首页 电池PEHJ0073-02

电池PEHJ0073-02

举报
开通vip

电池PEHJ0073-02 Cat® Batteries Cat® Batteries—Greater Starting Power—Lower Maintenance— Longer Life Cat® Premium High Output (PHO) batteries are used in all Caterpillar® Machines and Engine Gen-Sets. They are designed to meet stringent Caterpillar design specifications, ...

电池PEHJ0073-02
Cat® Batteries Cat® Batteries—Greater Starting Power—Lower Maintenance— Longer Life Cat® Premium High Output (PHO) batteries are used in all Caterpillar® Machines and Engine Gen-Sets. They are designed to meet stringent Caterpillar design specifications, which provide industry leading cold cranking amp (CCA) capability and maximum vibration resistance. Maintenance Free or low maintenance designs are available in wet and dry configurations. General Service Line batteries are available in Maintenance Free or low maintenance designs and in wet or dry configurations. Wide selections of BCI group sizes are available for automotive, light truck, bus, industrial, agricultural, marine, recreational and valve regulated (VRLA-AGM & Gel) applications. Cat® Batteries Cat® General Service Batteries—Available Worldwide World’s Toughest Batteries 2 3 Premium High Output —Maximum Vibration Resistance • Vibration Resistance...five times the Industry Standard • Exclusive “flat top” BCI group 4D & 8D batteries are Maintenance Free and have the industries highest cold cranking amps (CCA) • Popular BCI group 31 Maintenance Free batteries with industry leading cold cranking amps...up to 1000 (CCA), for electric power, machine or on-highway truck and bus applications. Deep cycle models are available for truck, marine or recreational usage BCI Cold Reserve Amp Hr. Add Water Nominal Group Cranking Capacity Capacity Maintenance Acid to Fill Size Part No. Amps” Minutes’ Volts @ 20 Hrs. Construction Check Hours Length In (mm) Width In (mm) Height In (mm) Wet Lb (kg) Dry Lb (kg) Qt (liter) 8D 153-5720 1500 465 12 210 C MF 20.47 (520) 10.8 (275) 9.76 (248) 132 (60) – – 8D 101-4000 1400 400 12 190 LAC+ 1000 20.7 (526.5) 10.96 (278) 9.76 (248) 132 (60) 86 (39) 18.0 (17.0) 4D 153-5710 1400 425 12 200 C MF 20.47 (520) 8.58 (218) 9.76 (248) 119 (54) – – 4D 153-5700 1125 305 12 145 C MF 20.47 (520) 8.58 (218) 9.76 (248) 101 (46) – – 4D 9X-9730 1300 400 12 190 LAC+ 1000 20.75 (527) 8.58 (218) 9.76 (248) 119 (54) 81 (37) 14.8 (14.0) 4D 9X-9720 1000 275 12 140 LAC+ 1000 20.75 (527) 8.58 (218) 9.76 (248) 101 (46) 59 (27) 15.9 (15.0) 31 175-4390 1000 180 12 90 C/S MFA 12.9 (328.4) 6.74 (171.2) 9.29 (236) 60 (27) – – 31 175-4370 825 190 12 100 C/S** MFA 12.9 (328.4) 6.74 (171.2) 9.29 (236) 60 (27) – – 31 175-4360 710 185 12 100 C/S*** MFA 12.9 (328.4) 6.74 (171.2) 9.29 (236) 60 (27) – – 31 250-0480 710 185 12 100 C/SDT*** MF 12.9 (328.4) 6.74 (171.2) 9.29 (236) 60 (27) – – 31 115-2422 1000 170 12 90 C SAE MFA 12.9 (328.4) 6.74 (171.2) 9.46 (240.3) 60 (27) – – 31 115-2421 950 170 12 90 C SAE + MFA 12.9 (328.4) 6.74 (171.2) 9.46 (240.3) 60 (27) 44 (20) 6.6 (6.2) 31 9X-3404 950 165 12 100 C SAE MF 13 (330.2) 6.77 (172) 9.46 (240.3) 58 (26) – – 31 3T-5760 750 165 12 100 C SAE MF 13 (330.2) 6.77 (172) 9.46 (240.3) 55 (25) – – 24 153-5656 650 110 12 52 SC MF 10.98 (278.9) 6.85 (174) 9.0 (229.1) 39 (18) – – 65 230-6368 880 140 12 80 SC MF 11.9 (303.4) 7.5 (190.8) 7.5 (191.4) 45.5 (21) – – 74 153-5660 650 110 12 52 SC* MF 10.98 (278.9) 7.0 (178.2) 8.15 (206.9) 39 (18) – – 58 175-4280 500 70 12 35 SC MF 9.96 (253.1) 7.2 (182.5) 6.9 (176) 31 (14) – – 2 153-5690 765 210 6 90 LAC+ 1000 10.24 (260) 6.8 (173) 8.72 (221.6) 37 (17) 22 (10) 4.8 (4.5) Construction Notes: LAC = Low Maintenance, Hybrid Construction C=Calcium Lead Alloy Grid Design MF=Maintenance Free MFA=Maintenance Free with Accessible Vent Caps S = Stud Terminals + = Shipped Dry Only * = Side Terminals ** = Starting and Deep Cycle Battery *** = Deep Cycle and Starting Battery " = For 30 seconds at 0º F (-18º C) ' = Minimum of 25 amp output at 80º F (27º C) SAE = Uses SAE Posts SDT = Dual, Top mounted Terminals, Stud and SAE Post, Marine Deep Cycle/Starting Battery SC=Silver (Ag) Calcium Alloy Grids for resistance to high underhood temperatures BCI Overall Dimensions Nominal Weight Rugged Design–Built Tough–Reliable Starting • Positive and negative plates are anchored to container bottom and locked at the top of celnelement for maximum vibration resistance. • Heavy-duty forged terminal post bushings provide maximum strength and resistance to acid seepage. • Hefty full-frame grids, no sharp edges, optimum acid/paste combination provides better charge acceptance after deep discharge. • Manifold vented cover with built-in Flame Arrestor…a safety feature that directs corrosive gases away from the battery and hold-downs. • Thick, robust container resists rugged treatment typical of heavy-duty commercial use. Embossed part number & descriptors for easy serviceability. Specifications for Cat Premium High Output Batteries-Available Worldwide Wet Batteries BCI Cold Reserve Amp Hr. Group Cranking Capacity Capacity Length Width Height Wet Lb Size Part No. Amps” Minutes’ Volts @ 20 Hrs. Construction In (mm) In (mm) In (mm) (kg) Truck/Agricultural/Industrial 1 8C-3617 650 180 6 100 C/MF 9.0 (229) 6.9 (175) 8.8 (224) 33.5 (15) 2 8C-3629 780 215 6 90 LA 10.4 (264) 6.9 (175) 8.8 (224) 36.5 (17) 3EE 8C-3620 400 95 12 54 LA 19.3 (490) 4.3 (109) 9.0 (229) 43 (20) 3EH 8C-3632 875 250 6 115 LA 19.3 (490) 4.3 (109) 10.0 (254) 47.5 (22) 4 8C-3633 1000 270 6 125 C/MF 12.5 (318) 6.9 (175) 9.5 (241) 47 (21) 4D 8C-3623 900 260 12 115 LA 20.8 (508) 8.5 (216) 10.1 (257) 97 (44) 4DLT 8C-3622 860 250 12 100 LA 20.0 (508) 8.2 (208) 8.2 (208) 79 (36) 7D 8C-3635 950 350 6 156 LA 15.8 (401) 7.0 (178) 9.2 (234) 59.5 (27) 8D 8C-3624 1300 430 12 190 LA 20.7 (526) 11.0 (279) 10.0 (254) 130 (59) 24F 3T-5858 650 120 12 55 SC/MF 10.6 (269) 6.8 (173) 9.0 (229) 40 (18) 27 8C-3601 675 120 12 65 SC/MF 12.0 (305) 6.7 (170) 9.0 (229) 45.5 (21) 27F 8C-3602 675 120 12 65 SC/MF 12.4 (315) 6.7 (170) 9.0 (229) 45.5 (21) 30H 8C-3627 850 180 12 100 C/MF 13.0 (330) 6.8 (173) 9.5 (241) 57.5 (26) 31 8C-3628 800 170 12 80 C/MF/S 13.0 (330) 6.8 (173) 9.5 (241) 54.5 (25) Bus-Special Terminal 8D 250-0473 1450 450 12 190 C/MFA/TB 20.7 (526) 11.0 (279) 10.0 (254) 134 (61) Automotive/Light Truck & SUV 22F 3T-5859 425 65 12 35 SC/MF 9.4 (239) 6.8 (173) 8.3 (211) 29.5 (13) 24 3T-5857 650 120 12 55 SC/MF 10.2 (259) 6.8 (173) 9.0 (229) 38.5 (17) 26 8C-3600 540 80 12 45 SC/MF 8.8 (224) 6.8 (173) 8.0 (203) 24.5 (11) 41 8C-3605 660 110 12 64 SC/MF 11.5 (292) 6.9 (175) 6.9 (175) 37 (17) 42 250-0490 475 70 12 40 SC/MF 9.5 (241) 6.9 (175) 6.9 (175) 29 (13) 55/56/62 8C-3611 585 95 12 52 SC/MF/DT 8.8 (224) 6.0 (152) 8.5 (216) 33 (15) 58 8C-3612 580 55 12 53 SC/MF 10.0 (254) 7.2 (183) 6.9 (175) 31.5 (14) 75 7X-6100 720 100 12 60 SC/MF * 9.0 (229) 7.0 (178) 7.3 (185) 34.5 (16) 75/86 250-0489 540 85 12 47 SC/MF/DT 9.7 (248) 7 (178) 8.1 (206) ! 32 (15) Automotive/Light Truck & SUV, Severe Service/High Temperature, Silver Lead Alloy Technology 25 250-0488 600 90 12 45 ST/MF 9.1 (230) 6.8 (175) 8.8 (225) 31 (14) 35 250-0487 600 90 12 45 ST/MF 9.1 (230) 6.8 (175) 8.8 (225) 31 (14) 34/78 250-0486 690 100 12 60 ST/MF/DT 10.7 (273) 6.8 (175) 8 (203) ! 39 (18) 65 250-0484 650 105 12 55 ST/MF 12 (304) 7.3 (187) 7.6 (194) 39 (18) BCI Overall Dimensions Nominal Weight Premium Batteries for a Wide Range of Applications Ideal for Automotive, Light Truck, Bus, Marine, Industrial, Agricultural, Stationary Power and Recreational Usage. • Maintenance Free and low maintenance… accessible or sealed • Deep Cycle and Valve Regulated (VRLA) Gelled or Absorbed Glass Mat (AGM) batteries • Hefty full frame grids, no sharp edges. Optimum acid/paste combination provides better charge acceptance after deep discharge • Silver (Ag) Calcium Grids for high temperature automotive usage • Commercial batteries have Anchor Lock elements for vibration resistance • Flame Arrestor Safety Vents to direct corrosive gases away from the battery and hold-downs Construction Notes: LA = Low Maintenance, Low Antimony Grids LAC = Low Maintenance, Hybrid Construction C = Calcium Lead Alloy Grid Design MF = Maintenance Free SC= Silver (Ag) Calcium Alloy Grids-for resistance to high underhood temperatures MFA-Maintenance Free, Calcium Grids, Accessible Vent Caps ST= Silver (Ag) Calcium Alloy Heavy Duty Grids * = Side Terminals S = Stud Terminals DT= Dual Terminal TB = Transit Bus one piece end Terminal. Right end of Battery. 1/2"-13 Steel positive stud 3/8"-16 Steel negative stud " = For 30 seconds at 0º F (-18º C) ‘ = Minimum of 25 amp output at 80º F (27º C) ! For height with removable adapter, add 7/8" (22 mm) Cat® Batteries 4 5 Wet Batteries Continued BCI Cold Reserve Amp Hr. Group Cranking Capacity Capacity Length Width Height Wet Lb Size Part No. Amps” Minutes’ Volts @ 20 Hrs. Construction In (mm) In (mm) In (mm) (kg) Marine-Deep Cycle Capability 24M 8C-3638 650 120 12 55 SC/MF/DT/~ 10.8 (274) 6.8 (173) 9.4 (239) 40 (18) 27M 8C-3639 625 150 12 80 @ /S/DT 12.5 (318) 6.8 (173) 9.4 (239) 49 (22) Lawn & Garden U1 8C-3636 260 32 12 25 C/MF 7.8 (198) 5.1 (130) 7.3 (185) 16.5 (7 Golf Cart/Scissor & High Lifts 75 amps @ 80º F GC-2 8C-3641 115 mins. – 6 215 @ OP 10.3 (262) 7.1 (180) 10.9 (277) 63 (29) Dual Terminal Batteries 24/24F/74 127-0824 930 130 12 63 SC/MF/DT 10.9 (277) 7.0 (178) 9.0 (229) 45 (20) 34/78 127-0826 875 120 12 66 SC/MF/DT 10.8 (274) 6.9 (175) 8.0 (203) ! 41 (19) 75/86 250-0489 540 85 12 47 SC/MF/DT 9.7 (248) 7 (178) 8.1 (206) ! 32 (15) 34/78 250-0486 690 100 12 60 ST/MF/DT 10.7 (273) 6.8 (175) 8 (203) ! 39 (18) Dry Batteries BCI Cold Reserve Amp Hr. Nominal Group Cranking Capacity Capacity Length Width Height Wet Lb Dry Lb Acid to Fill Size Part No. Amps” Minutes’ Volts @ 20 Hrs. Construction In (mm) In (mm) In (mm) (kg) (kg) Qt (liter) Truck/Agricultural/Industrial 1 8T-9734 650 180 6 100 C/MF + 9.0 (229) 6.9 (175) 8.8 (224) 33.5 (15) 17.5 (8) 4.5 (4.3) 3D 8T-9730 1400 675 6 320 LA + 20.4 (518) 8.7 (221) 10.0 (254) 120 (54) 84 (38) 11.0 (10.4) 7D 8T-9731 950 350 12 156 LA + 15.7 (399) 7.0 (178) 9.1 (231) 59.5 (27) 34 (15) 7.5 (7.1) 24F 9X-1382 650 120 12 50 SC/MF + 10.6 (269) 6.8 (173) 9.0 (229) 40 (18) 26 (12) 6.0 (5.7 26 145-4517 540 80 12 48 SC/MF + 8.8 (224) 6.8 (173) 8.0 (203) 29.5 (13) 23 (10) 3.5 (3.3) 26R 145-4518 540 80 12 48 SC/MF + 8.8 (224) 6.8 (173) 8.0 (203) 29.5 (13) 23 (10) 3.5 (3.3) 27 3E-8925 675 120 12 55 SC/MF + 12.0 (305) 6.7 (170) 9.0 (229) 45.5 (21) 29.5 (13) 6.5 (6.2) Automotive/Light Truck 22F 9X-1384 425 65 12 32 SC/MF + 9.4 (239) 6.8 (173) 8.3 (211) 29.5 (13) 18 (8) 4.5 (4.3) 24 9X-1383 650 120 12 50 SC/MF + 10.2 (259) 6.8 (173) 9.0 (229) 40 (18) 26 (12) 6.0 (5.7) Marine/Recreational 8V 8C-3640 980 350 8 175 LA + 20.8 (528) 7.3 (185) 10.6 (269) 90 (41) 60 (27) 11.5 (10.9) BCI Overall Dimensions Nominal Weight Construction Notes: LA = Low Maintenance, Low Antimony Grids LAC = Low Maintenance, Hybrid Construction C = Calcium Lead Alloy Grid Design MF = Maintenance Free MFA= Maintenance Free, Calcium Grids, Accessible Vent Caps ST= Silver (Ag) Calcium Alloy Heavy Duty Grids SC= Silver (Ag) Calcium Alloy Grids-for resistance to high underhood temperatures * = Side Terminals S = Stud Terminals DT=Dual Terminal OP = Offset Post with Horizontal Hole Stainless Steel 5/16" Bolt & Hex Nut " = For 30 seconds at 0º F (-18º C) ' = Minimum of 25 amp output at 80º F (27º C) ! For height with removable adapter, add 7/8" (22 mm) @ = Deep Cycle-Antimony Grids ~ = Marine Starting + = Shipped Dry Only # = Wing Nut for 8C-3638 & 8C-3639 is Part # 3B-0723 Absorbed Glass Mat (AGM) Batteries, Designed for High-rate Uninterruptible Power Supplies (UPS) or Standby Applications Power Discharge Watts Rating in per Cell Amperes For 15 mins. Amp Hour @ For 15 mins. to end voltage 20 hour rate BCI to 1.67 V.P.C. of 1.67 V.P.C. to 1.75 volts Terminal Container Group @ 77º F @ 77 º F per cell @ Normal Length Width Height Height Wet Lb Size Part No. (25º C) (25º C) 77 º F (25º C) Voltage Construction Terminal In (mm) In (mm) In (mm) In (mm) (kg) U1 250-0474 116 62 1.63 12 MF-AGM/VRLA 1 7.71 (196) 5.18 (132) 7.18 (182) 6.18 (157) 24 (11) 45 250-0475 156 84.3 2.75 12 MF-AGM/VRLA 2 8.84 (225) 5.31 (135) 8.7 (221) 8.14 (207) 38.5 (18) 24 250-0476 262 140 3.95 12 MF-AGM/VRLA 2 10.2 (259) 6.8 (173) 9.14 (232) 8.12 (206) 53 (24) 27 250-0477 304 165 4.61 12 MF-AGM/VRLA 2 12.72 (323) 6.8 (173) 8.68 (220) 8.12 (206) 63 (29) 31 250-0478 350 186 5.25 12 MF-AGM/VRLA 3 12.93 (329) 6.75 (171) 8.75 (222) 8.58 (218) 69 (31) 31(A) 250-0479 475 261 6.66 12 MF-AGM/VRLA 3 13.5 (342) 6.77 (172) 11.25 (286) 11.08 (281) 98 (45) 4D(H) 250-0483 624 338 9.91 12 MF-AGM/VRLA 4 21.73 (552) 8.82 (210) 9.34 (237) 8.74 (22) 129 (59) MF-AGM/VRLA = Maintenance Free-Absorbed Glass Mat (AGM) Battery. Battery has Flame Arrestor and is low-pressure self sealing Housed in flame-retardant polypropylene (rated 28 LOI) 12-Volt Monoblocks. (A) = Battery is 2.5 in. (63.5 mm) taller and .57 in (13mm) longer than standard Group 31. (H) = Battery has handles. Sealed Valve-Regulated Lead Acid (VRLA) with electrolyte absorbed in separators consisting of a sponge-like mass of matted glass fibers. Preferred for high-rate performance in uninterruptible power supply (UPS) or standby applications. VPC = Volts per Cell. WPC = Watts per Cell. Ratings conform to IEEE-485 Standards. VRLA batteries use recombination reaction to prevent the escape of hydrogen and oxygen gases normally lost in a flooded lead. acid battery. They are non-spillable, never need watering and should never be opened. AGM batteries have a longer production lead time than regular lead-acid type batteries Important: Alternator and charger instructions: for 12-volt AGM Batteries charge to 14.4 volts but no more than 14.6 volts at 68ºF (20º C) Gelled (GEL) Electrolyte, Marine/Recreational, Deep Cycle Capability BCI Cold Reserve Amp Hr. Group Cranking Capacity Capacity Length Width Height Wet Lb Size Part No. Amps” Minutes’ Volts @20 Hrs. Construction In (mm) In (mm) In (mm) (kg) 4D 152-8006 970 375 12 183 MF-G/VRLA 20.8 (528) 8.5 (216) 10 (254) 129.8 (59) 8D 152-7242 1150 475 12 225 MF-G/VRLA 20.8 (528) 11.1 (282) 10 (254) 160.8 (73) Marine Cranking Amps (MCA) = cold cranking Amps divided by 0.8 MF-G/VRLA = Maintenance Free Gel Battery. Sealed, Valve-Regulated Lead Acid (VRLA) battery with gelled electrolyte. Starting/Deep Cycle Marine or Recreational Use Battery. Could be used for Gen-Sets or UPS type applications requiring a sealed battery. VRLA batteries use recombination reaction to prevent the escape of hydrogen and oxygen gases normally lost in a flooded lead acid battery. They are non-spillable, never need watering and should never be opened. " = For 30 seconds at 0º F (-18º C) ' = Minimum of 25 amp output at 80º F (27º C) BCI Overall Dimensions Nominal Weight 1-BCI Group U1 2-BCI Groups 45, 24, 27 3-BCI Group 31 4-BCI Group UL Recognized Component Terminals 1 = Lead terminal. L shaped. Terminals have square holes. 2 = Lead terminal with brass inserts. 1/4-20 x .25 Deep Female Thread. 3 = Lead terminal with brass inserts. Centerline terminals. 1/4-20 x .25 Deep Female Thread. 4 = End terminals with brass inserts. 1/4-20 (UNC) Female Thread. Ratings conform to IEEE-485 Standards. Valve Regulated AGM Batteries—Terminal Locations Important: Alternator and charger instructions: For 12-volt Gel Batteries charge to 13.8 volts but no more than 14.1 volts at 68º F (20º C) Discharge Ratings VRLA batteries are a UL Recognized Component and are I.C.C.O., I.M.D.E., I.A.T.A., and D.O.T. Air Transportable Approved. BCI Overall Dimensions BCI Overall Dimensions Nominal Weight Nominal Weight Valve Regulated Lead Acid (VRLA) Batteries Cat® General Service Batteries—Available Worldwide (cont.) Cat® Batteries 6 7 Battery Accessories Group 31—Charging Posts for Stud Terminals—Part # 4C-5637 Screw-in Charging Posts for Side Terminals—Part # 4C-5638 Wing Nut—Part # 2B-9498 for Part #’s 175-4390/175-4370/175-4360/8C-3628 Wing Nut—Part # 3B-0723 for Part #’s 8C-3638 and 8C-3639 Digital Battery Analyzer—Part # 177-2330 Battery Load Tester—Part # 4C-4911 Booster Cable 12' (3.66 m)—Part # 4C-4933 Booster Cable 20' (6.00 m)—Part # 4C-4937 Heavy Duty Commercial Fast Charger (110V)—Part # 4C-4921 Heavy Duty Commercial Fast Charger (220V)—Part # 4C-4910 Note: Ratings and Part Numbers are subject to change without notice. Cat Premium High Output Batteries — Built Tough to Exceed Demanding Performance Test Requirements: 100 hour Vibration Testing – Five Times the Industry Standard • Battery must be able to withstand vibration forces without suffering mechanical damage, loss of capacity, loss of electrolyte or without developing internal/external leaks • Battery must pass a high rate discharge test after the vibration testing Five 72-hour Deep Discharge/Recharge Test Cycles • Battery must recover to 25 charging amps within 20 minutes and meet Industry Electrical Performance Standards 30 Day Complete Discharge Test • Battery must recover to 25 charging amps within 60 minutes and meet Industry Electrical Performance Standards after recharging SAE J2185 Life Cycle Test • Battery subject to deeper discharge and charge cycles at extreme temperatures not normally encountered in starting a machine or vehicle Cold Soak Test • Battery cold soaked at sub-freezing temperatures and then tested by starting an equally cold engine Recycle all scrap batteries. We accept lead-acid batteries for recycling. Marine Commercial Vessels Maintenance Free 4D, 8D and Group 31 Batteries. General Service Line Line valve regulated (VRLA) Gel batteries. High Marine Cranking Amps (MCA) and Deep Cycling capabilities. Automotive-Truck-Bus & RV A wide selection of popular BCI group sizes. Maintenance Free, Severe Service and Deep Cycle models. Application Specific Group 31 Truck Batteries. Commercial & Recreational A wide selection of premium batteries in most BCI group sizes for light commercial, recreational, agricultural and industrial applications. Marine Pleasure Craft Premium High Output BCI Group 31, Dual Terminal Deep Cycle Batteries. General Service Line BCI group 24M, 27M and 8V sizes. Electric Power Generation Premium High Output Maintenance Free and Accessible batteries in BCI group 4D, 8D, & 31 sizes. High Cold Cranking Amp (CCA) Capability. General Service Line valve regulated (VRLA) GM batteries for UPS or stationary power applications. Construction & Mining Premium High Output Maintenance Free batteries. BCI group 4D, 8D and 31 Sizes. Industry leading cold cranking amps (CCA) and maximum vibration resistance. BCI Terminal Locations GP 2E 3 EH 4EH GP 3EE & 3ET GP 4DLT GP 4D 6D 8D 4B GP 31 28 GP21R, 22R, 22F, 22HF, 22NF, 24F, 24R, 26R, 27F, 27R, 33, 34R, 35, 36R, 47, 48,49, 51R, 54, 55, 56, 58R, 85, U1R(L), 22NL, 29 HR, 30HR, 27 HF, 29NF 6-Volt GP 1,2,3,4 5D, 7D, GC2, GC2H, 3D, 17 HF, 19L GP 40R, 4
本文档为【电池PEHJ0073-02】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_497357
暂无简介~
格式:pdf
大小:456KB
软件:PDF阅读器
页数:0
分类:金融/投资/证券
上传时间:2010-11-27
浏览量:4