首页 RMP-111D

RMP-111D

举报
开通vip

RMP-111D DEIF A/S Tel: (+45) 9614 9614 Frisenborgvej 33, DK-7800 Skive Fax: (+45) 9614 9615 Denmark E-mail: deif@deif.com D EI F A /S Installation and start up instructions Overload relay type RMP-111D uni-line 4189340123E (UK) ...

RMP-111D
DEIF A/S Tel: (+45) 9614 9614 Frisenborgvej 33, DK-7800 Skive Fax: (+45) 9614 9615 Denmark E-mail: deif@deif.com D EI F A /S Installation and start up instructions Overload relay type RMP-111D uni-line 4189340123E (UK) • Protection of prime mover • 3 phase measurement • LED indication of fault condition • Timer controlled tripping • LED indication for activated relay • 35 mm DIN rail or base mounting Page 2 of 4 Tel. (+45) 9614 9614 • Fax: (+45) 9614 9615 • E-mail: deif@deif.com Mounted voltage module Contact remains locked in alarm position even though the input returns to normal. Latch circuit is reset by disconnecting the supply voltage. Distributor’s ID No. Filled in by distributor when customizing the unit. Measuring voltage Coupling (set by DEIF) Supply voltage Type designation DEIF’s order ack. No. To be stated when contacting DEIF Highest voltage in relation to earth Installation category Special calibration (if non-standard calibration is applied) Scaling 1 (for adaption of the unit to the measuring power) Calibrated secondary power of the relay Mounted standard current module Relay coupling Shown is relay B as a normally de-energised relay, relay C as a normally energised relay with latch circuit 1. Description This protective overload relay type RMP-111D forms part of a complete DEIF series (the uni-line) of relays for protection and control of generators. 2. Label The relay is provided with a label with the following data: Note 1: Calculation of measuring power: ”X” x voltage module x current module x scale = measuring power ”X” is replaced by 2 for coupling 2W3 3 for couplings 1W3, 1W4, 3W3 and 3W4 Note: The relay is provided with a 200 ms power-up relay, ensuring correct function of the relay on connection of the auxiliary voltage. Normally energised contacts (”NE”) are not activated (contact does not open/close) until 200 ms after connection of the auxiliary voltage. Likewise, the relay is provided with a 200 ms power-down circuit, ensuring supervision and maintenance of any set point exceeding for 200 ms after disconnection of the auxiliary voltage. Installation and start up instructions RMP-111D 4189340123E (UK) 3. Mounting instructions The RMP-111D is designed for panel mounting, being mounted on a 35 mm DIN rail, or by means of two 4-mm screws. Weight: Approx. 0.650 kg The design of the relay makes mounting of it close to other uni-line units possible, however make sure there are min. 50 mm between the top and bottom of this relay and other relays/units. The DIN rail must always be placed horizontally when several relays are mounted on the same rail. 4. Connection diagram 2W3 3W3(4) A 2A fuse may protect all voltage inputs. The relay is protected against ESD (electrostatic electricity), and further special protection against this during the mounting of the relay is not necessary. Coupling Applied for measurement on 3W3 3 phase networks without neutral 3W4 3 phase networks with neutral If neutral is not accessible, the connection to terminal No. 16 (neutral) may be omitted without this affecting the accuracy of the relay, provided that the 3 phase voltages are identical. Page 4 of 4 Tel. (+45) 9614 9614 • Fax: (+45) 9614 9615 • E-mail: deif@deif.com For relays with coupling 2W3 the voltage inputs are connected as follows, if the current transformers are placed in other phases than indicated in the above diagram: External current transformer Connect - connected to L1 (23 + 24), and to L2 (29 + 30) L1 to term. No. 17 L3 to term. No. 19 L2 to term. No. 21 - connected to L2 (23 + 24), and to L3 (39 + 30) L2 to term. No. 17 L1 to term. No. 19 L3 to term. No. 21 5. Start up instructions 5.1 Setting and indication Setting of LED/relay Overload set point: (25…125%) of Pn ”P>” Yellow LED is lit when the set point has been exceeded, but the output contact has not yet been activated. Time delay: 0…20 s The contact is activated and the red LED is lit after the timer has expired. When setting the set points on the front of the RMP-111D an accuracy of ±5% of the scaling may normally be obtained. If a higher accuracy is required, the unit (the generator) connected to the relay must be loaded by means of a load bank. When the power exceeds the set point, the yellow LED of the RMP-111D is lit. 6. Technical specifications Overload, currents: 4 x In, continuously 20 x In for 10 s (max. 75A) 80 x In for 1 s (max. 300A) Load: Max. 0.5VA per phase Overload, voltages: 1.2 x Un, continuously 2 x Un for 10 s Load: 2kΩ/V Frequency range: 40…45…65…70Hz Relay contact: 1 changeover switch Contact ratings: 250V-8A-2000A (AC), 24V-8A-200W (DC) Contact voltage: Max. 250V (AC). Max 150V (DC) Response time: <400 ms Galv. separation: Between inputs, outputs and aux. supply: 3250V-50Hz-1 min. Consumption: (Aux. supply) 3.5VA/2W
本文档为【RMP-111D】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_634613
暂无简介~
格式:pdf
大小:221KB
软件:PDF阅读器
页数:0
分类:交通与物流
上传时间:2011-04-23
浏览量:10