首页 独立避雷针

独立避雷针

举报
开通vip

独立避雷针独立避雷针 ERITECHDISTRIBUTOR CONFERENCE 代理商会议 2008ERITECH Isolated Down-conductor System The IEC Protection by Isolation concept IEC标准里有关独立 防雷的 概念。 -avoids electrifying the telecoms mast but here requires a separate mast to achieve this -需要一个独立的杆柱避免通 信天线竿充电。ERIT...

独立避雷针
独立避雷针 ERITECHDISTRIBUTOR CONFERENCE 代理商会议 2008ERITECH Isolated Down-conductor System The IEC Protection by Isolation concept IEC 标准 excel标准偏差excel标准偏差函数exl标准差函数国标检验抽样标准表免费下载红头文件格式标准下载 里有关独立 防雷的 概念。 -avoids electrifying the telecoms mast but here requires a separate mast to achieve this -需要一个独立的杆柱避免通 信天线竿充电。ERITECH Isolated Down-conductor System The IEC Protection by Isolation concept IEC标准里有关独立 防雷的 概念。 -Using ISODC avoids electrifying the telecoms mast and DOES NOT require a separate mast to achieve this -可以采用ISODC独立防雷系 统来避免通信天 线竿充电, 但却不需要独立的杆柱。ERITECH Isolated Down-conductor System In order to do this the ISODC cable must 为达到这点,ISODC电缆必须能: …provide an equivalent electrical separation distance to the air breakdown distance… 提供大约空气 绝缘击穿距离的等效电气隔离距离 Testing procedure 测试程序If the parallel air gap breaks down repeatedly before the cable then the equivalentsafety distance of the cable is greater than the air gap distance.如果平行的空气间隙再三先于电缆被击穿,那说明电 缆的等效安全距离大于空气间隙距离。Protection Angle Method 保护角原理IEC 62305-3 Protection Angle IEC 62305-3 保护角ERITECH Isolated Down-conductor System The Protection Angle needs to be calculated to protect the equipment. 要通过计 算来确定保护设备 的保护角。 As height h gets greater protection angle o gets smaller. 高度h越高,保护角o越小 Protection angles from Installation Manual 安装手册中得到 的保护角截闪器高度 距离dm和保护角o 未保护 的区域 被保护 的区域ERITECH Isolated Down-conductor System The maximum allowable cable length depends on the chosen Lightning Protection Level. 最大允许电缆长度取决于所选择的雷电保 护等 级。 雷电保护等级 最大隔离下导体长度 L,计算隔 离距离用的 下终端头 下导 体距离 目前的雷电 保护系统 安装图最小 2米 ALOFIGS 杆柱抱箍 ISOMMB50 附件 ACF-2-GS 附件Upper arrangement 上终端安装 15mm1m铝杆 固定螺母 不锈 钢垫圈 杆柱帽带螺纹固定针 最终ISODC 隔离杆柱 Primary bonding connection 主 要连接 主要等电位连接连接导体 螺丝钉连接器Lower termination下终端连接 带螺 纹螺栓固定 扭距 8 NmERITECH Isolated Down-conductor System 工厂安装的上终 端头 客户组装的下终端头 Factory upper termination Customer lower termination 主 要等电位连接 下终端头调节器 上终端头调节器 上终端头 ISODC is usually sold pre-terminated ISODC通常预先组装出售Fitting Lower termination 下终端头装配 Cutting and preparing cable 切割并准备电缆Fitting Lower termination 下终端头装配 Attach fitting and tighten locking screws 安装和固定螺丝Fitting Lower termination 下 终端头装配 Tape off to seal 打开胶带来密封 Use with AS/NZS 1768 适用于 AS/NZS 1768The ISODC concept is supported byand compliant with AS/NZS 1768ISODC 也适用于AS/NZS 17684.16.2 Prevention of side-flashing4.16.2 防止侧闪 4.16.2.1 Methods of prevention4.16.2.1防止侧闪的原理“Two methods exist to prevent side-flashing: bonding and isolation.”两种防止侧闪的方法:连接和隔离“If the structure is constructed with conductive materials such as reinforced concrete or steelframes isolation of a protection system mounted on the structure requires the use of highimpulse strength high voltage insulation.”如果建筑物有钢筋或钢构架等导电物质,隔离安装在 建筑上的保护系统需要运用高冲击强度,高电压绝缘。4.16.2.3 Isolation 隔离 “Isolation may be provided by appropriate air clearance from bare metal downconductors or byappropriately insulated downconductors. The requirements for insulated downconductorsare detailed in IEC 62305.3.”可以采用与裸金属下导体一定空气距离 或合适绝缘下导体来进行隔离。在IEC 62305.3上对绝缘下导体的要求有详细描述。 Use with AS/NZS 1768 适用于AS/NZS 1768When designing to AS/NZS 1768 the Rolling Sphere methodmust be used not the Protection Angle method.按照AS/NZS 1768 涉及时,必须采用滚球法(而不是保护角法)。
本文档为【独立避雷针】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_686908
暂无简介~
格式:doc
大小:17KB
软件:Word
页数:0
分类:生活休闲
上传时间:2018-01-12
浏览量:18