首页 TLC549 datasheet

TLC549 datasheet

举报
开通vip

TLC549 datasheet TLC548C, TLC548I, TLC549C, TLC549I 8-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL SLAS067B – NOVEMBER 1983 – REVISED MAY 1996 1POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251–1443 � Microprocessor Periph...

TLC549 datasheet
TLC548C, TLC548I, TLC549C, TLC549I 8-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL SLAS067B – NOVEMBER 1983 – REVISED MAY 1996 1POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251–1443 � Microprocessor Peripheral or Standalone Operation � 8-Bit Resolution A/D Converter � Differential Reference Input Voltages � Conversion Time . . . 17 µs Max � Total Access and Conversion Cycles Per Second – TLC548 . . . up to 45 500 – TLC549 . . . up to 40 000 � On-Chip Software-Controllable Sample-and-Hold Function � Total Unadjusted Error . . . ±0.5 LSB Max � 4-MHz Typical Internal System Clock � Wide Supply Range . . . 3 V to 6 V � Low Power Consumption . . . 15 mW Max � Ideal for Cost-Effective, High-Performance Applications including Battery-Operated Portable Instrumentation � Pinout and Control Signals Compatible With the TLC540 and TLC545 8-Bit A/D Converters and with the TLC1540 10-Bit A/D Converter � CMOS Technology description The TLC548 and TLC549 are CMOS analog-to-digital converter (ADC) integrated circuits built around an 8-bit switched-capacitor successive-approximation ADC. These devices are designed for serial interface with a microprocessor or peripheral through a 3-state data output and an analog input. The TLC548 and TLC549 use only the input/output clock (I/O CLOCK) input along with the chip select (CS) input for data control. The maximum I/O CLOCK input frequency of the TLC548 is 2.048 MHz, and the I/O CLOCK input frequency of the TLC549 is specified up to 1.1 MHz. AVAILABLE OPTIONS T PACKAGE TA SMALL OUTLINE (D) PLASTIC DIP (P) 0°C to 70°C TLC548CDTLC549CD TLC548CP TLC549CP –40°C to 85°C TLC548IDTLC549ID TLC548IP TLC549IP Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. Copyright  1996, Texas Instruments Incorporated 1 2 3 4 8 7 6 5 REF+ ANALOG IN REF– GND VCC I/O CLOCK DATA OUT CS D OR P PACKAGE (TOP VIEW) TLC548C, TLC548I, TLC549C, TLC549I 8-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL SLAS067B – NOVEMBER 1983 – REVISED MAY 1996 2 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251–1443 description (continued) Operation of the TLC548 and the TLC549 is very similar to that of the more complex TLC540 and TLC541 devices; however, the TLC548 and TLC549 provide an on-chip system clock that operates typically at 4 MHz and requires no external components. The on-chip system clock allows internal device operation to proceed independently of serial input/output data timing and permits manipulation of the TLC548 and TLC549 as desired for a wide range of software and hardware requirements. The I/O CLOCK together with the internal system clock allow high-speed data transfer and conversion rates of 45 500 conversions per second for the TLC548, and 40 000 conversions per second for the TLC549. Additional TLC548 and TLC549 features include versatile control logic, an on-chip sample-and-hold circuit that can operate automatically or under microprocessor control, and a high-speed converter with differential high-impedance reference voltage inputs that ease ratiometric conversion, scaling, and circuit isolation from logic and supply noises. Design of the totally switched-capacitor successive-approximation converter circuit allows conversion with a maximum total error of ±0.5 least significant bit (LSB) in less than 17 µs. The TLC548C and TLC549C are characterized for operation from 0°C to 70°C. The TLC548I and TLC549I are characterized for operation from –40°C to 85°C. functional block diagram REF– 64 8 8 DATA OUT 8-Bit Analog-to Digital Converter (Switched- Capacitors) 8-to-1 Data Selector and Driver Output Data Regiser Internal System Clock Sample and Hold 7 5 2 3 1 ANALOG IN REF+ CS I/O CLOCK Control Logic and Output Counter typical equivalent inputs INPUT CIRCUIT IMPEDANCE DURING SAMPLING MODE INPUT CIRCUIT IMPEDANCE DURING HOLD MODE 1 kΩ TYP Ci = 60 pF TYP (equivalent input capacitance) 5 MΩ TYP ANALOG IN ANALOG IN TLC548C, TLC548I, TLC549C, TLC549I 8-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL SLAS067B – NOVEMBER 1983 – REVISED MAY 1996 3POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251–1443 operating sequence tenten tsu(CS) B7 B0B1B2B3B4B5B6B7 Conversion Data B MSBMSB LSB Hi-Z State MSBLSB (see Note B) MSB Previous Conversion Data A A7 A7 A6 A5 A4 A3 A2 A1 A0 Hi-Z State Don’t 11 (see Note A) tconv tsu(CS) Access Cycle B 8 8765432765432 CLOCK I/O CS OUT DATA Care Sample Cycle B Access Cycle C Sample Cycle C twH(CS) NOTES: A. The conversion cycle, which requires 36 internal system clock periods (17 µs maximum), is initiated with the eighth I/O clock pulse trailing edge after CS goes low for the channel whose address exists in memory at the time. B. The most significant bit (A7) is automatically placed on the DATA OUT bus after CS is brought low. The remaining seven bits (A6–A0) are clocked out on the first seven I/O clock falling edges. B7–B0 follows in the same manner. absolute maximum ratings over operating free-air temperature range (unless otherwise noted) Supply voltage, VCC (see Note 1) 6.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Input voltage range at any input –0.3 V to VCC + 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output voltage range –0.3 V to VCC + 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Peak input current range (any input) ±10 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Peak total input current range (all inputs) ±30 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating free-air temperature range, TA (see Note 2): TLC548C, TLC549C 0°C to 70°C. . . . . . . . . . . . TLC548I, TLC549I –40°C to 85°C. . . . . . . . . . . . Storage temperature range, Tstg –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NOTES: 1. All voltage values are with respect to the network ground terminal with the REF– and GND terminals connected together, unless otherwise noted. 2. The D package is not recommended below –40°C. TLC548C, TLC548I, TLC549C, TLC549I 8-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL SLAS067B – NOVEMBER 1983 – REVISED MAY 1996 4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251–1443 recommended operating conditions TLC548 TLC549 UNIT MIN NOM MAX MIN NOM MAX UNIT Supply voltage, VCC 3 5 6 3 5 6 V Positive reference voltage, Vref+ (see Note 3) 2.5 VCC VCC+0.1 2.5 VCC VCC+0.1 V Negative reference voltage, Vref– (see Note 3) –0.1 0 2.5 –0.1 0 2.5 V Differential reference voltage, Vref+, Vref– (see Note 3) 1 VCC VCC+0.2 1 VCC VCC+0.2 V Analog input voltage (see Note 3) 0 VCC 0 VCC V High-level control input voltage, VIH (for VCC = 4.75 V to 5.5 V) 2 2 V Low-level control input voltage, VIL (for VCC = 4.75 V to 5.5 V) 0.8 0.8 V Input/output clock frequency, fclock(I/O) (for VCC = 4.75 V to 5.5 V) 0 2.048 0 1.1 MHz Input/output clock high, twH(I/O) (for VCC = 4.75 V to 5.5 V) 200 404 ns Input/output clock low, twL(I/O) (for VCC = 4.75 V to 5.5 V) 200 404 ns Input/output clock transition time, tt(I/O) (for VCC = 4.75 V to 5.5 V) (see Note 4 and Operating Sequence) 100 100 ns Duration of CS input high state during conversion, twH(CS) (for VCC = 4.75 V to 5.5 V) (see Operating Sequence) 17 17 µs Setup time, CS low before first I/O CLOCK, tsu(CS) (for VCC = 4.75 V to 5.5 V) (see Note 5) 1.4 1.4 µs Operating free-air temperature TA TLC548C, TLC549C 0 70 0 70 Operating free-air temperature, TA TLC548I, TLC549I –40 85 –40 85 °C NOTES: 3. Analog input voltages greater than that applied to REF+ convert to all ones (11111111), while input voltages less than that applied to REF– convert to all zeros (00000000). For proper operation, the positive reference voltage Vref+, must be at least 1 V greater than the negative reference voltage, Vref–. In addition, unadjusted errors may increase as the differential reference voltage, Vref+ – Vref– , falls below 4.75 V. 4. This is the time required for the I/O CLOCK input signal to fall from VIH min to VIL max or to rise from VIL max to VIH min. In the vicinity of normal room temperature, the devices function with input clock transition time as slow as 2 µs for remote data acquisition applications in which the sensor and the ADC are placed several feet away from the controlling microprocessor. 5. To minimize errors caused by noise at the CS input, the internal circuitry waits for two rising edges and one falling edge of internal system clock after CS↓ before responding to control input signals. This CS setup time is given by the ten and tsu(CS) specifications. TLC548C, TLC548I, TLC549C, TLC549I 8-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL SLAS067B – NOVEMBER 1983 – REVISED MAY 1996 5POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251–1443 electrical characteristics over recommended operating free-air temperature range, VCC = Vref+ = 4.75 V to 5.5 V, fclock(I/O) = 2.048 MHz for TLC548 or 1.1 MHz for TLC549 (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP† MAX UNIT VOH High-level output voltage VCC = 4.75 V, IOH = –360 µA 2.4 V VOL Low-level output voltage VCC = 4.75 V, IOL = 3.2 mA 0.4 V IOZ High-impedance off-state output current VO = VCC, CS at VCC 10 µAIOZ High-impedance off-state output current VO = 0, CS at VCC –10 µA IIH High-level input current, control inputs VI = VCC 0.005 2.5 µA IIL Low-level input current, control inputs VI = 0 –0.005 –2.5 µA II(on) Analog channel on-state input current during Analog input at VCC 0.4 1 µAII(on) Analog channel on state input current duringsample cycle Analog input at 0 V –0.4 –1 µA ICC Operating supply current CS at 0 V 1.8 2.5 mA ICC + Iref Supply and reference current Vref+ = VCC 1.9 3 mA Ci Input capacitance Analog inputs 7 55 pFCi Input capacitance Control inputs 5 15 pF operating characteristics over recommended operating free-air temperature range, VCC = Vref+ = 4.75 V to 5.5 V, fclock(I/O) = 2.048 MHz for TLC548 or 1.1 MHz for TLC549 (unless otherwise noted) PARAMETER TEST CONDITIONS TLC548 TLC549 UNITPARAMETER TEST CONDITIONS MIN TYP† MAX MIN TYP† MAX UNIT EL Linearity error See Note 6 ±0.5 ±0.5 LSB EZS Zero-scale error See Note 7 ±0.5 ±0.5 LSB EFS Full-scale error See Note 7 ±0.5 ±0.5 LSB Total unadjusted error See Note 8 ±0.5 ±0.5 LSB tconv Conversion time See Operating Sequence 8 17 12 17 µs Total access and conversion time See Operating Sequence 12 22 19 25 µs ta Channel acquisition time (sample cycle) See Operating Sequence 4 4 I/O clock cycles tv Time output data remains valid after I/O CLOCK↓ 10 10 ns td Delay time to data output valid I/O CLOCK↓ 200 400 ns ten Output enable time 1.4 1.4 µs tdis Output disable time S Fi 1 150 150 ns tr(bus) Data bus rise time See Figure 1 300 300 ns tf(bus) Data bus fall time g 300 300 ns † All typicals are at VCC = 5 V, TA = 25°C. NOTES: 6. Linearity error is the deviation from the best straight line through the A/D transfer characteristics. 7. Zero-scale error is the difference between 00000000 and the converted output for zero input voltage; full-scale error is the difference between 11111111 and the converted output for full-scale input voltage. 8. Total unadjusted error is the sum of linearity, zero-scale, and full-scale errors. TLC548C, TLC548I, TLC549C, TLC549I 8-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL SLAS067B – NOVEMBER 1983 – REVISED MAY 1996 6 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251–1443 PARAMETER MEASUREMENT INFORMATION See Note B 0.4 V 2.4 V tf(bus) Output tr(bus) 0.8 V 2.4 V 0.8 V td DATA OUT VOLTAGE WAVEFORMS FOR RISE AND FALL TIMES VOLTAGE WAVEFORMS FOR DELAY TIME VCC 3 kΩ 3 kΩ VCC See Note B 50% 50% 0 V 0 V tPLZ I/O CLOCK VOLTAGE WAVEFORMS FOR ENABLE AND DISABLE TIMES Output Waveform 1 (see Note C) tPHZ VOH90% 10% tPZL 0 V VCC 50% CS LOAD CIRCUIT FOR tPZL AND tPLZ LOAD CIRCUIT FOR tPZH AND tPHZ LOAD CIRCUIT FOR td, tr, AND tf See Note B Output Under Test Test Point 3 kΩ 1.4 V Output Waveform 2 (see Note C) CL (see Note A) Output Under Test Test Point CL (see Note A) Output Under Test Test Point CL (see Note A) tPZH 50% NOTES: A. CL = 50 pF for TLC548 and 100 pF for TLC549; CL includes jig capacitance. B. ten = tPZH or tPZL, tdis = tPHZ or tPLZ. C. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. Figure 1. Load Circuits and Voltage Waveforms TLC548C, TLC548I, TLC549C, TLC549I 8-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL SLAS067B – NOVEMBER 1983 – REVISED MAY 1996 7POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251–1443 APPLICATIONS INFORMATION simplified analog input analysis Using the equivalent circuit in Figure 2, the time required to charge the analog input capacitance from 0 to VS within 1/2 LSB can be derived as follows: The capacitance charging voltage is given by VC = VS 1–e –tc/RtCi( ) (1) where Rt = Rs + ri The final voltage to 1/2 LSB is given by (2)VC (1/2 LSB) = VS – (VS/512) Equating equation 1 to equation 2 and solving for time tc gives VS –(VS/512) = VS 1–e (3)–tc /RtCi( ) and tc (1/2 LSB) = Rt × Ci × ln(512) (4) Therefore, with the values given the time for the analog input signal to settle is tc (1/2 LSB) = (Rs + 1 kΩ) × 60 pF × ln(512) (5) This time must be less than the converter sample time shown in the timing diagrams. Rs ri VS VC 1 kΩ MAX Driving Source† TLC548/9 VI VI = Input Voltage at ANALOG IN VS = External Driving Source Voltage Rs = Source Resistance ri = Input Resistance Ci = Input Capacitance † Driving source requirements: • Noise and distortion for the source must be equivalent to the resolution of the converter. • Rs must be real at the input frequency. Ci 55 pF MAX Figure 2. Equivalent Input Circuit Including the Driving Source TLC548C, TLC548I, TLC549C, TLC549I 8-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL SLAS067B – NOVEMBER 1983 – REVISED MAY 1996 8 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251–1443 PRINCIPLES OF OPERATION The TLC548 and TLC549 are each complete data acquisition systems on a single chip. Each contains an internal system clock, sample-and-hold function, 8-bit A/D converter, data register, and control logic circuitry. For flexibility and access speed, there are two control inputs: I/O CLOCK and chip select (CS). These control inputs and a TTL-compatible 3-state output facilitate serial communications with a microprocessor or minicomputer. A conversion can be completed in 17 µs or less, while complete input-conversion-output cycles can be repeated in 22 µs for the TLC548 and in 25 µs for the TLC549. The internal system clock and I/O CLOCK are used independently and do not require any special speed or phase relationships between them. This independence simplifies the hardware and software control tasks for the device. Due to this independence and the internal generation of the system clock, the control hardware and software need only be concerned with reading the previous conversion result and starting the conversion by using the I/O clock. In this manner, the internal system clock drives the “conversion crunching” circuitry so that the control hardware and software need not be concerned with this task. When CS is high, DATA OUT is in a high-impedance condition and I/O CLOCK is disabled. This CS control function allows I/O CLOCK to share the same control logic point with its counterpart terminal when additional TLC548 and TLC549 devices are used. This also serves to minimize the required control logic terminals when using multiple TLC548 and TLC549 devices. The control sequence has been designed to minimize the time and effort required to initiate conversion and obtain the conversion result. A normal control sequence is: 1. CS is brought low. To minimize errors caused by noise at CS, the internal circuitry waits for two rising edges and then a falling edge of the internal system clock after a CS↓ before the transition is recognized. However, upon a CS rising edge, DATA OUT goes to a high-impedance state within the specified tdis even though the rest of the integrated circuitry does not recognize the transition until the specified tsu(CS) has elapsed. This technique protects the device against noise when used in a noisy environment. The most significant bit (MSB) of the previous conversion result initially appears on DATA OUT when CS goes low. 2. The falling edges of the first four I/O CLOCK cycles shift out the second, third, fourth, and fifth most significant bits of the previous conversion result. The on-chip sample-and-hold function begins sampling the analog input after the fourth high-to-low transition of I/O CLOCK. The sampling operation basically involves the charging of internal capacitors to the level of the analog input voltage. 3. Three more I/O CLOCK cycles are then applied to the I/O CLOCK terminal and the sixth, seventh, and eighth conversion bits are shifted out on the falling edges of these clock cycles. 4. The final (the eighth) clock cycle is applied to I/O CLOCK. The on-chip sample-and-hold function begins the hold operation upon the high-to-low transition of this clock cycle. The hold function continues for the next four internal system clock cycles, after which the holding function terminates and the conversion is performed during the next 32 system clock cycles, giving a total of 36 cycles. After the eighth I/O CLOCK cycle, CS must go high or the I/O clock must remain low for at least 36 internal system clock cycles to allow for the completion of the hold and conversion functions. CS can be kept low during periods of multiple conversion. When keeping CS low during periods of multiple conversion, special care must be exercised to prevent noise glitches on the I/O CLOCK line. If glitches occur on I/O CLOCK, the I/O sequence between the microprocessor/controller and the device loses synchronization. When CS is taken high, it must remain high until the end of conversion. Otherwise, a valid high-to-low transition of CS causes a reset condition, which aborts the conversion in progress. A new conversion may be started and the ongoing conversion simultaneously aborted by performing steps 1 through 4 before the 36 internal system clock cycles occur. Such action yields the conversion result of the previous conversion and not the ongoing conversion. TLC548C, TLC548I, TLC549C, TLC549I 8-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL SLAS067B – NOVEMBER 1983 – REVISED MAY 1996 9POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251–1443 PRINCIPLES OF OPERATION F
本文档为【TLC549 datasheet】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_339757
暂无简介~
格式:pdf
大小:200KB
软件:PDF阅读器
页数:10
分类:互联网
上传时间:2010-12-19
浏览量:39