[日本经济产业省原子力安全保安院]《新闻发布·地震损坏信息(第28次发布)》[20110318]E 1 March 18, 2011 Nuclear and Industrial Safety Agency Seismic Damage Information (the 28th Release) (As of 17:30 March 17th, 2011) Nuclear and Industrial Safety Agency (NISA) confirmed the current situation of Onagawa NPS, Tohoku ...

[日本经济产业省原子力安全保安院]《新闻发布·地震损坏信息(第28次发布)》[20110318]E
1 March 18, 2011 Nuclear and Industrial Safety Agency Seismic Damage Information (the 28th Release) (As of 17:30 March 17th, 2011) Nuclear and Industrial Safety Agency (NISA) confirmed the current situation of Onagawa NPS, Tohoku Electric Power Co. Inc.; Fukushima Dai-ichi and Fukushima Dai-ni NPSs, Tokyo Electric Power Co. Inc. (TEPCO); Tokai Dai-ni NPS, Japan Atomic Power Co. Inc. as follows: Major updates are as follows. 1. Nuclear Power Stations (NPS)  Fukushima Dai-ichi NPS ・ 4 times of seawater discharge to Unit 3 by the helicopters of Self-Defence Force (9:48, 9:52, 9:58, 10:01 March 17th) ・ Arrival of the riot police at the site for grand discharge (16:10 March 17th) ・ Cable installation to receive electricity from the transmission line of Tohoku Electric Power Company. Schedule to be connected to Unit 2 after the completion of discharge work. (17:30 March 17th) ・ Emergency Diesel Generator (1 unit) for Unit 6 operable. Supplying electricity to Unit 5 and 6. Water injection to Spent Fuel Pool through the Make up Water Condensate System (MUWC) progressing. Schedule to inject water to the Reactor Pressure Vessel (RPV) after the recovery of external power source. 2 1. The status of operation at NPS (Number of automatic shutdown units: 10)  Fukushima Dai-ichi NPS, TEPCO (Okuma Town and FutabaTown, Futaba County, Fukushima Prefecture) (1) The status of operation Unit 1 (460MWe): automatic shutdown Unit 2 (784MWe): automatic shutdown Unit 3 (784MWe): automatic shutdown Unit 4 (784MWe): in periodic inspection outage Unit 5 (784MWe): in periodic inspection outage Unit 6 (1,100MWe): in periodic inspection outage (2) Major Plant Parameters (12:00 March 17th) Unit 1 Unit 2 Unit 3 Unit 4 Unit 5 Unit 6 Reactor Pressure [MPag] 0.173 (A) 0.144(B) -0.029(A) -0.047(B) 0.014 (A) 0.023(A) - 1.100 0.740 CV Pressure (D/W) [kPa] Not available 115 190 - - - Reactor Water Level*1 [Mm] -1,800(A) -1,800(B) -1,800(A) Not available(B) -1,950(A) -2,300(B) - 1,870 1,309 Suppression Pool Water Temperature (S/C) [℃] - - - - - - Suppression Pool Pressure (S/O) [kPa] Not available down scale down scale - - - Spent Fuel Pool Water Temperature [℃] - - - 84 64.2 62.5 Time of Measurement 11:30 March 17th 11:30 March 17th 11:10 March 17th 04:08 March 14th 12:00 March 17th 12:00 March 17th *1: Distance from the top of fuel (3) Report concerning other incidents ・ TEPCO reported to NISA the event in accordance with the Article 10 of the Act on Special Measures Concerning Nuclear Emergency 3 Preparedness regarding Fukushima Dai-ichi. (15:42 March 11th) ・ TEPCO reported to NISA the event (Loss of reactor cooling function) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Units 1 and 2 of Fukushima Dai-ichi. (16:36 March 11th) ・ The cable for receiving electricity from the transmission line of Tohoku Electric Power Company was installed. It is scheduled to be connected to Unit 2 after the completion of discharge work. (17:30 March 17th) ・ Seawater was injected to RPV via the Fire Extinguishing System Line (Started up 11:55 March 13th) →Temporary interruption of the injection (01:10 March 14th) ・ The sound of explosion in Unit 1 occurred. (15:36 March 12nd) ・ Seawater is being injected as of 17:30 March 17th. ・ Water injection function was sustained. (14:00 March 13th) ・ Reactor water level was decreasing. (13:18 March 14th) TEPCO reported to NISA the event (Loss of reactor cooling functions) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness. (13:49 March 14th) ・ Seawater injection to RPV was ready through the Fire Extinguishing System line. (19:20 March 14th) ・ TEPCO evaluated core damage of Unit 2 was “less than 5%” (22:14 March 14th) ・ Water level in RPV in Unit 2 is decreasing. (22:50 March 14th) ・ A sound of explosion was made in Unit 2. As the pressure in Suppression Chamber decreased (06:10 March 15th), there was a possibility that an incident occurred in the Chamber. (06:20 March 15th) ・ Seawater is being injected as of 17:30 March 17th. ・ Fresh water was injected to RPV via the Fire Extinguishing System 4 Line (FESL). (11:55 March 13th) ・ Seawater was injected to RPV via FESL. (13:12 March 13th) ・ Injection of seawater for Unit 1 and Unit 3 to the Primary Containment Vessel (PCV) was interrupted due to the lack of seawater in pit. (01:10 March 14th) ・ For Unit 3 injection of seawater into PCV was restarted (03:20 March 14th) ・ The pressure in PCV of Unit 3 rose unusually. (7:44 March 14th) TEPCO reported to NISA the event (Loss of reactor cooling function) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness. (7:52 March 14th) ・ For Unit 3 the explosion like Unit 1 occurred around the Reactor Building (11:01 March 14th) ・ The white smoke like steam generated from Unit 3. (08:30 March 16th) ・ Because of the possibility that PCV of Unit 3 was damaged, the workers evacuated from the central control room of Unit 3 and 4 (common control room). (10:45 March 16th) Thereafter the operators returned to the room and restarted the operation for water injection. (11:30 March 16th) ・ Seawater was discharged 4 times to Unit 3 by the helicopters of Self-Defence Force. (9:48, 9:52, 9:58 and 10:01 March 17th) ・ The riot police arrived at the site for grand discharge. (16:10 March 17th) ・ Seawater is being injected to RPV as of 17:30 March 17th. ・ It was confirmed that a part of wall in the operation area of Unit 4 was damaged. (06:14 March 15th) ・ The fire at Unit 4 occurred. (09:38 March 15th) TEPCO reported that the fire was extinguished spontaneously. (11:00 March 15th) ・ The temperature of water in the Spent Fuel Storage Pool at Unit 4 had increased. (84 ℃ at 04:08 March 14th) ・ The fire occurred at Unit 4. (5:45 March 15th) TEPCO reported that no fire could be confirmed on the ground.(06:15 March 16th) ・ The water injection is suspended as of 17:30 March 17th. 5 ・ Emergency Diesel Generator (1 unit) for Unit 6 is operable and supplying electricity to Units 5 and 6. Water injection to the Spent Fuel Pool through MUWC is progressing. It is scheduled to inject water to RPV after the recovery of external power source.  Fukushima Dai-ni NPS (TEPCO) (Naraha Town / Tomioka Town, Futaba County, Fukushima Prefecture.) (1) The status of operation Unit1 (1,100MWe): automatic shutdown, cold shut down at 17:00, March 14th Unit2 (1,100MWe): automatic shutdown, cold shut down at 18:00, March 14th Unit3 (1,100MWe): automatic shutdown, cold shut down at 12:15, March 12th Unit4 (1,100MWe): automatic shutdown, cold shut down at 07:15, March 15th (2) Major plant parameters (As of 17:00, 17 March) unit Unit 1 Unit 2 Unit 3 Unit 4 Reactor Pressure MPag 0.09 0.04 0.04 0.06 Reactor water temperature ℃ 44.5 43.0 26.8 40.6 Reactor water level* mm 10,796 11,246 7,516 8,893 Suppression pool water temperature ℃ 34 28 43 39 Suppression pool pressure kPa 132 121 136 134 Remarks cold shutdown cold shutdown cold shutdown cold shutdown *: Distance from the top of fuel (3) Report concerning other incidents ・ TEPCO reported to NISA the event in accordance with the Article 10 of 6 the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Unit 1 of Fukushima Dai-ni NPS. (18:08 March 11th) ・ TEPCO reported to NISA the events in accordance with the Article 10 regarding Units 1, 2 and 4 of Fukushima Dai-ni NPS. (18:33 March 11th) ・ TEPCO reported to NISA the event (Loss of pressure suppression function) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Unit 1 of Fukushima Dai-ni NPS. (5:22 March 12th) ・ TEPCO reported to NISA the event (Loss of pressure suppression function) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Unit 2 of Fukushima Dai-ni NPS. (5:32 March 12th) ・ TEPCO reported to NISA the event (Loss of pressure suppression function) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Unit 4 of Fukushima Dai-ni NPS. (6:07 March 12th)  Onagawa NPS (Tohoku Electric Power Co. Inc.) (Onagawa Town, Oga County and Ishinomaki City, Miyagi Prefecture) (1) The status of operation Unit 1 (524MWe): automatic shutdown, cold shut down at 0:58, March 12th Unit 2 (825MWe): automatic shutdown, cold shut down at earthquake Unit 3 (825MWe): automatic shutdown, cold shut down at 1:17, March 12th (2) Readings of monitoring post Reading of monitoring post: MP2 (Monitoring at the North End of Site Boundary) approx. 6,500 nGy/h (19:00 March 14th) →approx. 5,400 nGy/h (19:00 March 15th) (3) Report concerning other incidents ・ Fire Smoke on the first basement of the Turbine Building was confirmed 7 to be extinguished. (22:55 on March 11th) ・ Tohoku Electric Power Co. reported to NISA in accordance with the Article 10 of the Act on Special Measures Concerning Nuclear Emergency Preparedness. (13:09 March 13th) 2. Action taken by NISA (March 11th) 14:46 Set up of the NISA Emergency Preparedness Headquarters (Tokyo) immediately after the earthquake 15:42 TEPCO reported to NISA in accordance with the Article 10 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Fukushima Dai-ichi NPS. 16:36 TEPCO recognized the event (Loss of cooling function) in accordance with the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Units 1 and 2 of Fukushima Dai-ichi NPS. (Reported to NISA at 16:45) 18:08 Regarding Unit 1 of Fukushima Dai-ni NPS, TEPCO reported to NISA in accordance with the Article 10 of the Act on Special Measures Concerning Nuclear Emergency Preparedness. 18:33 Regarding Units 1, 2 and 4 of Fukushima Dai-ni NPS, TEPCO reported to NISA in accordance with the Article 10 of Act on Special Measures Concerning Nuclear Emergency Preparedness. 19:03 Government declared the state of nuclear emergency. (Establishment of Government Nuclear Emergency Response Headquarters and Local Emergency Response Headquarters) 20:50 Fukushima Prefecture’s Emergency Response Headquarters issued a direction for the residents within 2 km radius from Unit 1 of Fukushima Dai-ichi NPS to evacuate. (The population of this area is 1,864.) 21:23 Directives from Prime Minister to the Governor of Fukushima Prefecture, the Mayor of Okuma Town and the Mayor of Futaba Town were issued regarding the event occurred at Fukushima Dai-ichi NPS, TEPCO, in accordance with the Paragraph 3, the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness as follows: - Direction for the residents within 3km radius from Unit 1 to 8 evacuate - Direction for the residents within 10km radius from Unit 1 to stay in-house 24:00 Vice Minister of Economy, Trade and Industry, Ikeda arrived at the Local Emergency Response Headquarters (March12th) 05:22 Regarding Unit 1 of Fukushima Dai-ni NPS, TEPCO recognized the event (Loss of pressure suppression function) to fall under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness. (reported to NISA at 06:27) 05:32 Regarding Unit 2 of Fukushima Dai-ni NPS, TEPCO recognized the event (Loss of pressure suppression function) to fall under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness. 05:44 Residents within 10km radius from Unit 1 of Fukushima Dai-ichi NPS shall evacuate by the Prime Minister Direction. 06:07 Regarding of Unit 4 of Fukushima Dai-ni NPS, TEPCO recognized the event (Loss of pressure suppression function) to fall under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness. 06:50 In accordance with the Paragraph 3, the Article 64 of the Nuclear Regulation Act, the order was issued to control the internal pressure of the Containment Vessel of Units 1 and 2 of Fukushima Dai-ichi NPS. 07:45 Directives from Prime Minister to the Governor of Fukushima Prefecture, the Mayors of Hirono Town, Naraha Town , Tomioka Town and Okuma Town were issued regarding the event occurred at Fukushima Dai-ni NPS, TEPCO, pursuant to the Paragraph 3, the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness as follows: - Direction for the residents within 3km radius from Fukushima Dai-ni NPS to evacuate - Direction for the residents within 10km radius from Fukushima Dai-ni NPS to stay in-house 17:00 TEPCO reported to NISA the event (Unusual increase of radiation 9 dose at the site boundary) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Fukushima Dai-ichi NPS. 17:39 Prime Minister directed evacuation of the residents within the 10 km radius from Fukushima-Dai-ni NPS 18:25 Prime Minister directed evacuation of the residents within the 20km radius from Fukushima Dai-ichi NPS 19:55 Directives from Prime Minister was issued regarding seawater injection to Unit No.1 of Fukushima Dai-ichi NPS. 20:05 Considering the Directives from Prime Minister and pursuant to the Paragraph 3, the Article 64 of the Nuclear Regulation Act, order was issued to inject seawater to Unit 1 of Fukushima Dai-ichi NPS. 20:20 At Unit 1 of Fukushima Dai-ichi NPS, seawater injection started. (March 13th) 05:38 TEPCO reported to NISA the event (Total loss of coolant injection function) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Unit 3 of Fukushima Dai-ichi NPS. Recovering efforts by TEPCO of the power source and coolant injection function and work on venting are under way. 09:01 TEPCO reported to NISA the event (Unusual increase of radiation dose at the site boundary) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Fukushima Dai-ichi NPS. 09:08 Pressure suppression in the Containment Vessel and fresh water injection started at Unit 3 of Fukushima Dai-ichi NPS. 09:20 The Pressure Vent Valve of Unit 3 of Fukushima Dai-ichi NPS was opened. 09:30 The order was issued for the Governor of Fukushima Prefecture, the Mayors of Okuma Town, Futaba Town, Tomioka Town and Namie Town in accordance with the Act on Special Measures Concerning Nuclear Emergency Preparedness on the contents of radioactivity decontamination screening. 09:38 TEPCO reported to NISA that Unit 1 of Fukushima Dai-ichi NPS reached a situation specified in the Article 15 of the Act on Special 10 Measures Concerning Nuclear Emergency Preparedness. 13:09 Tohoku Electric Power Co. reported to NISA that Onagawa NPS reached a situation specified in the Article 10 of the Act on Special Measures Concerning Nuclear Emergency Preparedness. 13:12 Fresh water injection was switched to seawater injection at Unit 3 of Fukushima Dai-ichi NPS. 14:36 TEPCO reported to NISA the event (Unusual increase of radiation dose at the site boundary) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Fukushima Dai-ichi NPS. (March 14th) 01:10 Seawater injection at Unit 1 and Unit 3 of Fukushima Dai-ichi NPS were temporarily interrupted due to the lack of seawater in pit. 03:20 Seawater injection at Unit 3 of Fukushima Dai-ichi NPS was restarted. 04:40 TEPCO reported to NISA the event (Unusual increase of radiation dose at the site boundary) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Fukushima Dai-ichi NPS. 05:38 TEPCO reported to NISA the event (Unusual increase of radiation dose at the site boundary) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Fukushima Dai-ichi NPS. 07:52 TEPCO reported to NISA the event (Unusual rise of the pressure in PCV) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Unit 3 of Fukushima Dai-ichi NPS. 13:25 Regarding Unit 2 of Fukushima Dai-ichi NPS, TEPCO recognised the event (Loss of cooling function) to fall under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness. 22:13 TEPCO reported to NISA in accordance with the Article 10 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Fukushima Dai-ni NPS. 22:35 TEPCO reported to NISA the event (Unusual increase of radiation dose at the site boundary) falling under the Article 15 of the Act on 11 Special Measures Concerning Nuclear Emergency Preparedness regarding Fukushima Dai-ichi NPS. (March 15th) 00:00: The acceptance of experts from IAEA was decided. NISA agreed to accept the offer of dispatching of the expert on NPS damage from IAEA considering the intention by Mr. Amano, Director General of IAEA. Therefore, the schedule of expert acceptance will be planned from now on according to the situation. 00:00: NISA also decided the acceptance of experts dispatched from NRC. 07:21 TEPCO reported to NISA the event (Unusual increase of radiation dose at the site boundary) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Fukushima Dai-ichi NPS. 07:24 Incorporated Administration Agency, Japan Atomic Energy Agency (JAEA) reported to NISA in accordance with the Article 10 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding, Nuclear Fuel Cycle Engineering Laboratories, Tokai Research and Development Centre. 07:44 JAEA reported to NISA in accordance with the Article 10 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Nuclear Science Research Institute. 08:54 TEPCO reported to NISA the event (Unusual increase of radiation dose at the site boundary) falling under the Article 15 of the Act on Special Measures Concerning Nuclear Emergency Preparedness regarding Fukushima Dai-ichi NPS. 10:30 According to the Nuclear Regulation Act, Minister of Economy, Trade and Industry issued the directives as follows. For Unit 4: To extinguish fire and to prevent the occurrence of re-criticality For Unit 2: To inject water to reactor vessel promptly and to vent Drywell. 10:59 Considering the possibility of lingering situation, it is decided that the function of the Local Emergency Response Headquarter is moved to the Fukushima Prefectural Office. 12 11:00 Prime Minister directed the in-house stay area. In-house stay was additionally directed to the residents in the area from 20 km to 30 km radius from Fukushima Dai-ichi NPS considering in-reactor situation. 16:30 TEPCO reported to NISA the event (Unusual increase of radiation dose at the site boundary) falling under the Article 15 of the Act on Special Measures Concerning Nucl
本文档为【[日本经济产业省原子力安全保安院]《新闻发布·地震损坏信息(第28次发布)》[20110318]E】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_319544
暂无简介~
格式:pdf
大小:170KB
软件:PDF阅读器
页数:16
分类:生产制造
上传时间:2011-03-18
浏览量:9