峥=MPa,To=K)单位为立方米每天(md)F管道内径横截面积单位为平方米(m)p清管器后平均压力单位为兆帕(MPa)v清管器运行平均速度单位为千米每小时(kmh)oB洛管总进气估笠公式Q总:式中:Q,g总进气量(p=MPa,L‘清管器运行距离单位为千米BS浩怜器选行时间估旅公式OOOOF·L"·多(B)TO=K)单位为立方米(m)(km)式中:t清管器运行时间单位为小时(h)v清管器运行平均速度单位为千米每小时(kmhB清管器运行距离估且公式IM只些翼臀I································⋯⋯(B)"uaOP式中:It清管器运行距离单位为米(M)Po一一一MPaToKwwwegascnSYTT清管器后管段内气体平均温度单位为开尔文(K)Q进发清管器后的累计进气量(po=MPa,To=K)单位为立方米(m)d输气管内直径单位为米(m)R一一B清管器运行速度估算公式B输气流f可计算下的瞬时速度公式一一一旦一D、口一F·p一、ui式中:v清管器运行速度单位为千米每小时(km币)。B输气流不可计组下的谏赌公式v一子·······································⋯⋯(B)式中:v清管器平均运行速度单位为米每秒(ms)t运行距离的实际时间单位为秒(s)B放空气计旅公式Q一dXpZG······························⋯⋯(B)式中:Qlp天然气放空瞬时气量(po=MPa,To=K)单位为立方米每天(md)d放放空管出口端内径单位为毫米(mm)p放在距离放空管口倍管内径处测得压力(绝)单位为兆帕(MPa)owwwegascnSYPI'附录C(规范性附录)管道试压工艺计旅C管道允许压降率计算式IAPI=撰X·································⋯⋯(C)式中:EAPJ允许压降率DN钢管公称直径单位为毫米(

用户评价(1)

关闭

新课改视野下建构高中语文教学实验成果报告(32KB)

抱歉,积分不足下载失败,请稍后再试!

提示

试读已结束,如需要继续阅读或者下载,敬请购买!

文档小程序码

使用微信“扫一扫”扫码寻找文档

1

打开微信

2

扫描小程序码

3

发布寻找信息

4

等待寻找结果

我知道了
评分:

/21

SYT 5922-2003天然气管道运行规范

VIP

在线
客服

免费
邮箱

爱问共享资料服务号

扫描关注领取更多福利