gJ
中华人民共和国城镇建设行业标准
CJ/T 212-2005
聚 合 物 基 复 合 材 料 水 算
Water grate made of polymer matrix composites
2005-05-16发布 2005-10-01实施
中华人民共和国建设部 发 布
CJ/T 212-2005
目 次
前言 ·················································································································⋯⋯ m
1 范围 ··············································································································⋯⋯ 1
2 规范性引用文件 ·····。···················。·································································⋯⋯“ ‘1
3 术语 ··············································································································⋯⋯ 1
4 产品基本参数、编号和承载等级说明········································································⋯⋯ 3
5 技术要求 ·····································································································⋯⋯ 4
6试验装置及试验方法 ························································································⋯⋯5
7 检验规则 ·········································································································⋯⋯ 7
8 标志、合格证和贮存、运输 ········································································⋯⋯‘二‘二““二8
????? www.bzfxw.com ????
CJ/T 212-2005
前 言
聚合物基复合材料产品经过多年实践,因其独有的一些特点,现已在全国各地得到广泛应用。鉴于
各个城市、各部门所制定的使用标准不统一,阻碍了聚合物基复合材料产品的进一步发展,为了规范聚
合物基复合材料水算的使用,根据废弃物资源化国家工程研究中心多年的研究成果和生产实践,在广泛
征求市政设计、产品维护等部门以及众多施工单位、生产厂家的意见的基础上,借鉴铸铁井盖标准,特制
定本标准 。
本标准由建设部标准定额研究所提出。
本标准由建设部给水排水产品标准化技术委员会归口。
本标准由废弃物资源化国家工程研究中心、中国物资流通技术开发协会、上海市市政工程研究院、
上海市市政工程行业协会、西安市市政设计研究院、广西城乡规划设计院、南宁市城市规划设计院、重庆
市设计院、成都市城市建设科学研究院起草。
本标准主要起草人:孙可伟、李如燕、赵众、牟惟仲、吴初航、顾民治、杨新义、林吉中、陆际汉、
胡金兰、汤浩、张劲文。
CJ/T 212-2005
聚 合 物 基 复 合 材 料 水 算
范 围
本标准规定了聚合物基复合材料水算的分类、承载等级、技术要求、试验方法、检验规则及标
志等。
本标准适用于安装在各种路面上的各个部位(包括道路、公路两边及中间,绿地,厂房车间的室内地
面等)的聚合物基复合材料水算。
2 规范性引用文件
下列文件中的条款通过本标准的引用而成为本标准的条款。凡是注日期的引用文件,其随后所有
的修改单(不包括勘误的内容)或修订版均不适用于本标准,然而,鼓励根据本标准达成
协议
离婚协议模板下载合伙人协议 下载渠道分销协议免费下载敬业协议下载授课协议下载
的各方研究
是否可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本标准。
GB 6414-1999 铸件 尺寸公差与机械加工余量
GB 8810 硬质泡沫塑料吸水率试验方法
GB/T 1040 塑料拉伸试验方法
GB/T 1041 塑料压缩试验方法
GB/T 1043 硬质塑料简支梁冲击试验方法
GB/T 9341 塑料弯曲试验方法
GB/T 16422. 2-1999 塑料实验室光源暴露试验方法 第二部分:氛弧灯
CJ/T 3012-1993 铸铁检查井盖
CJJ 37-1990 城市道路设计规范
术语
3.1
排水口 out fall
污水、雨水等流人地下排水设施的人口。
3.2
水算 water grate
排水口上放置的排水设施,由支座和算子组成。
3.2.1
支座 set
水算中固定于排水口的部分,用于安放算子。
3.2.2
算子 grate
水算中未固定部分。其功能是排水、截留较大杂物进人排水口,需要时能够开启。
3.3
嵌入深度 inlaid depth
支座支承面至支座顶面的高度。如图1所示A值。
????? www.bzfxw.com ????
CJ/T 212- 2005
算子
支座
图 1
缝宽a width of aperture
支座与算子之间的间隙,a=a,+a2,见图
3. 5
支座支承面 supporting face of set
支承算子的支座平面,其宽度如图1中的b值
3. 6
水算接触面 interface for water grate
算子与支座支承面相接触 的平 面
3. 7
水算公称尺寸(mm x mm) nominal size of water grate
水算上沿的实际尺寸,如图2中的LXW值。
匕 ) ( )
( ) ( )
( ) ( )
图 2
3. 8
水算净尺寸(mm x mm) net size of water grate
也就是排水口的尺寸,见图1、图4中的D, XD,值
水算锥度 taper of water grate
水算上下沿形成的锥度,如图3中的0角的正切值tgoa
试验载荷 testing load
在测试水算承载能 力时规定施 加的荷载。
CJ/T 212-2005
图 3
一 一 一一 一 }!“2
〔二二二二〕 (二二二二二三) }{
图 4
3. 11
聚合物基复合材料 polymer matrix composites
聚合物基复合材料是利用聚合物和各种颗粒、纤维、金属等填充增强材料,通过少量添加剂及一定
工艺的作用生产出的材料。聚合物基复合材料的主要原料也可用各种废弃聚合物及废弃的颗粒、纤维
代替。
4 产品基本参数、编号和承载等级说明
4. 1 聚合物基复合材料水算基本参数及尺寸应符合表1规定。
表 1
名 称 数 值
水算公称尺寸长L 400,450,500,550,600,650.700
水算公称尺寸宽 W 300,350,400
注:如有特殊需求,水算规格可根据用户需求调整。
4.2 产品编号
聚合物基复合材料水算的编号由产品代号((JSB);主要参数:水算公称尺寸长L (mm) X宽w
(mm);承载等级;重型(Z)、普型(P)、轻型(Q);三部分组成。
等级:重型(Z)、普型(P)、轻型(Q)
参数:水算公称尺寸长(MM) X宽(MM)
代 号:(JSB)
????? www.bzfxw.com ????
CJ/T 212- 2005
任标记示例
JSB-700 X 300-Q
JSB一产品代号;700 X 300一水算公称尺寸(mmxmm);Q 轻型.
4.3 承载等级说明
聚合物基复合材料水算按其承载能力不同主要分为重型(Z),普型(P)、轻型(Q)三个等级(见表2),
表 2
等级 标志 对应最高城市道路分类等级 参考设置场合
重型 z 快速路以上 货运站、码头等重型车较多的道路、场地
普型 P 快速路 车流量大的机动车行驶、停放的道路、场地
轻型 Q 次干路 工级 小型车慢速行走的道路、场地,居民小区,绿地等一般场所
技术要求
5.1 原材料
聚合物基复合材料水算主要使用聚合物和填充增强材料制作。
a) 聚合物:各种高分子材料及其再生品;
b) 填充增强材料:各种颗粒状、纤维状材料及其再生品,各种金属及构件。
5.2 聚合物基复合材料水算的形状宜为矩形。
5.3 算子与支座间的缝宽应符合表3的要求,算子上沿尺寸大于下沿尺寸,锥度宜为1:20-1:5,
表 3
水算公称尺寸长L/(mm) 宽边缝宽-a, +a2 (mm)
L=D, +2b-a, -a, (1^-2)%L
水算公称尺寸宽W/ (mm) 长边缝宽 a =a, +.z (mm)
W=从 +2b-a, -a2 (1-2)%W
注:锥度较大时,a值可相对取小一些;锥度较小时,a值可取大些。
5.4 支座支承面的宽度应符合表4的要求。
表 4
水算公称尺寸长L/ (mm) 支座宽边支承面宽度b/ (mm)
L=D, +2b-a, -.a )4写L
水算公称尺寸宽W/(mm) 支座长边支承面宽度b八mm)
W =D2 +2b-a, -a2 妻4%W
5.5 水算的嵌人深度。重型、普型水算不应小于50 mm,轻型水算不应小于30 mm,
5.6 算子与支座表面应压制平整,不应有裂纹、凹凸不平等影响水算使用性能的缺陷。
5.7 算子与支座装配结构尺寸应符合GB 6414的要求。其公差等级不应低于GB 6414-1999中
CT10的规定并保证算子与支座的互换性。
5.8 水算采用四面收水方式排水,排水孔宽度不应大于32 mm.
5.9 水算排水面积(即水算上所有排水孔面积之和)应占到水算净尺寸(D, X DZ)的25%以上。
5.10 水算的承载能力和破坏载荷应符合表5的规定。
CJ/T 212-2005
表 5
水 算等级 试验载荷/(kN) 破坏载荷//(kN) 允许残留变形//(mm)
重 型 9O 妻130 (1%500)D,
普 型 70 妻100 (1/500)D,
轻 型 50 )70 (1/500)D
6 试验装置及试验方法
6. 1 聚合物基复合材料水算应按复合材料主要性能指标、承载性能、耐热性能、抗冻性能、耐候性能、抗
疲劳性能等检测项目进行试验。
6.2 聚合物基复合材料主要性能指标见表60
表 6
项 目 t 能 指 标 制样侧试标准
弯 曲强度 平均值妻22 MPa,单块最小值)18 MPa GB/T 9341
冲击强 度 平均值)lo'i/m ,单块最小值)6 X to01/ml GB/T 1043
压缩 强度 平均值)25 MPa,单块最小值妻20 MPa GB/T 1041
拉伸 强度 平均值)10 MPa,单块最小值)8 MPa GB/T 1040
弹性模 量 平均值妻1 000 MPa,单块最小值)600 MP,,(弯曲弹性模量) GB/T 9341
吸水率 Q % GB 8810
耐酸性 试样在 20%硫酸溶液中浸泡 48 h,表面无明显腐蚀 质量损失<1%
耐碱性 试样在 20 %氢氧化钠溶液中浸泡48 h,表面无腐蚀。质量损失<1%
耐热性 破坏载荷下载镇5% 见本标准 6.4
耐候性 破坏载荷下降簇5% 见本标准 6.6
6.3 承载性能试验
6.3. 1 按成套产品进行承载能力试验,如果只检测算子,则应四边支承,支承面宽度应符合表4的
规定 。
6.3.2 加载设备:加载设备所能施加的载荷不应小于300 kN,其台面尺寸应大于水算支座最外缘尺
寸。测力仪器的误差应低于士2%,加载试验装置如图5。
加载
刚性垫块
台面
图 5
6.3.3 试验装置附件
a) 刚性垫块
????? www.bzfxw.com ????
CJ/T212一2005
刚性垫块有两块,尺寸应为300mmx400mm和3O0mm火ZO0mm,厚度等于或大于4Omm、上下
表面平整。见图6。
b) 橡胶垫片
在刚性垫块与水算之间放置一块弹性橡胶垫片,垫片的平面尺寸应与刚性垫块相同,垫片厚度应为
6mm~ 10mm
IX 45. 全部1喇
? _生
-
\lx魂5.
300X400
图 6
c) 附件的使用条件
当水算净尺寸DI)soomm且DZ)400mm时,使用尺寸为30Ommx400mm的刚性垫块,否则
使用尺寸为30OmmX200mm的刚性垫块。
6.3.4 试验程序
6.3.4.1 调整刚性垫块的位置,使其中心与水算的几何中心重合。放置后,垫块长边应与水算长边平
行,垫块宽边应与水算宽边平行。
6.3.4.2 在施加2/3试验荷载后,水算残留变形的测量。
以IkN/5一3kN/5的速度加载,加载至2/3试验荷载,然后卸载。此过程重复进行 5次。
第一次加载前与第5次加载后的变形之差为残留变形,其值不允许超过表5中的规定。
6.3.4.3 以上述相同的速度加载至表5规定的试验荷载,smin后卸载,算子、支座不应出现裂纹。
6.4 耐热性能试验
6.4.1 试验装置及要求
高低温试验箱,试验控制温度80℃士2℃,试验持续时间168h(7d)。试样为水算。
6.4.2 试验方法
样品在高低温试验箱中80℃士2℃条件下保持168h,然后在室温下冷却24h。测试结果以破坏载
荷的相对变化率表示。
6.5 抗冻性能试验
6.5.1 试验装置及要求
高低温试验箱,试验控制温度一40℃士2℃。试样为水算。
6.5.2 试验方法
样品在高低温试验箱中一40℃士2℃条件下保持48 h,然后迅速取出安放到加载试验装置上,测试
其破坏载荷,结果以相对变化率表示。
6.6 耐候性能试验
6.6.1 试验装置及要求
氨灯气候模拟试验箱,要求有调温调湿装置、喷水装置、氖弧灯光源装置。
6.6.2 试验方法
水算在氨灯照射及雨淋的条件下持续500 h后,在常温下室内放置24 h。测试结果以破坏载荷的
相对变化率表示
试验条 件:
C1/T 212-2005
a)氛弧灯照射温度:60℃士50C;
b) 湿度:65%士5%;
c) 光照度:550 W/m};
d) 喷水时间:18 min士0. 5 min,两次喷水之间的无水时间:102 min士0. 5 min;
e) 试样旋转速率:1 r/min.
6.7 抗疲劳性能试验
6.7.1 试验装置及要求
动态结构试验机,要求具有载荷、位移、应变及计算函数等多种控制模式,设备所能施加的最大载荷
不应低于200 kNa
6.7.2 试验方法
当使用尺寸为300 mm X400 mm的刚性垫块时,在水算上施以频率为。. 2 Hz、峰值为70 kN的标
准三角波形变动载荷(见图7a);当使用尺寸为300 mm X200 mm的刚性垫块时,在水算上施以频率为
0.2 Hz、峰值为35 kN的标准三角波形变动载荷(见图76)。进行2.5X105次的疲劳循环试验后,在室
内放置24 h.测试结果以破坏载荷的相对变化率表示。
变动载荷
(‘N) 变动载荷
(kN)
时间(s)
7-5 10 12
、时间(s)
15
7.5 10 12.5 15
图 7a 图 7b
6.7.3 要求
要求疲劳循环试验后,水算的承载性能下降小于5%。在疲劳循环试验的进行过程中,若设备意外
出现停顿,每次停顿时间不得超过5 min且一个水算试验过程中不得有超过3次的停顿,否则必须更换
水算重新进行 试验。
检验规则
产品检验分为出厂检验和型式检验。
7. 1 批量与抽样
按批量采用随机抽样方法取样。
产品以同一规格、同一原材料在相似条件下生产的水算构成批量。生产批量:以300套为一批,不
足该数量时按一批计;
7.2 出厂检验
包括产品尺寸偏差、外观质量和强度的检验。
7.2.1 按5.3-5.9的要求,对水算、支座逐一检查。
7.2.2 承载能力试验时,每批产品随机抽取3套进行承载能力试验。如有一套不符合5. 10的要求,则
再抽取3套,重复本项试验。如再有一套不符合要求,则该批水算为不合格。
7.2.3 每批产品必须有该批材质的检验报告。
????? www.bzfxw.com ????
CI/T 212-2005
7.3 型式检验
7.3. 1 有下列情况之一时,应进行型式检验:
a) 新产品投产前鉴定;
b) 正常生产情况下每两年至少进行一次;
c) 原料、设备及生产工艺发生变化时;
d) 产品长期停产后,恢复生产时;
e) 出厂检验结果与上次型式检验有较大差异时;
f) 国家质量监督检验机构提出进行型式检验时。
7.3.2 按6.2的要求检测材料性能,材料性能有一项不合格,则该批产品不合格。
7.3.3 按5.3^-5. 9的要求,对每一批量随机抽取5%逐套检查。如果有3套及以下不符合要求,则该
批产品可视为合格。有3套以上(不含3套)不符合要求,则该批水算不合格。
7.3.4从7.3.3抽取的水算中,随机抽取3套进行承载能力试验。如有一套不符合5.10的要求,则再
抽取3套重复本项试验。如再有一套不符合要求,则该批水算不合格。
7.3.5从7. 3.3抽取的水算中,随机抽取3套进行耐热试验。如有一套破坏载荷下降>5%,则再抽取
3套重复本项试验。如再有一套不符合要求,则该批水算不合格。
7.3.6从7.3.3抽取的水算中,随机抽取3套进行抗冻试验。如有一套破坏载荷下降>5%,则再抽取
3套重复本项试验。如再有一套不符合要求,则该批水算不合格。
7.3.7 从7.3.3抽取的水算中,随机抽取3套进行耐候试验。如有一套破坏载荷下降>5%,则再抽取
3套重复本项试验。如再有一套不符合要求,则该批水算不合格。
7.3.8从7.3. 3抽取的水算中,随机抽取3套进行抗疲劳试验。如有一套破坏载荷下降>5%,则再抽
取3套重复本项试验。如再有一套不符合要求,则该批水算不合格。
7.4 型式检验不合格时,该产品应立即停止生产。采取措施后,须再次进行型式检验,合格后方能正式
投人 生产。
标志 、合格证和贮存 、运输
1 标 志
1.1 每个算子上必须具有清楚且永久性的下列标志:
a) 产品标记;
b) 制造厂名或商标;
c) 生产年、月。
1.2 每个支座上必须有清楚且永久性的下列标志:
a) 产品标记;
b) 生产年、月。
1.3 每个合格的算子、支座上必须有检验人员打的合格标记。
2 合格证
出厂产品应配有合格证,合格证应包含以下内容:
a) 生产厂家;
b) 该批产品的名称、规格、数量;
c) 注明符合的检验标准(本标准);
d) 合格证编号;
e) 检验员章;
f) 检验部门章或检验专用章;
只) 出厂 日期 。
?
??
?
CJ/T 212-2005
8.3 贮存
a) 在仓库或露天按规格分类堆放;
b) 贮存地应远离火源和热源,环境温度不应高于60'C.
8.4 运输和装卸
运输时无需包装。人工装卸时,严禁扔上扔下,以免损坏;当用叉车装卸时,层高不应高于10层,产
品底部应有托架 。
????? www.bzfxw.com ????